Mathijs Bronkhorst

Mathijs Bronkhorst

Auto-generated profile, based on publicly available information

Mathijs Bronkhorst

Artinis Medical Systems BV, Einsteinweg 17, 6662 PW Elst, The Netherlands

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2019 in PLOS Biology
Verified
Journal Article
Open access
PDF file
JMJ. Chris McKnight
J. Chris McKnight
KBKimberley A. Bennett
Kimberley A. Bennett
MBMathijs Bronkhorst
Mathijs Bronkhorst
DRDeborah Russell
Deborah Russell
SBSteve Balfour
Steve Balfour
DTDave Thompson
Dave Thompson
Investigation of marine mammal dive-by-dive blood distribution and oxygenation has been limited by a lack of noninvasive technology for use in freely diving animals. Here, we developed a noninvasive near-infrared spectroscopy (NIRS) device to measure relative changes in blood volume and haemoglobin oxygenation continuously in the blubber and brain of voluntarily diving harbour seals. Our results show that seals routinely exhibit preparatory peripheral vasoconstriction accompanied by increased cerebral blood volume approximately 15 s before submersion. These anticipatory adjustments confirm that blood redistribution in seals is under some degree of cognitive control that precedes the mammalian dive response. Seals also routinely increase cerebral oxygenation at a consistent time during each dive, despite a lack of access to ambient air. We suggest that this frequent and reproducible reoxygenation pattern, without access to ambient air, is underpinned by previously unrecognised changes in cerebral drainage. The ability to track blood volume and oxygenation in different tissues using NIRS will facilitate a more accurate understanding of physiological plasticity in diving animals in an increasingly disturbed and exploited environment.

28 June 2021 in Philosophical Transactions of the Royal Society B: Biological Sciences
Verified
Journal Article
Open access
JMJ. Chris McKnight
J. Chris McKnight
EMEric Mulder
Eric Mulder
ARAlexander Ruesch
Alexander Ruesch
JKJana M. Kainerstorfer
Jana M. Kainerstorfer
JWJingyi Wu
Jingyi Wu
ESErika Schagatay
Erika Schagatay
Continuous measurements of haemodynamic and oxygenation changes in free living animals remain elusive. However, developments in biomedical technologies may help to fill this knowledge gap. One such technology is continuous-wave near-infrared spectroscopy (CW-NIRS)—a wearable and non-invasive optical technology. Here, we develop a marinized CW-NIRS system and deploy it on elite competition freedivers to test its capacity to function during deep freediving to 107 m depth. We use the oxyhaemoglobin and deoxyhaemoglobin concentration changes measured with CW-NIRS to monitor cerebral haemodynamic changes and oxygenation, arterial saturation and heart rate. Furthermore, using concentration changes in oxyhaemoglobin engendered by cardiac pulsation, we demonstrate the ability to conduct additional feature exploration of cardiac-dependent haemodynamic changes. Freedivers showed cerebral haemodynamic changes characteristic of apnoeic diving, while some divers also showed considerable elevations in venous blood volumes close to the end of diving. Some freedivers also showed pronounced arterial deoxygenation, the most extreme of which resulted in an arterial saturation of 25%. Freedivers also displayed heart rate changes that were comparable to diving mammals both in magnitude and patterns of change. Finally, changes in cardiac waveform associated with heart rates less than 40 bpm were associated with changes indicative of a reduction in vascular compliance. The success here of CW-NIRS to non-invasively measure a suite of physiological phenomenon in a deep-diving mammal highlights its efficacy as a future physiological monitoring tool for human freedivers as well as free living animals. This article is part of the theme issue ‘Measuring physiology in free-living animals (Part II)’.

14 June 2021 in Philosophical Transactions of the Royal Society B: Biological Sciences
Verified
Journal Article
Open access
JMJ. Chris McKnight
J. Chris McKnight
ARAlexander Ruesch
Alexander Ruesch
KBKimberley Bennett
Kimberley Bennett
MBMathijs Bronkhorst
Mathijs Bronkhorst
SBSteve Balfour
Steve Balfour
GHGordon D. Hastie
Gordon D. Hastie
Sensory ecology and physiology of free-ranging animals is challenging to study but underpins our understanding of decision-making in the wild. Existing non-invasive human biomedical technology offers tools that could be harnessed to address these challenges. Functional near-infrared spectroscopy (fNIRS), a wearable, non-invasive biomedical imaging technique measures oxy- and deoxyhaemoglobin concentration changes that can be used to detect localized neural activation in the brain. We tested the efficacy of fNIRS to detect cortical activation in grey seals (Halichoerus grypus) and identify regions of the cortex associated with different senses (vision, hearing and touch). The activation of specific cerebral areas in seals was detected by fNIRS in responses to light (vision), sound (hearing) and whisker stimulation (touch). Physiological parameters, including heart and breathing rate, were also extracted from the fNIRS signal, which allowed neural and physiological responses to be monitored simultaneously. This is, to our knowledge, the first time fNIRS has been used to detect cortical activation in a non-domesticated or laboratory animal. Because fNIRS is non-invasive and wearable, this study demonstrates its potential as a tool to quantitatively investigate sensory perception and brain function while simultaneously recording heart rate, tissue and arterial oxygen saturation of haemoglobin, perfusion changes and breathing rate in free-ranging animals. This article is part of the theme issue ‘Measuring physiology in free-living animals (Part I)’.

13 July 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
NHNaser Hakimi
Naser Hakimi
JHJörn Martin Horschig
Jörn Martin Horschig
TAThomas Alderliesten
Thomas Alderliesten
MBMathijs Bronkhorst
Mathijs Bronkhorst
MFMarianne J. Floor-Westerdijk
Marianne J. Floor-Westerdijk
Jeroen DudinkJeroen Dudink
Jeroen Dudink
Near-infrared spectroscopy (NIRS) intensity signals provide useful additional physiological information of which the most prominent one is the pulsatile fluctuation by heartbeats. This allows for the extraction of heart rate (HR), one of the primary clinical indicators of health in neonates. In this study, we propose a novel algorithm, NHR (NIRS HR), for extracting HR from NIRS signals acquired from neonates admitted to the neonatal intensive care unit. After parental consent, we recorded synchronously NIRS, at 100 Hz, and reference HR, at 1 Hz, from ten newborn infants (gestational age = 38 ± 5 weeks; 3092 ± 990 grams). The NHR algorithm consists of two main parts. The first part includes four steps implemented once on the whole NIRS measurement: preprocessing, HR frequency bandwidth determination, interquartile range computation, and segmentation. The second part includes three steps implemented on each signal segment: motion artifact detection, signal quality assessment, and HR computation. We compared the NHR algorithm with two existing algorithms. The results showed that the proposed NHR algorithm provides a significantly (p<0.05) higher correlation (r=99.5%) and lower Bland-Altman ratio (BAR=3.6%) between the extracted and reference HRs, compared to the existing algorithms. Extracting HR from NIRS in a clinical setting of critically ill neonates admitted to neonatal intensive care is feasible. With NIRS and HR combined in a single monitoring system, it is possible to have a perfectly time-synced integrated analysis of cerebral hemodynamics as well as systemic hemodynamics and autonomic nervous system tone.