Representative Publications

View All Publications
22 February 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
DWDi Wu
Di Wu
YZYao Zhang
Yao Zhang
MOMouloud Ourak
Mouloud Ourak
KNKenan Niu
Kenan Niu
JDJenny Dankelman
Jenny Dankelman
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
Catheters are increasingly being used to tackle problems in the cardiovascular system. However, positioning precision of the catheter tip is negatively affected by hysteresis. To ensure tissue damage due to imprecise positioning is avoided, hysteresis is to be understood and compensated for. This work investigates the feasibility to model hysteresis with a Long Short-Term Memory (LSTM) network. A bench-top setup containing a catheter distal segment was developed for model evaluation. The LSTM was first tested using four groups of test datasets containing diverse patterns. To compare with the LSTM, a Deadband Rate-Dependent Prandtl-Ishlinskii (DRDPI) model and a Support Vector Regression (SVR) model were established. The results demonstrated that the LSTM is capable of predicting the tip bending angle with sub-degree precision. The LSTM outperformed the DRDPI model and the SVR model by 60.1% and 36.0%, respectively, in arbitrarily varying signals. Next, the LSTM was further validated in a 3D reconstruction experiment using Forward-Looking Optical Coherence Tomography (FL-OCT). The results revealed that the LSTM was able to accurately reconstruct the environment with a reconstruction error below 0.25 mm. Overall, the proposed LSTM enabled precise free-space control of a robotic catheter in the presence of severe hysteresis. The LSTM predicted the catheter tip response precisely based on proximal input pressure, minimizing the need to install sensors at the catheter tip for localization.

27 June 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
DWDi Wu
Di Wu
XHXuan Thao Ha
Xuan Thao Ha
YZYao Zhang
Yao Zhang
MOMouloud Ourak
Mouloud Ourak
GBGianni Borghesan
Gianni Borghesan
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
In cardiovascular interventions, when steering catheters and especially robotic catheters, great care should be paid to prevent applying too large forces on the vessel walls as this could dislodge calcifications, induce scars or even cause perforation. To address this challenge, this paper presents a novel compliant motion control algorithm that relies solely on position sensing of the catheter tip and knowledge of the catheter’s behavior. The proposed algorithm features a data-driven tip position controller. The controller is trained based on a so-called control Long Short-Term Memory Network (control-LSTM). Trajectory following experiments are conducted to validate the quality of the proposed control-LSTM. Results demonstrated superior positioning capability with sub-degree precision of the new approach in the presence of severe rate-dependent hysteresis. Experiments both in a simplified setup as well as in an aortic phantom further show that the proposed approach allows reducing the interaction forces with the environment by around 70%. This work shows how deep learning can be exploited advantageously to avoid tedious modeling that would be needed to precisely steer continuum robots in constrained environments such as the patient’s vasculature.

25 August 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YZYao Zhang
Yao Zhang
EVEric Verschooten
Eric Verschooten
MOMouloud Ourak
Mouloud Ourak
KAKaat Van Assche
Kaat Van Assche
GBGianni Borghesan
Gianni Borghesan
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
Researchers have developed a large number of methods to study the brain’s function. One of the most effective techniques is in vivo whole-cell patch clamp recording which allows the recording of intracellular neuronal activity. A major issue that drastically reduces the efficiency of in vivo patch clamping is the excessive movement of the brain primarily caused by heartbeat and breathing, which can be larger than the size of the neurons under investigation. Motion compensation techniques are complicated due to the lack of sensors to reliably measure local physiologically-induced motion. This work proposes the use of Electrical Bio-impedance (EBI) to the existing patch electrodes in the patching pipette as a proximity sensor. The study further develops an Extended Kalman Filter (EKF) to estimate overall motion and then establishes a motion compensation algorithm for the patch pipette. The proposed method was developed on a custom lab benchtop setup and validated during actual in vivo experiments. The results of the lab experiments show a real-time compensatory performance exceeding 80%. The in vivo experiments achieved a performance of over 75%, confirming the ability to compensate for real physiologically induced motion. Moreover, the method demonstrated dynamic continuous motion compensation while the electrode was advanced to a neuron, contacting the neuron membrane without damage illustrating the ability to improve neuronal patch clamping. As far as the authors are aware this is the first time that physiologically induced motion can be compensated for this application and this solely relies on EBI.

