Mingjie Sheng

Mingjie Sheng

Auto-generated profile, based on publicly available information

Mingjie Sheng

Research Center for Electromagnetic Environmental Effects, School of Mechanical Engineering, Southeast University 1 , Nanjing 211189

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2020 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
ZZZhongyuan Zhou
Zhongyuan Zhou
PHPeng Hu
Peng Hu
XZXiang Zhou
Xiang Zhou
JJJingkang Ji
Jingkang Ji
MSMingjie Sheng
Mingjie Sheng
QZQi Zhou
Qi Zhou
To evaluate the performance of oscillating wall stirrer (OWS) in reverberation chamber (RC), the number of independent stirrer positions, and field distributions (in lessmoded, undermoded, and overmoded frequency regimes) are discussed in detail in this work. For the estimation of independent stirrer positions, correlation matrix method (CMM), i.e., threshold-dependent correlation matrix defined by Pearson correlation coefficient, is used to determine the number of independent stirrer positions, where experimental comparative analysis between autocorrelation coefficient in IEC 61000-4-21 and CMM is presented, and the corresponding results provide a reasonable explanation for the overestimation of independent stirrer positions. For the field distributions, parameter $M$ in Bessel $K$ distribution, related to the number of excited modes within $Q$ -bandwidth, is adopted to assess the quasiwall-like behavior of OWS in lessmoded, undermoded, and overmoded RCs, respectively, and the results show that OWS can distribute the field energy that was not sufficiently stirred with a higher probability ( $>$ 50%) at undermoded frequencies.

11 September 2019 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
ZZZhongyuan Zhou
Zhongyuan Zhou
PLPeng Li
Peng Li
MSMingjie Sheng
Mingjie Sheng
QZQi Zhou
Qi Zhou
PHPeng Hu
Peng Hu
In this article, a method combining array signal processing and adaptive noise cancellation is proposed to suppress the ambient interferences of in-situ measurement. First, the directions of arrival and classes of all signals are obtained by performing blind source separation and sparse reconstruction on the received signals. Then, the received signals are reused to form two different data channels. In both channels, the interferences that are coherent with the radiated signals of the equipment under test and have larger amplitudes are eliminated based on null trap forming, whereas the coherent interferences with smaller amplitudes are ignored after being attenuated. Besides, the other interferences are suppressed by the adaptive noise cancellation based on their correlation in the two channels. For transient signals, overlapping window technique is used to avoid the losses of the spectrums. Each frame of the signals is cyclically extended to provide sufficient points for adaptive noise cancellation. The proposed method achieves the suppression of multisource ambient interferences with fewer array elements. Simulation and experiment results are given to verify the effectiveness and accuracy of the proposed method.

14 December 2024 in Measurement
Verified
Journal Article
Closed access
MSMingjie Sheng
Mingjie Sheng
ZZZhongyuan Zhou
Zhongyuan Zhou
JRJinjing Ren
Jinjing Ren
YGYixing Gu
Yixing Gu
QZQi Zhou
Qi Zhou
BXBingnan Xing
Bingnan Xing

20 July 2020 in IEEE Microwave and Wireless Components Letters
Verified
Journal Article
Closed access
PHPeng Hu
Peng Hu
ZZZhongyuan Zhou
Zhongyuan Zhou
XZXiang Zhou
Xiang Zhou
JJJingkang Ji
Jingkang Ji
MSMingjie Sheng
Mingjie Sheng
ZQZhou Qi
Zhou Qi
This letter presents a practical method for identifying the resonance frequencies of arbitrary complex cavity within the reverberation chamber (RC). Based on a sufficient set of independent samples, the permutation entropy (PE) algorithm is used to determine the resonance frequency. For this method, the relevant parameters and regularity indicators have been defined, and the corresponding results are verified experimentally from different configurations of unloaded and loaded cavities.

1 November 2019
Verified
Conference Paper
Closed access
LJLi Jinpeng
Li Jinpeng
ZZZhongyuan Zhou
Zhongyuan Zhou
PHPeng Hu
Peng Hu
SMSheng Mingjie
Sheng Mingjie
Considering the influence of the explosive and case of Electro-explosive device (EED) on the radio frequency (RF) induced current on the bridgewire, a new method for calculating the RF induced current of EED is proposed. Firstly, the EED containing the explosive and case is equivalent to a non-uniform transmission line (TML) consisting of three uniform TMLs. Then, with the irradiating of electromagnetic field, each uniform TML can be regareded as the driving source of the bridgewire in the EED. The current response of the bridgewire to each TML is calculated by Agrawal model, and then the total current on the bridgewire is obtained by superposition principle. Finally, two plane waves with different incident angles are used irradiate the EED respectively, and the RF induced current of the EED is calculated by the proposed method, which is in good agreement with CST simulation results. The proposed method is feasible to calculate the RF induced current of EED.

15 March 2023 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
MSMingjie Sheng
Mingjie Sheng
ZZZhongyuan Zhou
Zhongyuan Zhou
JRJinjing Ren
Jinjing Ren
YGYixing Gu
Yixing Gu
YXYang Xiao
Yang Xiao
DPDavid Pommerenke
David Pommerenke
To achieve the transfer impedance measurement of electromagnetic interference (EMI) gaskets, a fixture useful up to 18 GHz is developed based on the SAE ARP1705C standard. The radial size of the coaxial section of the fixture is shaped from the perspective of its characteristic impedance and suppression of higher-order modes. Subsequently, a parametric analysis is performed to examine the sensitivity of critical dimensions, and the study analyzes the key factors affecting the voltage standing wave ratio (VSWR) of the fixture and its 50 $\Omega$ resistor. Based on the preceding analysis, two solutions are proposed to improve the VSWR: reducing the length of the 50 $\Omega$ resistor and modifying the shape of the coaxial outer conductor. The ultimate outcome of the transfer impedance measurement fixture yields a VSWR lower than 2.6:1, up to 18 GHz. The functionality of the fixture is demonstrated through the measurement of two gaskets, showcasing its practical utility in engineering applications.