This paper describes a modified Sagnac interferometer with a self-referenced polarization and phase-shifting technique for real-time thickness measurement of single- and double-layer transparent thin films. The proposed interferometric setup generated outstanding rotating linearly polarized light with a degree of polarization (DOP) of 99.40%. A beam splitter placed at the interferometer output separated the beam into two identical linearly polarized beams. One of the beams served as a reference, while the other served as a sensing arm. The output linear polarizer set at 45° relative to a reference plane was positioned anterior to the photodetectors to get rotating light intensities for phase shift measurement; hence, the intensities at various polarizations of 0°, 45°, and 90° were automatically acquired without any polarizing device adjustments. These intensities were then transformed into a phase retardation introduced by a sample, and the resulting phase shift was eventually converted into film thickness. The samples were properly prepared, with pure BK7 substrate being deposited by -, -, and / films of known thicknesses. The thickness measurement obtained from the proposed system yielded reading errors of 1.3%, 0.2%, and 1.3/2.5% for -, -, and / films, respectively. The mathematical theory was effectively demonstrated and empirically confirmed. The experimental results show that the proposed setup has a lot of potential for real-time, non-destructive thickness assessment of transparent thin films without the need to modify polarizing device orientations.
This paper presents the comparison of three-, four- and five-step techniques for measuring transparent thin-film thickness of and deposited on BK-7 substrates. The Sagnac interferometer was modified with phase shifting approach for the determination of thin-film thickness. The input light beam was split into reference and testing beams. Before the output light reaching the balanced photodetectors, the real-time signal detection was performed to obtain the output intensities of both beams using three-, four-, and five-polarization settings of an analyzer. The thicknesses could then be efficiently translated from the measured intensities. Thicknesses from three-, four- and five-stepping algorithms were compared with ones from the conventional FE-SEM measurement, and it was discovered that the former performed better with less errors. The findings show that the phase-shifting technique using three-polarization settings is more suitable for the thickness measurement of the transparent thin film.
The application of the polarizing triangular cyclic interferometer to distinguish different types of polarizing components is investigated. The distinct output signals from polarizer and wave plates under examination can clearly be observed.