Yuttapong Jiraraksopakun

Mr. Yuttapong Jiraraksopakun

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2023 in Materials Today Communications
Verified
Journal Article
Closed access
SSShuaibu Sani
Shuaibu Sani
AUABDULLAHI USMAN
ABDULLAHI USMAN
ABApichai Bhatranand
Apichai Bhatranand
YJYuttapong Jiraraksopakun
Yuttapong Jiraraksopakun
KMKhalid Sabo Muhammad
Khalid Sabo Muhammad
UYUsman Yahaya
Usman Yahaya

24 November 2021 in Photonics
Verified
Journal Article
Open access
PDF file
AUABDULLAHI USMAN
ABDULLAHI USMAN
ABApichai Bhatranand
Apichai Bhatranand
YJYuttapong Jiraraksopakun
Yuttapong Jiraraksopakun
RKRapeepan Kaewon
Rapeepan Kaewon
CPChutchai Pawong
Chutchai Pawong
This paper describes a modified Sagnac interferometer with a self-referenced polarization and phase-shifting technique for real-time thickness measurement of single- and double-layer transparent thin films. The proposed interferometric setup generated outstanding rotating linearly polarized light with a degree of polarization (DOP) of 99.40%. A beam splitter placed at the interferometer output separated the beam into two identical linearly polarized beams. One of the beams served as a reference, while the other served as a sensing arm. The output linear polarizer set at 45° relative to a reference plane was positioned anterior to the photodetectors to get rotating light intensities for phase shift measurement; hence, the intensities at various polarizations of 0°, 45°, and 90° were automatically acquired without any polarizing device adjustments. These intensities were then transformed into a phase retardation introduced by a sample, and the resulting phase shift was eventually converted into film thickness. The samples were properly prepared, with pure BK7 substrate being deposited by WO3-, Ta2O5-, and WO3/Ta2O5 films of known thicknesses. The thickness measurement obtained from the proposed system yielded reading errors of 1.3%, 0.2%, and 1.3/2.5% for WO3-, Ta2O5-, and WO3/Ta2O5 films, respectively. The mathematical theory was effectively demonstrated and empirically confirmed. The experimental results show that the proposed setup has a lot of potential for real-time, non-destructive thickness assessment of transparent thin films without the need to modify polarizing device orientations.

29 January 2024 in Applied Optics
Verified
Journal Article
Closed access
PDF file
AUABDULLAHI USMAN
ABDULLAHI USMAN
ABApichai Bhatranand
Apichai Bhatranand
YJYuttapong Jiraraksopakun
Yuttapong Jiraraksopakun
KMKhalid Sabo Muhammad
Khalid Sabo Muhammad
PBPrathan Buranasiri
Prathan Buranasiri
This work has implemented a diverse modification of the Sagnac interferometer to accommodate various measurement requirements, including phase shifting, pattern recognition, and a morphological analysis. These modifications were introduced to validate the adaptability and versatility of the system. To enable phase shifting using the multiple light reflection technique, a half-wave plate (HWP) was utilized with rotations at 0, π/8, π/4, and 3π/8 radians, generating four interference patterns. It is possible to observe a distinct circular fringe width as the polarized light experiences diffraction at the interferometer’s output as it travels through a circular aperture with various diameters ranging from 0.4 to 1 mm. Further modifications were made to the setup by inserting a pure glass and a fluoride-doped tin oxide (FTO) transparent substrate into the common path. This modification aimed to detect and analyze a horizontal fringe pattern. Subsequently, the FTO substrate was replaced with a bee leg to facilitate morphology recognition. A deep learning-based image processing technique was employed to analyze the bee leg morphology. The experimental results showed that the proposed scheme succeeded in achieving the phase shift, measuring hole diameters with errors smaller than 1.6%, separating distinct transparent crystals, and acquiring the morphological view of a bee’s leg. The method also has successfully achieved an accurate surface area and background segmentation with an accuracy over 87%. Overall, the outcomes demonstrated the potential of proposed interferometers for various applications, and the advantages of the optical sensors were highlighted, particularly in microscopic applications.

