Magneto-Inertial Measurement Unit sensors (MIMU) display high potential for the quantitative evaluation of upper limb kinematics, as they allow monitoring ambulatory measurements. The sensor-to-segment calibration step, consisting of establishing the relation between MIMU sensors and human segments, plays an important role in the global accuracy of joint angles. The aim of this study was to compare sensor-to-segment calibrations for the MIMU-based estimation of wrist, elbow, and shoulder joint angles, by examining trueness (“close to the reference”) and precision (reproducibility) validity criteria. Ten subjects performed five sessions with three different operators. Three classes of calibrations were studied: segment axes equal to technical MIMU axes (TECH), segment axes generated during a static pose (STATIC), and those generated during functional movements (FUNCT). The calibrations were compared during the maximal uniaxial movements of each joint, plus an extra multi-joint movement. Generally, joint angles presented good trueness and very good precision in the range 5°–10°. Only small discrepancy between calibrations was highlighted, with the exception of a few cases. The very good overall accuracy (trueness and precision) of MIMU-based joint angle data seems to be more dependent on the level of rigor of the experimental procedure (operator training) than on the choice of calibration itself.
1 April 2010 in Journal of Strength & Conditioning Research
The purpose of this study was to compare the main kinematic, kinetic, and dynamic parameters of elite and well-trained sprinters during the starting block phase and the 2 subsequent steps. Six elite sprinters (10.06-10.43 s/100 m) and 6 well-trained sprinters (11.01-11.80 s/100 m) equipped with 63 passive reflective markers performed 4 maximal 10 m sprint starts on an indoor track. An opto-electronic motion analysis system consisting of 12 digital cameras (250 Hz) was used to record 3D marker trajectories. At the times "on your marks," "set," "clearing the block," and "landing and toe-off of the first and second step," the horizontal position of the center of mass (CM), its velocity (XCM and VCM), and the horizontal position of the rear and front hand (X(Hand_rear) and X(Hand_front)) were calculated. During the pushing phase on the starting block and the 2 first steps, the rate of force development and the impulse (F(impulse)) were also calculated. The main results showed that at each time XCM and VCM were significantly greater in elite sprinters. Moreover, during the pushing phase on the block, the rate of force development and F(impulse) were significantly greater in elite sprinters (respectively, 15,505 +/- 5,397 N.s and 8,459 +/- 3,811 N.s for the rate of force development; 276.2 +/- 36.0 N.s and 215.4 +/- 28.5 N.s for F(impulse), p < or = 0.05). Finally, at the block clearing, elite sprinters showed a greater XHand_rear and X(Hand_front) than well-trained sprinters (respectively, 0.07+/- 0.12 m and -0.27 +/- 0.36 m for X(Hand_rear); 1.00 +/- 0.14 m and 0.52 +/- 0.27 m for X(Hand_front); p < or = 0.05). The muscular strength and arm coordination appear to characterize the efficiency of the sprint start. To improve speed capacities of their athletes, coaches must include in their habitual training sessions of resistance training.
1 December 2003 in Surgical and Radiologic Anatomy
A detorsion analysis of the scoliosis surgical correction by means of in situ contouring technique (ISC). To describe the technique of ISC. To measure the vertebral and intervertebral axial rotation in thoracic and lumbar curves and their correction obtained by ISC. The vertebral and intervertebral axial rotation allows to evaluate the severity of the curves. However, the intervertebral axial rotation is barely studied and the vertebral axial rotation is a controversial point of the surgical correction. Twenty patients with thoracic and lumbar scoliosis were operated on with ISC. Vertebral axial rotation at the apex and the sum of intervertebral axial rotations all along the curve were computed before and after surgery from the three-dimensional stereoradiographic reconstruction of the spine and the pelvis. All the measurements were made in the standing position. Correction of the axial rotation was obtained at the apex of both thoracic and lumbar curves of idiopathic and degenerative scoliosis. The mean values of correction (in terms of axial rotation) were 8 degrees to 19 degrees (62%-67%). The percentage of correction of the sum of intervertebral axial rotations all along the curve, proposed as a "detorsion index" (preoperative - postoperative/preoperative), was found at 57% to 92%. No significant differences were found for the correction (in terms of axial rotation and detorsion) between idiopathic and degenerative curves. The axial rotation was measured in clinics on standing patients with scoliosis from three-dimensional stereoradiographic reconstruction and demonstrated a reliable detorsion obtained by ISC.