Yoann Lafon

Yoann Lafon

Auto-generated profile, based on publicly available information

Yoann Lafon

Univ. Lyon, Univ. Gustave Eiffel

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2004 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
DPD. Périé
D. Périé
CAC. E. Aubin
C. E. Aubin
MLM. Lacroix
M. Lacroix
YLY. Lafon
Y. Lafon
HLH. Labelle
H. Labelle

2 November 2009 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Conference Paper
Closed access
PBPhilippe Beillas
Philippe Beillas
YLYoann Lafon
Yoann Lafon
FSFrancis W. Smith
Francis W. Smith
In this study, the thorax and the abdomen of nine subjects were imaged in four postures using a positional MRI scanner. The four postures were seated, standing, forward-flexed and supine. They were selected to represent car occupants, pedestrians, cyclists and a typical position for medical imaging, respectively. Geometrical models of key anatomical structures were registered from the imaging dataset using a custom registration toolbox. The analysis of the images and models allowed the quantification of the respective effects of posture and subject-to-subject variation on the position, shape and volume of the abdominal organs, skeletal components and thoracic cavity. In summary, except for the supine posture, the organ volumes and their positions in the spinal frame were mostly unaffected by the posture. The supine posture was associated with a motion of all solid organs of up to 39 mm (interpostural maximum for the liver, n=9), and a reduction of the thoracic cavity volume of up to 1300 cm3. Subject-to-subject variations were especially large for the volume of the spleen (variations between 120 and 400 cm3) and the position of the kidneys. As a result, subject-to-subject variations were larger than most postural effects. Other results include values of parameters that can help positioning human models such as positions, volumes and inertial properties of organs as well as skeletal parameters. Overall, this study suggests that subject-to-subject variations and the use of supine geometrical data can be problematic for finite element modeling of the abdomen for injury prediction.

1 March 2009 in Spine
Verified
Journal Article
Closed access
YLYoann Lafon
Yoann Lafon
VLVirginie Lafage
Virginie Lafage
JDJean Dubousset
Jean Dubousset
WSWafa Skalli
Wafa Skalli
A numerical study was conducted by simulating the Cotrel-Dubousset (CD) surgery. To quantify intraoperative correction during CD surgery. Very few methods have been reported in literature to analyze the effect of intraoperative surgical gestures, and none considers the three-dimensional correction of the entire spine during the main surgical gestures. Intraoperative frontal radiographs limit analysis to two-dimensional correction, and movement tracking devices focus the kinematics study of specific vertebrae in the instrumented area only. This study included 20 patients, mean age 15 years, with severe idiopathic scoliosis treated by CD surgery. A patient-specific finite-element model (T1-L5 and pelvis), based on preoperative stereo-radiography and flexibility test radiographs, was constructed for each patient. An automated algorithm simulated all the main steps of the CD surgery. For each step, vertebral kinematics was exported to compute the evolution of various clinical parameters. Coherence of the simulations was evaluated by comparing the virtual postoperative spinal configuration with postoperative in vivo data. The CD surgery affected the vertebral levels inside but also outside the fused spinal area, in a three-dimensional complex kinematics. Every intraoperative maneuver contributes to scoliosis correction. The second rod insertion, focused on the apical vertebra, leading to a global modification of all the curves. The automated patient-specific simulation of CD surgery may improve our understanding of surgical biomechanics. Therefore, it could increase the relevance of preoperative surgery planning.

1 May 2010 in Spine
Verified
Journal Article
Closed access
XDX. Drevelle
X. Drevelle
YLY. Lafon
Y. Lafon
EEE. Ebermeyer
E. Ebermeyer
ICI. Courtois
I. Courtois
JDJ. Dubousset
J. Dubousset
WSW. Skalli
W. Skalli
Study Design. The mechanisms of idiopathic scoliosis progression were investigated through a patient-specific numerical model. Objective. To explore the combined effect of gravity, the decrease of intervertebral discs' stiffness and the anterior spinal growth on scoliosis progression, by using a numerical simulation, to better understand mechanisms of scoliosis progression. Summary of Background Data. Eighteen adolescents (12 girls, 6 boys) with an average age of 10.5 years (range, 7-13) were divided into 2 groups: 12 mild scoliotic patients with thoracolumbar curves and 6 asymptomatic subjects. Methods. Accurate 3-dimensional reconstructions of the spine were performed from biplanar radiographs. A patient-specific validated finite element model was used. Four configurations were simulated for each patient: the first configuration with the spine under gravity, the second one under gravity with a decrease of disc's mechanical stiffness, the third one under gravity with anterior vertebral growth, and the last one with combination of the 3 previous configurations. Results. Gravity loads resulted mainly in a vertebral lateral deviation of the curve without axial rotation for all patients with mild scoliosis. Anterior vertebral growth with gravity induced both lateral deviation and axial rotation. This phenomenon was amplified when the mechanical properties of discs were decreased. None of these simulations initiated a scoliosis-like deformity for asymptomatic subjects. Conclusion. For preexisting spinal curvature, an anterior spinal growth combined with gravity and a decrease of disc's mechanical stiffness could lead to a progression of scoliosis. Biomechanical factors could be secondary after initial deformation.

1 May 2010 in Journal of Biomechanics
Verified
Journal Article
Closed access
YLY. Lafon
Y. Lafon
FSF.W. Smith
F.W. Smith
PBP. Beillas
P. Beillas

1 October 2005 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
Raphael DumasRaphael Dumas
Raphael Dumas
VLVirginie Lafage
Virginie Lafage
YLY. Lafon
Y. Lafon
JSJ-P. Steib
J-P. Steib
DMD. Mitton
D. Mitton
WSW. Skalli
W. Skalli
Biomechanical models have been proposed in order to simulate the surgical correction of spinal deformities. With these models, different surgical correction techniques have been examined: distraction and rod rotation. The purpose of this study was to simulate another surgical correction technique: the in situ contouring technique. In this way, a comprehensive three-dimensional Finite Element (FE) model with patient-specific geometry and patient-specific mechanical properties was used. The simulation of the surgery took into account elasto–plastic behavior of the rod and multiple moments loading and unloading representing the surgical maneuvers. The simulations of two clinical cases of hyperkyphosis and scoliosis were coherent with the surgeon's experience. Moreover, the results of simulation were compared to post-operative 3D measurements. The mean differences were under 5° for vertebral rotations and 5 mm for spinal lines. These simulations open the way for future predictive tools for surgical planning.