Mariana Panaitescu

Mariana Panaitescu

Auto-generated profile, based on publicly available information

Mariana Panaitescu

Engineering Sciences in Mechanics and Environment Department, Marine Engineering Faculty, Constanta Maritime University, 104 Mircea cel Bătrân Str, 900663 Constanta, Romania

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2015 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
FPFanel-Viorel Lucian PANAITESCU
Fanel-Viorel Lucian PANAITESCU
FPF-V Panaitescu
F-V Panaitescu
Iulia AntonIulia Anton
Iulia Anton
Purpose of the work: The total cost of a sewage plants is often determined by the present value method. All of the annual operating costs for each process are converted to the value of today's correspondence and added to the costs of investment for each process, which leads to getting the current net value. The operating costs of the sewage plants are subdivided, in general, in the premises of the investment and operating costs. The latter can be stable (normal operation and maintenance, the establishment of power) or variables (chemical and power sludge treatment and disposal, of effluent charges). For the purpose of evaluating the preliminary costs so that an installation can choose between different alternatives in an incipient phase of a project, can be used cost functions. In this paper will be calculated the operational cost to make several scenarios in order to optimize its. Total operational cost (fixed and variable) is dependent global parameters of wastewater treatment plant. Research and methodology: The wastewater treatment plant costs are subdivided in investment and operating costs. We can use different cost functions to estimate fixed and variable operating costs. In this study we have used the statistical formulas for cost functions. The method which was applied to study the impact of the influent characteristics on the costs is economic analysis. Optimization of plant design consist in firstly, to assess the ability of the smallest design to treat the maximum loading rates to a given effluent quality and, secondly, to compare the cost of the two alternatives for average and maximum loading rates. Results: In this paper we obtained the statistical values for the investment cost functions, operational fixed costs and operational variable costs for wastewater treatment plant and its graphical representations. All costs were compared to the net values. Finally we observe that it is more economical to build a larger plant, especially if maximum loading rates are reached. The actual target of operational management is to directly implement the presented cost functions in a software tool, in which the design of a plant and the simulation of its behaviour are evaluated simultaneously.

1 January 2014 in TransNav, the International Journal on Marine Navigation and Safety of Sea Transportation
Verified
Journal Article
Open access
PDF file
FPFanel-Viorel Lucian PANAITESCU
Fanel-Viorel Lucian PANAITESCU
FPFanel-Viorel Lucian PANAITESCU
Fanel-Viorel Lucian PANAITESCU
IVI. Voicu
I. Voicu
IPI.I. Panaitescu
I.I. Panaitescu

3 November 2015 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
FPFanel-Viorel Lucian PANAITESCU
Fanel-Viorel Lucian PANAITESCU
FPFanel-Viorel Lucian PANAITESCU
Fanel-Viorel Lucian PANAITESCU
We present here a successful implementation of the Environmental Management System (EMS) in a shipping company. The EMS of the each company must be revised and expanded and new analytical requirements included in it. This new EMS concept is available to everyone on board and must be studied by every seafarer. All environmental requirements to be strictly followed all over the world. The main points of new EMS are: new open reporting system, environmental tag system (ETS) which introduce non re-usable numbered seals, pollution prevention equipment (OWS, OCM, Incinerator and Sewage Treatment Plant), the environmental defect reports system - extraordinary E/R operations and leakages log book.

14 December 2016
Verified
Conference Paper
Closed access
PDF file
FPFanel-Viorel Panaitescu
Fanel-Viorel Panaitescu
FPFanel-Viorel Lucian PANAITESCU
Fanel-Viorel Lucian PANAITESCU
Iulia AntonIulia Anton
Iulia Anton

1 November 2013 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
FPFanel-Viorel Lucian PANAITESCU
Fanel-Viorel Lucian PANAITESCU
DDDumitru Deleanu
Dumitru Deleanu
FPFanel-Viorel Lucian PANAITESCU
Fanel-Viorel Lucian PANAITESCU
We present data obtained after a 2 years period of monitoring the wave’s parameters in an off-shore location. We have used the location of a working petroleum platform situated at: N44031’, E29034’ at 50 km from land and 80 km NE from Constanta Harbor, in the Romanian Black Sea waters. We describe monitoring systems used.and their solution. The Advanced Doppler Velocymeter (ADV) for parameters of marine waves is based on Doppler effect and it is composed of a transmitter at a frequency of 10 MHz and of 3 receivers which are equidistant from 1200. Data storage on the HDD PC, with the possibility of take-over and normal review (ASCII file). We can get the values of the speed and current division marine tide amplitude and direction of the wave at each measurement, the number of measurements, date, hour, minute and second of measurement, as well as other parameters, both as numeric values and a graph having abscissa registration number. This monitoring, which comprises the period of one year including, reveals an amplitude an annual average of the wave of hmed=1.53 m, obtained by taking maximum envelope appeared in a measurement range of 120 seconds. We compare these off-shore values with the coastal ones and we conclude that the wave’s energetic off-shore potential is unexpectedly bigger that in the coastal region.

22 April 2026 in Sustainability
Verified
Journal Article
Open access
PDF file
FPFanel-Viorel Lucian PANAITESCU
Fanel-Viorel Lucian PANAITESCU
Robert Madalin ChivuRobert Madalin Chivu
Robert Madalin Chivu
MPMariana Panaitescu
Mariana Panaitescu
IVIonut Voicu
Ionut Voicu
The use of renewable energy sources instead of conventional ones, together with the development of efficient electricity storage solutions, represents a central objective of the transition to sustainable and resilient energy systems. In this context, two main development directions are the integration of hydrogen in the energy chain (Power-to-Gas) and the use of batteries, each with specific advantages and disadvantages, compared to internal combustion engines. The purpose of this work was to evaluate the dynamic response time of a hydrogen fuel cell model powered by green hydrogen, under conditions of sudden and instantaneous power demand, for its integration into wind-based renewable energy systems. Experimental research was carried out on an autonomous installation designed to operate continuously for an unlimited duration, simulating the integration of hydrogen produced from wind sources. The novelty consists of the application of an instrumental method for automatic measurement of the response time of a proton exchange membrane hydrogen fuel cell, based on the automatic acquisition and processing of measured electrical signals. The response time of the fuel cell was compared with that of an internal combustion engine based on the classic Carnot cycle, using a dedicated oscilloscope. The load connection time, the current and voltage variation as a function of time were recorded simultaneously. The results show that the response time of the fuel cell is relatively short (approximately 0.3 ms), much lower than that of the internal combustion engine (0.7 s), being of the order of about 2333 times smaller. In conclusion, the hydrogen fuel cell can be effectively integrated into renewable energy systems for the role of an uninterruptible power supply, with an exceptionally fast dynamic response, suitable for applications in regulating and supporting wind-powered networks.