Jianyang Xie

Jianyang Xie

Auto-generated profile, based on publicly available information

Jianyang Xie

University of Liverpool

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
YMYuhui Ma
Yuhui Ma
HHHuaying Hao
Huaying Hao
JXJianyang Xie
Jianyang Xie
HFHuazhu Fu
Huazhu Fu
JZJiong Zhang
Jiong Zhang
Yifan ZhaoYifan Zhao
Yifan Zhao
Optical Coherence Tomography Angiography (OCTA) is a non-invasive imaging technique that has been increasingly used to image the retinal vasculature at capillary level resolution. However, automated segmentation of retinal vessels in OCTA has been under-studied due to various challenges such as low capillary visibility and high vessel complexity, despite its significance in understanding many vision-related diseases. In addition, there is no publicly available OCTA dataset with manually graded vessels for training and validation of segmentation algorithms. To address these issues, for the first time in the field of retinal image analysis we construct a dedicated Retinal OCTA SEgmentation dataset (ROSE), which consists of 229 OCTA images with vessel annotations at either centerline-level or pixel level. This dataset with the source code has been released for public access to assist researchers in the community in undertaking research in related topics. Secondly, we introduce a novel split-based coarse-to-fine vessel segmentation network for OCTA images (OCTA-Net), with the ability to detect thick and thin vessels separately. In the OCTA-Net, a split-based coarse segmentation module is first utilized to produce a preliminary confidence map of vessels, and a split-based refined segmentation module is then used to optimize the shape/contour of the retinal microvasculature. We perform a thorough evaluation of the state-of-the-art vessel segmentation models and our OCTA-Net on the constructed ROSE dataset. The experimental results demonstrate that our OCTA-Net yields better vessel segmentation performance in OCTA than both traditional and other deep learning methods. In addition, we provide a fractal dimension analysis on the segmented microvasculature, and the statistical analysis demonstrates significant differences between the healthy control and Alzheimer’s Disease group. This consolidates that the analysis of retinal microvasculature may offer a new scheme to study various neurodegenerative diseases.

3 July 2019 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
Yifan ZhaoYifan Zhao
Yifan Zhao
YLYonghuai Liu
Yonghuai Liu
JXJianyang Xie
Jianyang Xie
HZHuaizhong Zhang
Huaizhong Zhang
Yalin ZhengYalin Zheng
Yalin Zheng
JLJiang Liu
Jiang Liu
The estimation of vascular network topology in complex networks is important in understanding the relationship between vascular changes and a wide spectrum of diseases. Automatic classification of the retinal vascular trees into arteries and veins is of direct assistance to the ophthalmologist in terms of diagnosis and treatment of eye disease. However, it is challenging due to their projective ambiguity and subtle changes in appearance, contrast and geometry in the imaging process. In this paper, we propose a novel method that is capable of making the artery/vein (A/V) distinction in retinal color fundus images based on vascular network topological properties. To this end, we adapt the concept of dominant set clustering and formalize the retinal blood vessel topology estimation and the A/V classification as a pairwise clustering problem. The graph is constructed through image segmentation, skeletonization and identification of significant nodes. The edge weight is defined as the inverse Euclidean distance between its two end points in the feature space of intensity, orientation, curvature, diameter, and entropy. The reconstructed vascular network is classified into arteries and veins based on their intensity and morphology. The proposed approach has been applied to five public databases, INSPIRE, IOSTAR, VICAVR, DRIVE and WIDE, and achieved high accuracies of 95.1%, 94.2%, 93.8%, 91.1%, and 91.0%, respectively. Furthermore, we have made manual annotations of the blood vessel topologies for INSPIRE, IOSTAR, VICAVR, and DRIVE datasets, and these annotations are released for public access so as to facilitate researchers in the community.

3 January 2023 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
JXJianyang Xie
Jianyang Xie
QYQuanyong Yi
Quanyong Yi
YWYufei Wu
Yufei Wu
Yalin ZhengYalin Zheng
Yalin Zheng
YLYonghuai Liu
Yonghuai Liu
Yifan ZhaoYifan Zhao
Yifan Zhao
Background Optical coherence tomography angiography (OCTA) enables fast and non-invasive high-resolution imaging of retinal microvasculature and is suggested as a potential tool in the early detection of retinal microvascular changes in Alzheimer’s Disease (AD). We developed a standardised OCTA analysis framework and compared their extracted parameters among controls and AD/mild cognitive impairment (MCI) in a cross-section study. Methods We defined and extracted geometrical parameters of retinal microvasculature at different retinal layers and in the foveal avascular zone (FAZ) from segmented OCTA images obtained using well-validated state-of-the-art deep learning models. We studied these parameters in 158 subjects (62 healthy control, 55 AD and 41 MCI) using logistic regression to determine their potential in predicting the status of our subjects. Results In the AD group, there was a significant decrease in vessel area and length densities in the inner vascular complexes (IVC) compared with controls. The number of vascular bifurcations in AD is also significantly lower than that of healthy people. The MCI group demonstrated a decrease in vascular area, length densities, vascular fractal dimension and the number of bifurcations in both the superficial vascular complexes (SVC) and the IVC compared with controls. A larger vascular tortuosity in the IVC, and a larger roundness of FAZ in the SVC, can also be observed in MCI compared with controls. Conclusion Our study demonstrates the applicability of OCTA for the diagnosis of AD and MCI, and provides a standard tool for future clinical service and research. Biomarkers from retinal OCTA images can provide useful information for clinical decision-making and diagnosis of AD and MCI.

