Richard Harte

Richard Harte

Auto-generated profile, based on publicly available information

Richard Harte

Electrical & Electronic Engineering, School of Engineering, National University of Ireland, Galway, Galway, Ireland

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2017 in JMIR Human Factors
Verified
Journal Article
Open access
RHRichard Harte
Richard Harte
LGLiam Glynn
Liam Glynn
ARAlejandr Rodríguez-Molinero
Alejandr Rodríguez-Molinero
PBPaul Baker
Paul Baker
TSThomas Scharf
Thomas Scharf
Gearóid ÓLaighinGearóid ÓLaighin
Gearóid ÓLaighin
JMIR Human Factors - a leading peer-reviewed ehealth journal

30 May 2017 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
RHRichard Harte
Richard Harte
LQLeo Quinlan
Leo Quinlan
LGLiam Glynn
Liam Glynn
ARAlejandr Rodríguez-Molinero
Alejandr Rodríguez-Molinero
PBPaul Baker
Paul Baker
Gearóid ÓLaighinGearóid ÓLaighin
Gearóid ÓLaighin
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.

26 April 2018 in JMIR Human Factors
Verified
Journal Article
Open access
RHRichard Harte
Richard Harte
THTony Hall
Tony Hall
LGLiam Glynn
Liam Glynn
ARAlejandr Rodríguez-Molinero
Alejandr Rodríguez-Molinero
TSThomas Scharf
Thomas Scharf
Gearóid ÓLaighinGearóid ÓLaighin
Gearóid ÓLaighin
JMIR Human Factors - a leading peer-reviewed ehealth journal

3 July 2020 in JMIR Human Factors
Verified
Journal Article
Open access
EAEvismar Andrade
Evismar Andrade
LQLeo Quinlan
Leo Quinlan
RHRichard Harte
Richard Harte
DBDara Byrne
Dara Byrne
EFEnda Fallon
Enda Fallon
Gearóid ÓLaighinGearóid ÓLaighin
Gearóid ÓLaighin
Background: The patient monitor (PM) is one of the most commonly used medical devices in hospitals worldwide. PMs are used to monitor patients’ vital signs in a wide variety of patient care settings, especially in critical care settings, such as intensive care units. An interesting observation is that the design of PMs has not significantly changed over the past 2 decades, with the layout and structure of PMs more or less unchanged, with incremental changes in design being made rather than transformational changes. Thus, we believe it well-timed to review the design of novel PM interfaces, with particular reference to usability and human factors. Objective: This paper aims to review innovations in PM design proposed by researchers and explore how clinicians responded to these design changes. Methods: A literature search of relevant databases, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, identified 16 related studies. A detailed description of the interface design and an analysis of each novel PM were carried out, including a detailed analysis of the structure of the different user interfaces, to inform future PM design. The test methodologies used to evaluate the different designs are also presented. Results: Most of the studies included in this review identified some level of improvement in the clinician’s performance when using a novel display in comparison with the traditional PM. For instance, from the 16 reviewed studies, 12 studies identified an improvement in the detection and response times, and 10 studies identified an improvement in the accuracy or treatment efficiency. This indicates that novel displays have the potential to improve the clinical performance of nurses and doctors. However, the outcomes of some of these studies are weakened because of methodological deficiencies. These deficiencies are discussed in detail in this study. Conclusions: More careful study design is warranted to investigate the user experience and usability of future novel PMs for real time vital sign monitoring, to establish whether or not they could be used successfully in critical care. A series of recommendations on how future novel PM designs and evaluations can be enhanced are provided.

16 December 2015 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
RHRichard Harte
Richard Harte
LQLeo Quinlan
Leo Quinlan
LGLiam Glynn
Liam Glynn
ARAlejandro Rodriguez-Molinero
Alejandro Rodriguez-Molinero
TSThomas Scharf
Thomas Scharf
Gearóid ÓLaighinGearóid ÓLaighin
Gearóid ÓLaighin
Wearable electronics are gaining widespread use as enabling technologies, monitoring human physical activity and behavior as part of connected health infrastructures. Attention to human factors and comfort of these devices can greatly positively influence user experience, with a subsequently higher likelihood of user acceptance and lower levels of device rejection. Here, we employ a human factors and comfort assessment methodology grounded in the principles of human-centered design to influence and enhance the design of an instrumented insole. A use case was developed and interrogated by stakeholders, experts, and end users, capturing the context of use and user characteristics for the instrumented insole. This use case informed all stages of the design process through two full design cycles, leading to the development of an initial version 1 and a later version 2 prototype. Each version of the prototype was subjected to an expert human factors inspection and controlled comfort assessment using human volunteers. Structured feedback from the first cycle of testing was the driver of design changes implemented in the version 2 prototype. This prototype was found to have significantly improved human factors and comfort characteristics over the first version of the prototype. Expert inspection found that many of the original problems in the first prototype had been resolved in the second prototype. Furthermore, a comfort assessment of this prototype with a group of young healthy adults showed it to be indistinguishable from their normal footwear. This study demonstrates the power and effectiveness of human factors and comfort assessment methodologies in influencing and improving the design of wearable devices.

25 May 2021 in JMIR Human Factors
Verified
Journal Article
Open access
EAEvismar Andrade
Evismar Andrade
LQLeo Quinlan
Leo Quinlan
RHRichard Harte
Richard Harte
DBDara Byrne
Dara Byrne
EFEnda Fallon
Enda Fallon
Gearóid ÓLaighinGearóid ÓLaighin
Gearóid ÓLaighin
Background: Continuous monitoring of the vital signs of critical care patients is an essential component of critical care medicine. For this task, clinicians use a patient monitor (PM), which conveys patient vital sign data through a screen and an auditory alarm system. Some limitations with PMs have been identified in the literature, such as the need for visual contact with the PM screen, which could result in reduced focus on the patient in specific scenarios, and the amount of noise generated by the PM alarm system. With the advancement of material science and electronic technology, wearable devices have emerged as a potential solution for these problems. This review presents the findings of several studies that focused on the usability and human factors of wearable devices designed for use in critical care patient monitoring. Objective: The aim of this study is to review the current state of the art in wearable devices intended for use by clinicians to monitor vital signs of critical care patients in hospital settings, with a focus on the usability and human factors of the devices. Methods: A comprehensive literature search of relevant databases was conducted, and 20 studies were identified and critically reviewed by the authors. Results: We identified 3 types of wearable devices: tactile, head-mounted, and smartwatch displays. In most cases, these devices were intended for use by anesthesiologists, but nurses and surgeons were also identified as potentially important users of wearable technology in critical care medicine. Although the studies investigating tactile displays revealed their potential to improve clinical monitoring, usability problems related to comfort need to be overcome before they can be considered suitable for use in clinical practice. Only a few studies investigated the usability and human factors of tactile displays by conducting user testing involving critical care professionals. The studies of head-mounted displays (HMDs) revealed that these devices could be useful in critical care medicine, particularly from an ergonomics point of view. By reducing the amount of time the user spends averting their gaze from the patient to a separate screen, HMDs enable clinicians to improve their patient focus and reduce the potential of repetitive strain injury. Conclusions: Researchers and designers of new wearable devices for use in critical care medicine should strive to achieve not only enhanced performance but also enhanced user experience for their users, especially in terms of comfort and ease of use. These aspects of wearable displays must be extensively tested with the intended end users in a setting that properly reflects the intended context of use before their adoption can be considered in clinical settings.