3 July 2020 in JMIR Human Factors
Background: The patient monitor (PM) is one of the most commonly used medical devices in hospitals worldwide. PMs are used to monitor patients’ vital signs in a wide variety of patient care settings, especially in critical care settings, such as intensive care units. An interesting observation is that the design of PMs has not significantly changed over the past 2 decades, with the layout and structure of PMs more or less unchanged, with incremental changes in design being made rather than transformational changes. Thus, we believe it well-timed to review the design of novel PM interfaces, with particular reference to usability and human factors. Objective: This paper aims to review innovations in PM design proposed by researchers and explore how clinicians responded to these design changes. Methods: A literature search of relevant databases, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, identified 16 related studies. A detailed description of the interface design and an analysis of each novel PM were carried out, including a detailed analysis of the structure of the different user interfaces, to inform future PM design. The test methodologies used to evaluate the different designs are also presented. Results: Most of the studies included in this review identified some level of improvement in the clinician’s performance when using a novel display in comparison with the traditional PM. For instance, from the 16 reviewed studies, 12 studies identified an improvement in the detection and response times, and 10 studies identified an improvement in the accuracy or treatment efficiency. This indicates that novel displays have the potential to improve the clinical performance of nurses and doctors. However, the outcomes of some of these studies are weakened because of methodological deficiencies. These deficiencies are discussed in detail in this study. Conclusions: More careful study design is warranted to investigate the user experience and usability of future novel PMs for real time vital sign monitoring, to establish whether or not they could be used successfully in critical care. A series of recommendations on how future novel PM designs and evaluations can be enhanced are provided.
25 May 2021 in JMIR Human Factors
Background: Continuous monitoring of the vital signs of critical care patients is an essential component of critical care medicine. For this task, clinicians use a patient monitor (PM), which conveys patient vital sign data through a screen and an auditory alarm system. Some limitations with PMs have been identified in the literature, such as the need for visual contact with the PM screen, which could result in reduced focus on the patient in specific scenarios, and the amount of noise generated by the PM alarm system. With the advancement of material science and electronic technology, wearable devices have emerged as a potential solution for these problems. This review presents the findings of several studies that focused on the usability and human factors of wearable devices designed for use in critical care patient monitoring. Objective: The aim of this study is to review the current state of the art in wearable devices intended for use by clinicians to monitor vital signs of critical care patients in hospital settings, with a focus on the usability and human factors of the devices. Methods: A comprehensive literature search of relevant databases was conducted, and 20 studies were identified and critically reviewed by the authors. Results: We identified 3 types of wearable devices: tactile, head-mounted, and smartwatch displays. In most cases, these devices were intended for use by anesthesiologists, but nurses and surgeons were also identified as potentially important users of wearable technology in critical care medicine. Although the studies investigating tactile displays revealed their potential to improve clinical monitoring, usability problems related to comfort need to be overcome before they can be considered suitable for use in clinical practice. Only a few studies investigated the usability and human factors of tactile displays by conducting user testing involving critical care professionals. The studies of head-mounted displays (HMDs) revealed that these devices could be useful in critical care medicine, particularly from an ergonomics point of view. By reducing the amount of time the user spends averting their gaze from the patient to a separate screen, HMDs enable clinicians to improve their patient focus and reduce the potential of repetitive strain injury. Conclusions: Researchers and designers of new wearable devices for use in critical care medicine should strive to achieve not only enhanced performance but also enhanced user experience for their users, especially in terms of comfort and ease of use. These aspects of wearable displays must be extensively tested with the intended end users in a setting that properly reflects the intended context of use before their adoption can be considered in clinical settings.
1 January 2025 in Advances in Public Health
Background: The manufacturing sector drives global industrial growth and economic prosperity, yet concerns persist about ergonomic hazards causing widespread work‐related musculoskeletal disorders (WMSDs). This study aims to examine how physical and psychological strains contribute to the risk of WMSDs among manufacturing workers in Indonesia. Method: From September 2023 to March 2024, a cross‐sectional quantitative study surveyed 1714 manufacturing workers. Structured questionnaires covered demographics, work factors, psychosocial conditions, and musculoskeletal symptoms. Statistical analyses included univariate, bivariate, and multivariate methods. Result: About one‐third of respondents reported high‐risk WMSD symptoms over short and long terms, primarily affecting critical body regions. Males faced greater risks, while younger workers showed some protection. Physical activity levels, job factors, and psychosocial conditions significantly influenced WMSD risk. Role clarity was protective, while physical and psychological stressors increased MSD risk. Conclusion: This study highlights how physical and psychological strains jointly heighten WMSD risks in manufacturing. Targeted interventions addressing both ergonomic and psychological factors are crucial to improve workplace health and safety for manufacturing workers.
4 October 2019 in JMIR Preprints
BACKGROUND Continuous monitoring of the vital signs of critical care patients is an essential component of critical care medicine. For this task, clinicians use a patient monitor (PM), which conveys patient vital sign data through a screen and an auditory alarm system. Some limitations with PMs have been identified in the literature, such as the need for visual contact with the PM screen, which could result in reduced focus on the patient in specific scenarios, and the amount of noise generated by the PM alarm system. With the advancement of material science and electronic technology, wearable devices have emerged as a potential solution for these problems. This review presents the findings of several studies that focused on the usability and human factors of wearable devices designed for use in critical care patient monitoring. OBJECTIVE The aim of this study is to review the current state of the art in wearable devices intended for use by clinicians to monitor vital signs of critical care patients in hospital settings, with a focus on the usability and human factors of the devices. METHODS A comprehensive literature search of relevant databases was conducted, and 20 studies were identified and critically reviewed by the authors. RESULTS We identified 3 types of wearable devices: tactile, head-mounted, and smartwatch displays. In most cases, these devices were intended for use by anesthesiologists, but nurses and surgeons were also identified as potentially important users of wearable technology in critical care medicine. Although the studies investigating tactile displays revealed their potential to improve clinical monitoring, usability problems related to comfort need to be overcome before they can be considered suitable for use in clinical practice. Only a few studies investigated the usability and human factors of tactile displays by conducting user testing involving critical care professionals. The studies of head-mounted displays (HMDs) revealed that these devices could be useful in critical care medicine, particularly from an ergonomics point of view. By reducing the amount of time the user spends averting their gaze from the patient to a separate screen, HMDs enable clinicians to improve their patient focus and reduce the potential of repetitive strain injury. CONCLUSIONS Researchers and designers of new wearable devices for use in critical care medicine should strive to achieve not only enhanced performance but also enhanced user experience for their users, especially in terms of comfort and ease of use. These aspects of wearable displays must be extensively tested with the intended end users in a setting that properly reflects the intended context of use before their adoption can be considered in clinical settings.