Bengt K. Lind

Bengt K. Lind

Auto-generated profile, based on publicly available information

Bengt K. Lind

Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm S-17176, Sweden

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 1995 in Medical Physics
Verified
Journal Article
Closed access
AGAnders Gustafsson
Anders Gustafsson
BLBengt K. Lind
Bengt K. Lind
RSRoger Svensson
Roger Svensson
Anders BrahmeAnders Brahme
Anders Brahme

18 May 2011 in Cancers
Verified
Journal Article
Open access
PDF file
MAMagdalena Adamus-Górka
Magdalena Adamus-Górka
PMPanayiotis Mavroidis
Panayiotis Mavroidis
BLBengt K. Lind
Bengt K. Lind
Anders BrahmeAnders Brahme
Anders Brahme
Seven different radiobiological dose-response models have been compared with regard to their ability to describe experimental data. The first four models, namely the critical volume, the relative seriality, the inverse tumor and the critical element models are mainly based on cell survival biology. The other three models: the Lyman (Gaussian distribution), the parallel architecture and the Weibull distribution models are semi-empirical and rather based on statistical distributions. The maximum likelihood estimation was used to fit the models to experimental data and the χ2-distribution, AIC criterion and F-test were applied to compare the goodness-of-fit of the models. The comparison was performed using experimental data for rat spinal cord injury. Both the shape of the dose-response curve and the ability of handling the volume dependence were separately compared for each model. All the models were found to be acceptable in describing the present experimental dataset (p > 0.05). For the white matter necrosis dataset, the Weibull and Lyman models were clearly superior to the other models, whereas for the vascular damage case, the Relative Seriality model seems to have the best performance although the Critical volume, Inverse tumor, Critical element and Parallel architecture models gave similar results. Although the differences between many of the investigated models are rather small, they still may be of importance in indicating the advantages and limitations of each particular model. It appears that most of the models have favorable properties for describing dose-response data, which indicates that they may be suitable to be used in biologically optimized intensity modulated radiation therapy planning, provided a proper estimation of their radiobiological parameters had been performed for every tissue and clinical endpoint.

3 July 2002 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PMPanayiotis Mavroidis
Panayiotis Mavroidis
KTKyriaki Theodorou
Kyriaki Theodorou
DLDimitrios Lefkopoulos
Dimitrios Lefkopoulos
FNFranccedilois Nataf
Franccedilois Nataf
MSMichel Schlienger
Michel Schlienger
Anders BrahmeAnders Brahme
Anders Brahme
This study was carried out in order to derive the radiobiological parameters of the dose-response relation for the obliteration of arteriovenous malformation (AVM) following single fraction stereotactic radiotherapy. Furthermore, the accuracy by which the linear Poisson model predicts the probability of obliteration and how the haemorrhage history, location and volume of the AVM influence its radiosensitivity are investigated. The study patient material consists of 85 patients who received radiation for AVM therapy. Radiation-induced AVM obliterations were assessed on the basis of post-irradiation angiographies and other radiological findings. For each patient the dose delivered to the clinical target volume and the clinical treatment outcome were available. These data were used in a maximum likelihood analysis to calculate the best estimates of the parameters of the linear Poisson model. The uncertainties of these parameters were also calculated and their individual influence on the dose-response curve was studied. AVM radiosensitivity was assumed to be the same for all the patients. The radiobiological model used was proved suitable for predicting the treatment outcome pattern of the studied patient material. The radiobiological parameters of the model were calculated for different AVM locations, bleeding histories and AVM sizes. The range of parameter variability had considerable effect on the dose-response curve of AVM. The correlation between the dosimetric data and their corresponding clinical effect could be accurately modelled using the linear Poisson model. The derived response parameters can be introduced into the clinical routine with the calculated accuracy assuming the same methodology in target definition and delineation. The known volume dependence of AVM radiosensitivity was confirmed. Moreover, a trend relating AVM location with its radiosensitivity was observed.

22 October 2007 in Physica Medica
Verified
Journal Article
Closed access
PDF file
BLBengt K. Lind
Bengt K. Lind
ABAnders Brahme
Anders Brahme

27 February 2010 in Radiation and Environmental Biophysics
Verified
Journal Article
Closed access
PDF file
ABAnders Brahme
Anders Brahme
BLBengt K. Lind
Bengt K. Lind

9 April 2013 in International Journal of Oncology
Verified
Journal Article
Closed access
NMNikos Makris
Nikos Makris
MEMargareta Edgren
Margareta Edgren
PMPanayiotis Mavroidis
Panayiotis Mavroidis
BLBengt K. Lind
Bengt K. Lind
Spandidos Publications is a scientific publisher with a long-standing international reputation for excellent standards and high quality science publications