19 November 2024 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
JXJianyang Xie
Jianyang Xie
YMYanda Meng
Yanda Meng
Yifan ZhaoYifan Zhao
Yifan Zhao
ANAnh Nguyen
Anh Nguyen
XYXiaoyun Yang
Xiaoyun Yang
Yalin ZhengYalin Zheng
Yalin Zheng
Human action recognition is an essential topic in computer vision and image processing. Graph convolutional networks (GCNs) have attracted significant attention and achieved noteworthy performance in skeleton-based human action recognition tasks. However, most of the previous graph-based works are designed to refine skeleton topology without considering the types of different joints and edges and the occurrence order of the frames. Such a limitation makes them insufficient to represent intrinsic semantic information. Differently, we proposed a dynamic semantic-based spatial-temporal graph convolution network (DS-STGCN) to address the challenge. DS-STGCN has two dynamic semantic modules for spatial and temporal contexts respectively. Specifically, the joints and edge types were encoded in the spatial module implicitly, and the occurrence order of frames was encoded in the temporal module implicitly. Extensive experiments on four datasets including NTU-RGB+D 60(120), Kinetics-400, and FineGYM show that our proposed two semantic modules can bring consistent recognition performance improvement with various backbones. Meanwhile, the proposed DS-STGCN notably surpassed state-of-the-art methods on these datasets. Notably, in the more challenging dataset, such as Kinetics-400, our model significantly outperformed other state-of-the-art GCN-based methods by a large margin. The code has been released at https://github.com/davelailai/DS-STGCN.

20 April 2024 in Medical Image Analysis
Verified
Journal Article
Open access
YMYanda Meng
Yanda Meng
YZYuchen Zhang
Yuchen Zhang
JXJianyang Xie
Jianyang Xie
JDJinming Duan
Jinming Duan
MJMartha Joddrell
Martha Joddrell
Yalin ZhengYalin Zheng
Yalin Zheng
Automated segmentation is a challenging task in medical image analysis that usually requires a large amount of manually labeled data. However, most current supervised learning based algorithms suffer from insufficient manual annotations, posing a significant difficulty for accurate and robust segmentation. In addition, most current semi-supervised methods lack explicit representations of geometric structure and semantic information, restricting segmentation accuracy. In this work, we propose a hybrid framework to learn polygon vertices, region masks, and their boundaries in a weakly/semi-supervised manner that significantly advances geometric and semantic representations. Firstly, we propose multi-granularity learning of explicit geometric structure constraints via polygon vertices (PolyV) and pixel-wise region (PixelR) segmentation masks in a semi-supervised manner. Secondly, we propose eliminating boundary ambiguity by using an explicit contrastive objective to learn a discriminative feature space of boundary contours at the pixel level with limited annotations. Thirdly, we exploit the task-specific clinical domain knowledge to differentiate the clinical function assessment end-to-end. The ground truth of clinical function assessment, on the other hand, can serve as auxiliary weak supervision for PolyV and PixelR learning. We evaluate the proposed framework on two tasks, including optic disc (OD) and cup (OC) segmentation along with vertical cup-to-disc ratio (vCDR) estimation in fundus images; left ventricle (LV) segmentation at end-diastolic and end-systolic frames along with ejection fraction (LVEF) estimation in two-dimensional echocardiography images. Experiments on nine large-scale datasets of the two tasks under different label settings demonstrate our model's superior performance on segmentation and clinical function assessment.

9 May 2018 in Medical Physics
Verified
Journal Article
Open access
PDF file
TNTong Na
Tong Na
JXJianyang Xie
Jianyang Xie
Yifan ZhaoYifan Zhao
Yifan Zhao
Yifan ZhaoYifan Zhao
Yifan Zhao
YLYue Liu
Yue Liu
JLJiang Liu
Jiang Liu
Purpose: Automatic methods of analyzing of retinal vascular networks, such as retinal blood vessel detection, vascular network topology estimation, and arteries/veins classification are of great assistance to the ophthalmologist in terms of diagnosis and treatment of a wide spectrum of diseases.Methods: We propose a new framework for precisely segmenting retinal vasculatures, constructing retinal vascular network topology, and separating the arteries and veins. A nonlocal total variation inspired Retinex model is employed to remove the image intensity inhomogeneities and relatively poor contrast. For better generalizability and segmentation performance, a superpixel‐based line operator is proposed as to distinguish between lines and the edges, thus allowing more tolerance in the position of the respective contours. The concept ofdominant sets clusteringis adopted to estimate retinal vessel topology and classify the vessel network into arteries and veins.Results: The proposed segmentation method yields competitive results on three public data sets (STARE, DRIVE, and IOSTAR), and it has superior performance when compared with unsupervised segmentation methods, with accuracy of 0.954, 0.957, and 0.964, respectively. The topology estimation approach has been applied to five public databases (DRIVE,STARE, INSPIRE, IOSTAR, and VICAVR) and achieved high accuracy of 0.830, 0.910, 0.915, 0.928, and 0.889, respectively. The accuracies of arteries/veins classification based on the estimated vascular topology on three public databases (INSPIRE, DRIVE and VICAVR) are 0.90.9, 0.910, and 0.907, respectively.Conclusions: The experimental results show that the proposed framework has effectively addressed crossover problem, a bottleneck issue in segmentation and vascular topology reconstruction. The vascular topology information significantly improves the accuracy on arteries/veins classification.