Di Wu

Di Wu

Auto-generated profile, based on publicly available information

Di Wu

The Maersk Mc-Kinney Mller Institute, University of Southern Denmark, Odense, Denmark

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
DWDi Wu
Di Wu
YZYao Zhang
Yao Zhang
MOMouloud Ourak
Mouloud Ourak
KNKenan Niu
Kenan Niu
JDJenny Dankelman
Jenny Dankelman
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
Catheters are increasingly being used to tackle problems in the cardiovascular system. However, positioning precision of the catheter tip is negatively affected by hysteresis. To ensure tissue damage due to imprecise positioning is avoided, hysteresis is to be understood and compensated for. This work investigates the feasibility to model hysteresis with a Long Short-Term Memory (LSTM) network. A bench-top setup containing a catheter distal segment was developed for model evaluation. The LSTM was first tested using four groups of test datasets containing diverse patterns. To compare with the LSTM, a Deadband Rate-Dependent Prandtl-Ishlinskii (DRDPI) model and a Support Vector Regression (SVR) model were established. The results demonstrated that the LSTM is capable of predicting the tip bending angle with sub-degree precision. The LSTM outperformed the DRDPI model and the SVR model by 60.1% and 36.0%, respectively, in arbitrarily varying signals. Next, the LSTM was further validated in a 3D reconstruction experiment using Forward-Looking Optical Coherence Tomography (FL-OCT). The results revealed that the LSTM was able to accurately reconstruct the environment with a reconstruction error below 0.25 mm. Overall, the proposed LSTM enabled precise free-space control of a robotic catheter in the presence of severe hysteresis. The LSTM predicted the catheter tip response precisely based on proximal input pressure, minimizing the need to install sensors at the catheter tip for localization.

14 December 2022 in IEEE Transactions on Robotics
Verified
Journal Article
Closed access
XHXuan Thao Ha
Xuan Thao Ha
DWDi Wu
Di Wu
MOMouloud Ourak
Mouloud Ourak
GBGianni Borghesan
Gianni Borghesan
JDJenny Dankelman
Jenny Dankelman
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
In this article, a deep learning method for the shape sensing of continuum robots based on multicore fiber bragg grating (FBG) fiber is introduced. The proposed method, based on an artificial neural network (ANN), differs from traditional approaches, where accurate shape reconstruction requires a tedious characterization of many characteristic parameters. A further limitation of traditional approaches is that they require either multiple fibers, whose location relative to the centerline must be precisely known (calibrated), or a single multicore fiber whose position typically coincides with the neutral line. The proposed method addresses this limitation and, thus, allows shape sensing based on a single multicore fiber placed off-center. This helps in miniaturizing and leaves the central channel available for other purposes. The proposed approach was compared to a recent state-of-the-art model-based shape sensing approach. A two-degree-of-freedom benchtop fluidics-driven catheter system was built to validate the proposed ANN. The proposed ANN-based shape sensing approach was evaluated on a 40-mm-long steerable continuum robot in both 3-D free-space and 2-D constrained environments, yielding an average shape sensing error of 0.24 and 0.49 mm, respectively. With these results, the superiority of the proposed approach compared to the recent model-based shape sensing method was demonstrated.

27 June 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
DWDi Wu
Di Wu
XHXuan Thao Ha
Xuan Thao Ha
YZYao Zhang
Yao Zhang
MOMouloud Ourak
Mouloud Ourak
GBGianni Borghesan
Gianni Borghesan
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
In cardiovascular interventions, when steering catheters and especially robotic catheters, great care should be paid to prevent applying too large forces on the vessel walls as this could dislodge calcifications, induce scars or even cause perforation. To address this challenge, this paper presents a novel compliant motion control algorithm that relies solely on position sensing of the catheter tip and knowledge of the catheter’s behavior. The proposed algorithm features a data-driven tip position controller. The controller is trained based on a so-called control Long Short-Term Memory Network (control-LSTM). Trajectory following experiments are conducted to validate the quality of the proposed control-LSTM. Results demonstrated superior positioning capability with sub-degree precision of the new approach in the presence of severe rate-dependent hysteresis. Experiments both in a simplified setup as well as in an aortic phantom further show that the proposed approach allows reducing the interaction forces with the environment by around 70%. This work shows how deep learning can be exploited advantageously to avoid tedious modeling that would be needed to precisely steer continuum robots in constrained environments such as the patient’s vasculature.

24 August 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XHXuan Thao Ha
Xuan Thao Ha
MOMouloud Ourak
Mouloud Ourak
OAOmar Al-Ahmad
Omar Al-Ahmad
DWDi Wu
Di Wu
GBGianni Borghesan
Gianni Borghesan
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
Endovascular catheterization is an intervention which offers a low risk alternative to open surgery in many patients. Today’s interventions rely heavily on fluoroscopic imaging to guide interventionalists. Fluoroscopy only produces 2D visualization of the catheter and also exposes both the patient and interventionalists to harmful radiation. Different approaches have been proposed to overcome the limitations of fluoroscopy. Fiber Bragg Grating (FBG)-based shape sensing is becoming popular to reconstruct the catheter shape. Multi-core fibers with parallel optical cores are interesting as they allow 3D shape reconstruction with a single fiber. A common issue with FBG-based shape sensing is its sensitivity to variations in twist. Even small amounts of twist can significantly impact the overall shape reconstruction accuracy. This work proposes a novel approach which combines electromagnetic tracking (EMT), FBG-based shape sensing, and sparse fluoroscopic images. The method provides real-time 3D visualization of the catheter without the need of continuous fluoroscopy. A unique feature of the proposed method is the selective use of imaging for dynamic twist-compensation of the FBG sensor. The proposed sensor-fusion method improved 3D reconstruction accuracy. Real-world in-vitro experiments promising results. For a catheter with an embedded fiber length of 170 mm, the proposed approach the 3D shape with a median root-mean-square (rms) error of 0.39 mm and an interquartile range of 0.10 mm in the 2D experiment in which the catheter was bent in a plane. A median rms error of 0.54 mm and an interquartile range of 0.07 mm were achieved in the 3D experiments.

15 March 2024 in Biomedical Signal Processing and Control
Verified
Journal Article
Open access
DWDi Wu
Di Wu
RZRenchi Zhang
Renchi Zhang
APAmeya Pore
Ameya Pore
DDDiego Dall’ALba
Diego Dall’ALba
XHXuan Thao Ha
Xuan Thao Ha
EPEmmanuel Vander Poorten
Emmanuel Vander Poorten

17 October 2019 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
GLGang Li
Gang Li
NPNiravkumar A. Patel
Niravkumar A. Patel
JHJan Hagemeister
Jan Hagemeister
JYJiawen Yan
Jiawen Yan
DWDi Wu
Di Wu
IIIulian Iordachita
Iulian Iordachita