27 August 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YZYao Zhang
Yao Zhang
MPMartina Polidoro
Martina Polidoro
MOMouloud Ourak
Mouloud Ourak
EVEric Verschooten
Eric Verschooten
JBJohan Bennett
Johan Bennett
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
Percutaneous coronary intervention (PCI) is increasingly utilized for treating chronic total occlusion (CTO) coronary arteries. When direct passage through the occlusion is not feasible, the retrograde “kissing wire technique” (KWT) provides a valuable cannulation alternative. The KWT technique employs two microcatheters: one in the subintimal layer and the other in the true lumen on the opposite side of the occlusion. The latter microcatheter acts as a visual marker to guide the re-entry of the microcatheter located in the subintimal layer toward the true lumen. However, accurately determining the microcatheter’s orientation, which is crucial for ensuring the correct re-entry direction and avoiding the pericardial space, remains a significant challenge. This work presents a new method based on multi-electrical bio-impedance (EBI) sensing and cubic spline interpolation (CSI). The angular range for the correct re-entry orientation was calculated based on the dimensions of the blood vessel and the microcatheters. By measuring the EBI from each electrode around the microcatheter tip, the catheter position is estimated through the minimum EBI, indicating the optimal reentry point. Experiments conducted in pure saline and in vitro conditions demonstrate that the approach reduces errors by over 30% at three distinct roll angles compared to the angular range. Furthermore, experiments across all angles revealed a maximum estimation error approximately 60% lower than the clinical standard. These results indicate significant potential for enhancing the efficacy and reducing the risks of the KWT technique through the EBI-guided approach.

3 February 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YZYao Zhang
Yao Zhang
ZCzhuoqi cheng
zhuoqi cheng
MOMouloud Ourak
Mouloud Ourak
TSThiusius Rajeeth Savarimuthu
Thiusius Rajeeth Savarimuthu
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
Needle-based interventions are routine in clinical practice, yet clinicians lack reliable, precise, real-time estimates of the tip-to-target distance—–a key determinant of safety and efficiency. To bridge this critical clinical gap, physics-based models that maps electrical bio-impedance (EBI) measurements to the absolute tip-to-target distance by leveraging tissue-intrinsic electrical properties encoded in EBI are presented in this work. A tripolar electrode configuration is adopted to ensure tool-independence and broad compatibility across instruments and anatomical sites. The optimal layout of electrode radius, inter-electrode spacing, and placement was identified through a systematic parametric study. The model was validated across finite-element simulations, saline solution experiments, and ex vivo layered tissue. In all settings, proximity distance estimates were accurate and robust across different insertion angles. In simulation, it achieved 0.55 mm RMSE/1.06 mm MAE when the target layer was less conductive than the first layer and 0.40 mm RMSE/1.21 mm MAE when it was more conductive. In saline, four insertion angles yielded millimeter errors with no angle dependence. In ex vivo layered tissue, accuracy remained near the millimeter level across angles (RMSE 1.00–1.13 mm and MAE 1.30–1.58 mm), which is slightly lower than saline yet consistent across orientations. Together, these results establish a general, instrument-agnostic framework for absolute proximity distance sensing during needle interventions with the potential to enhance safety and efficiency in minimally invasive procedures. Furthermore, by first focusing on a two-layer model, this work provides a clear pathway to multi-layer tissue modeling and broader anatomical generalization.

15 December 2025 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
XZXiaohang Zhang
Xiaohang Zhang
DWDi Wu
Di Wu
MTMatthias Tummers
Matthias Tummers
YCYuyu Cai
Yuyu Cai
YZYao Zhang
Yao Zhang
EPEmmanuel Benjamin Vander Poorten
Emmanuel Benjamin Vander Poorten
Open spina bifida (OSB), a congenital anomaly caused by incomplete spinal column closure, leads to progressive nerve damage. While multi-port minimally invasive procedures are being optimized clinically, single-port access (SPA) surgery presents a promising, less invasive alternative. Beyond reducing scarring, SPA may also decrease the risk of iatrogenic preterm premature rupture of membranes and enhance maternal recovery, as suggested by outcomes in other minimally invasive interventions. However, technical challenges persist in SPA implementations, particularly in instrument miniaturization and control precision. To facilitate this approach, a macro-micro multi-arm robotic system is under development. The system features an 11-mm-diameter insertion port to deploy four instrument arms. The arm design incorporates a hybrid backbone structure. A macro proximal section of concentric tubes provides stable deployment, while a micro distal flexible segment enables the dexterous manipulation. This paper presents dedicated modeling and control strategies to address actuator and transmission nonlinearities arising from stringent miniaturization requirements. A hybrid framework combining joint-level feedback with deep-learning-based feedforward compensation mitigates limitations imposed by pneumatic artificial muscles and tendon transmissions. The system is validated through trajectory-following experiments, each conducted over 10 trials. Preliminary results show an average root-mean-squared error of 0.28 mm, an average maximum absolute error of 0.85 mm, and an average standard deviation of 0.18 mm across both trajectories. These results demonstrate consistent sub-millimeter precision, satisfying the requirement for OSB repair. The feasibility of the system was then verified through a phantom study.