Onyinyechi Vivian Uhuo

Onyinyechi Vivian Uhuo

Auto-generated profile, based on publicly available information

Onyinyechi Vivian Uhuo

SensorLab (University of the Western Cape Sensor Laboratories), Chemical Sciences Building, University of the Western Cape, Bellville 7535, Cape Town, South Africa

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 September 2022 in The Analyst
Verified
Journal Article
Closed access
PDF file
MOMarlon Oranzie
Marlon Oranzie
SDSamantha F. Douman
Samantha F. Douman
OUOnyinyechi V. Uhuo
Onyinyechi V. Uhuo
KMKefilwe V. Mokwebo
Kefilwe V. Mokwebo
NSNelia Sanga
Nelia Sanga
EIEmmanuel Iwuoha
Emmanuel Iwuoha
This study is a first-time report of the development of a mercaptosuccinic acid-nickel selenide quantum dots (MSA-NiSe2 QDs)-based electrochemical aptasensor for brain natriuretic peptide (BNP) detection. Herein, novel MSA-NiSe2 QDs were synthesized by microwave irradiation. Microscopic and structural analysis revealed that the QDs are spherical with an average diameter of 2 nm. In the presence of the as-prepared QDs, an amine-modified DNA aptamer sequence was attached to a disposable sensing interface through 1-ethyl-3-(3-dimenthylaminopropyl) carbodiimide/N-hydroxysuccinimide coupling chemistries. Electroanalytical analysis revealed that the developed QDs-based electrochemical aptasensor is highly selective towards BNP and successfully detected BNP in both physiological buffer and human plasma samples with detection limits of 5.45 pg mL−1 and 31.95 pg mL−1, respectively. Moreover, the results revealed a 3-fold enhancement in the loading capacity of the BNP aptamer in the presence of MSA-NiSe2 QDs. By taking advantage of the physical and electronic properties of the novel QDs these materials can be easily adapted to other diagnostic approaches.

25 November 2022 in Journal of Alloys and Compounds
Verified
Journal Article
Open access
Sodiq YussufSodiq Yussuf
Sodiq Yussuf
Morongwa RamorokaMorongwa Ramoroka
Morongwa Ramoroka
SMSiyabonga Beizel Mdluli
Siyabonga Beizel Mdluli
Kelechi NwambaekweKelechi Nwambaekwe
Kelechi Nwambaekwe
PEPrecious Idinma Ekwere
Precious Idinma Ekwere
EIEmmanuel Iwuoha
Emmanuel Iwuoha

30 August 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
OUOnyinyechi Vivian Uhuo
Onyinyechi Vivian Uhuo
TWTesfaye Taddese Waryo
Tesfaye Taddese Waryo
SDSamantha Fiona Douman
Samantha Fiona Douman
KJKaylin Januarie
Kaylin Januarie
Kelechi NwambaekweKelechi Nwambaekwe
Kelechi Nwambaekwe
EIEmmanuel Iwuoha
Emmanuel Iwuoha

18 March 2024 in Bioelectrochemistry
Verified
Journal Article
Open access
OUOnyinyechi Uhuo
Onyinyechi Uhuo
TWTesfaye Waryo
Tesfaye Waryo
MOMarlon Oranzie
Marlon Oranzie
NSNelia Sanga
Nelia Sanga
ZLZandile Leve
Zandile Leve
EIEmmanuel Iwuoha
Emmanuel Iwuoha
There has been increasing interest in the use of biosensors for diagnosis of infectious diseases such as tuberculosis (TB) due to their simplicity, affordability, and potential for point-of-care application. The incorporation of aptamer molecules and nanomaterials in biosensor fabrication explores the advantages of high-binding affinity and low immunogenicity of aptamers as well as the high surface-to-volume ratio of nanomaterials, for increased aptasensor performance. In this work, we employed a novel microwave-synthesized copper indium tin sulfide (CITS) substituted-kesterite nanomaterial, together with a natural biopolymer (chitosan), for signal amplification and increased loading of aptamer molecules. Study of the optical properties of CITS nanomaterials showed strong absorption in the UV region characteristic of kesterite semiconductor nanomaterials. X-ray diffraction analysis confirmed the presence of the kesterite phase with average crystallite size of 6.188 nm. Fabrication of interferon-gamma (IFN-γ) TB aptasensor with a chitosan-CITS nanocomposite (χtCITS) increased the aptasensor's electrochemical properties by 77.5 % and improved aptamer loading by 73.7 %. The aptasensor showed excellent sensitivity to IFN-γ concentrations with limit of detection of 6885 fg/mL (405 fM) and linear range of 850-17000 fg/mL (50 - 1000 fM). The aptasensor also exhibited excellent storage and electrochemical stability, with good selectivity towards IFN-γ and possible real sample application.

19 October 2020 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
Candice CupidoCandice Cupido
Candice Cupido
R. Fanelwa AjayiR. Fanelwa Ajayi
R. Fanelwa Ajayi
OUOnyinyechi Uhuo
Onyinyechi Uhuo
KJKaylin Januarie
Kaylin Januarie
EIEmmanuel Iwuoha
Emmanuel Iwuoha

9 January 2023 in Electrochimica Acta
Verified
Journal Article
Closed access
TMTumiso Mabokela
Tumiso Mabokela
Assumpta NwanyaAssumpta Nwanya
Assumpta Nwanya
MNMiranda M Ndipingwi
Miranda M Ndipingwi
Sodiq YussufSodiq Yussuf
Sodiq Yussuf
PEPrecious Idinma Ekwere
Precious Idinma Ekwere
EIEmmanuel Iwuoha
Emmanuel Iwuoha