17 November 2022 in Laser Physics
Verified
Journal Article
Closed access
AUABDULLAHI USMAN
ABDULLAHI USMAN
YJYuttapong Jiraraksopakun
Yuttapong Jiraraksopakun
RKRapeepan Kaewon
Rapeepan Kaewon
CPChutchai Pawong
Chutchai Pawong
ABApichai Bhatranand
Apichai Bhatranand
This paper presents the comparison of three-, four- and five-step techniques for measuring transparent thin-film thickness of T a 2 O 5 and W O 3 deposited on BK-7 substrates. The Sagnac interferometer was modified with phase shifting approach for the determination of thin-film thickness. The input light beam was split into reference and testing beams. Before the output light reaching the balanced photodetectors, the real-time signal detection was performed to obtain the output intensities of both beams using three-, four-, and five-polarization settings of an analyzer. The thicknesses could then be efficiently translated from the measured intensities. Thicknesses from three-, four- and five-stepping algorithms were compared with ones from the conventional FE-SEM measurement, and it was discovered that the former performed better with less errors. The findings show that the phase-shifting technique using three-polarization settings is more suitable for the thickness measurement of the transparent thin film.

3 April 2024 in Applied Optics
Verified
Journal Article
Closed access
AUABDULLAHI USMAN
ABDULLAHI USMAN
ABApichai Bhatranand
Apichai Bhatranand
YJYuttapong Jiraraksopakun
Yuttapong Jiraraksopakun
KMKhalid Sabo Muhammad
Khalid Sabo Muhammad
PBPrathan Buranasiri
Prathan Buranasiri
This work aims to utilize a phase-shifting technique in a rectangular-type Sagnac interferometer (RTSI) to measure the thickness of a thin film of nickel (II) oxide (NiO) in an electron transport layer (ETL) in perovskite solar cell preparation. The NiO layer is deposited on a fluorine-doped tin oxide (FTO) glass substrate. In the RTSI setup, the signal output from the interferometer is divided into the reference and testing arms using a nonpolarizing beam splitter (NPBS). The balanced photodetectors then detect the signal, with the FTO/NiO layer placed in the testing arm and pure FTO in the reference arm. By analyzing the signal intensities at polarization settings of 0° to 180°, the phase shift and thickness of the NiO layer can be determined. The thickness values of FTO and NiO films obtained through three different phase-shifting algorithms of three-, four-, and five-steps are calculated. The obtained NiO thickness values are validated against scanning electron microscopy (SEM). Finally, by considering the NiO thickness value that exhibits the lowest percentage error compared to one from SEM, it is confirmed that the three-step algorithm is the most suitable scheme for obtaining intensities at 0°, 45°, and 90°. Therefore, the proposed setup shows promise as a replacement for SEM in thickness measurements.

8 May 2026 in BioMedInformatics
Verified
Journal Article
Open access
PDF file
SAShamsudeen Abdullahi
Shamsudeen Abdullahi
YJYuttapong Jiraraksopakun
Yuttapong Jiraraksopakun
ABApichai Bhatranand
Apichai Bhatranand
AMAnita Manassakorn
Anita Manassakorn
SCSunee Chansangpetch
Sunee Chansangpetch
VTVisanee Tantisevi
Visanee Tantisevi
Glaucoma is a chronic progressive optic neuropathy causing irreversible blindness globally, underscoring the need for reliable diagnostic tools. While visual field (VF) testing remains the clinical standard, it has significant limitations, including subjective variability and patient cooperation difficulties. Optical coherence tomography (OCT) offers objective structural assessment. Recent deep learning approaches for VF prediction from OCT data can achieve high accuracy, but require raw three-dimensional volumetric data and substantial computational infrastructure that limit their deployment in routine clinical practice. We developed a lightweight convolutional neural network that predicts VF sensitivity from standard two-dimensional OCT thickness maps routinely available in clinical settings. The architecture integrates multiscale depthwise separable convolutions with attention mechanisms and employs an Exponentially Weighted Mean Squared Error loss function to enhance accuracy in clinically critical low-sensitivity regions. Using data from 241 subjects with five-fold cross-validation, our model achieved mean absolute error of 3.32 ± 2.35 dB and correlation of 0.74. This approach addresses the practical deployment limitations of existing methods while maintaining competitive accuracy, enabling implementation in resource-constrained clinical settings for patients who cannot reliably perform standard perimetry.