1 September 2017 in Journal of Neuro-Ophthalmology
The purpose of this study was to evaluate the pupil response to chromatic stimuli in patients with lesions in the dorsal midbrain and possibly gain new insights into the afferent pupillary pathways. Color pupillography was performed in 5 patients with dorsal midbrain syndrome (DMS), and their results were compared with those of 20 healthy control subjects. We used full-field red stimuli (605 nm) that primarily address the rod/cone system and blue stimuli (420 nm) that preferentially activate intrinsically photosensitive retinal ganglion cells (ipRGCs) directly, with a duration of 4 seconds and a stimulus intensity of 28 lx corneal illumination under mesopic conditions. One eye was stimulated, and the consensual pupil response was recorded and analyzed. The pupillary light reflex in patients with DMS was reduced, differed in shape, and showed a prolonged latency time compared to normal subjects. The blue response was less affected than the red response: the mean maximal relative amplitude (M) was 15.8% (SD = 7.8) in patients with DMS compared with 43.0% (SD = 5.5) in normal subjects for red stimulation, and M = 40.8%, SD = 8.4 (DMS) with M = 58.3%, SD = 4.8 (normals) for blue stimulation. The reduction was 63% for red stimulation but only 30% for blue stimulation in patients with DMS. Moreover, there was a preserved postillumination pupil response to blue stimulation in DMS patients. In DMS, the melanopsin-mediated ipRGC pathway appeared relatively preserved.
1 November 2023 in Clinical Ophthalmology
Purpose: There are many unclear points about the accuracy of measurement of cycloplegic refraction using the Spot Vision Screener (SVS). This study aimed to investigate the accuracy of SVS measurements with cycloplegia for myopia. Materials and Methods: Forty-nine healthy subjects were included, and refraction was measured. Objective refractions were measured by SVS, table-mounted autorefractometer (RT7000), and handheld autorefractometer (Retinomax Screeen) at noncycloplegic and cycloplegic conditions by 1% cyclopentolate. Subjective noncycloplegic refraction was obtained by a visual acuity and refraction test performed by certified orthoptists using a cross-cylinder. One-way repeated-measures analysis of variance was used to examine whether the measured refractions fluctuate due to different reflection tests. Results: In the noncycloplegic condition, the mean (±standard deviation) spherical equivalent (SE) measured by subjective method, SVS, RT7000, and Retinomax Screeen were − 2.56 ± 3.00, − 2.62 ± 2.38, − 3.05 ± 2.84, and − 3.26 ± 2.97, respectively. The subjective SE and objective SE measured by SVS had significantly less myopic value than the objective SE measured by two autorefractometers (p < 0.001). In the cycloplegic condition, the mean (± standard deviation) SE measured by SVS, RT7000, and Retinomax Screeen were − 2.07 ± 2.66, − 2.62 ± 2.98, and − 2.66 ± 3.02, respectively. The objective SE measured by SVS had significantly less myopic value than SEs measured using other methods (p < 0.001). In the cycloplegic condition, SVS showed a fixed error wherein the SE was more hyperopic than that with the subjective method and SVS had a proportional error. Conclusion: In the measurement under cycloplegic conditions, use of an autorefractometer rather than a photorefractometer such as SVS was preferable.
1 October 2020 in Clinical Ophthalmology
Purpose: We investigated whether or not intrasession or intersession fluctuations in intraocular pressure occur in healthy people using a noncontact tonometer. Materials and Methods: A noncontact tonometer was used to measure intraocular pressure in the bilateral eyes of healthy subjects for 5 consecutive days. Paired t-tests and one- and two-way repeated-measures analyses of variance were performed for the acquired data. A p-value < 0.05 was considered to indicate statistical significance. Results: Eighty eyes of 40 healthy subjects were enrolled in the study. On day 1, intraocular pressure was significantly higher in the right eye than in the left eye (P = 0.014). The one-way repeated-measures analysis of variance revealed that intraocular pressure in the left eye was significantly lower on day 1 than on days 2 to 5 (P = 0.000– 0.018); however, there were no significant differences among intraocular pressures measured on days 1 to 5 in the right eye. The two-way repeated-measures analysis of variance revealed no significant difference in intraocular pressure between the right and left eyes (P = 0.913). Conclusion: Although measurements using the noncontact tonometer were relatively stable, intraocular pressure was high on day 1.
1 November 2021 in Clinical Ophthalmology
Purpose: Intraocular pressure (IOP) measured using a noncontact tonometer is evaluated by performing multiple measurements because IOP is affected by the ocular pulse. We investigated the relationship between value fluctuations in multiple measurements during noncontact tonometer measurements and cardiac rate. Materials and Methods: Forty-two healthy subjects were included and IOP was measured using a noncontact tonometer. The measurement was performed three times each for the right eye and the left eye, for a total of six times. Blood pressure and cardiac rate were measured at the same time as the IOP measurement. Using repeated-measures analysis of variance, we examined whether the measured IOP and cardiac rate fluctuate throughout the day over the course of 4 days. Results: There was a fluctuation in the IOP in a sequence only on day 1 of the four measurement days (P < 0.001). The IOP on day 1 tended to be high for the first and second measurements (P = 0.0111– 0.0015). Systolic blood pressure and diastolic blood pressure did not fluctuate over the 4 days (P = 0.6247 and 0.7132), but cardiac rate was high only on day 1 (P = 0.0276). Conclusion: The IOP on day 1 tended to be high in the first and second measurements. The IOP measured on days 2– 4 did not fluctuate during the sequence of measurements. The cardiac rate measured at the same time as the IOP was high only on the first day.
21 July 2022 in Optical Review