Julian Arango Toro

Julian Arango Toro

Auto-generated profile, based on publicly available information

Julian Arango Toro

Universidad de Medellín, Telecommunications Engineering, Medellín, Colombia

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2021 in Textile Research Journal
Verified
Journal Article
Closed access
PDF file
JTJulian Arango Toro
Julian Arango Toro
WGWiller Ferney Montes Granada
Willer Ferney Montes Granada
SZSara Maria Yepes Zuluaga
Sara Maria Yepes Zuluaga
This paper describes the design and simulation of a rectangular wearable patch antenna. A parametric study of the antenna was conducted to determine the effect of subjecting it to longitudinal mechanical strain (along the x-axis) on its resonant frequency. The antenna-sensor was based on a cotton fabric dielectric and conductors made of flexible copper sheets that operated at a central frequency of 2.4 GHz, which is in one of the Industrial, Scientific, and Medical application bands. The Deming’s cycle, or Plan, Do, Check, and Act, was the adopted methodology in this study to address this research problem. The resonant cavity technique was implemented to find the relative permittivity and loss tangent of the textile substrate, and a universal testing machine was used to establish its mechanical properties (i.e., Young’s modulus and Poisson’s ratio). The mechanical properties of the dielectric materials, the elastic modulus in tensile loading (69.34 MPa), and the experimental value of the Poisson's ratio (0.342) were extracted from the literature. Based on the CST (Computer Simulation Technology) datasheet of flexible copper, its elastic modulus in tensile loading is 240 MPa and its Poisson's ratio is 0.39. A Computer Numerical Control machine was employed to cut the flexible copper, and the cotton fabric was cut by hand based on the dimensions of the ground plane. The patch was sewn with strong textile thread at the center of the ground plane and the cotton fabric. Such sewing ensured the physical resistance of the antenna to withstand the conditions of the multiple strains it was subjected to. The antenna implemented here resonated at a frequency of 2.3968 GHz (with a 0.13% error rate) and was well coupled with the transmission line with a Standing Wave Ratio of 1.04. CST Microwave Studio® software was used to simulate the antenna frequency response to mechanical strains based on the reaction of its return losses (S11 in dB) to be compared with experimental rigs that bend at a different level of stresses. In line with the theory in the literature, the resonant frequency of the antenna was linearly and inversely proportional to the applied stress, which enabled us to calculate the transduction ratio of the sensor in terms of strain versus frequency. In the experimental setup, the range of variation of the resonant frequency of the sensor was 143.6 MHz, with a very good sensitivity of 2.38 MHzμφ . These results pave the way for future studies in which this sensor is used as part of a biomedical system to monitor the vital signs of patients (such as respiratory rate, lung capacity, and performance under different types of physical effort; for example, in high-performance athletes) and diagnose diseases or other kinds of disorders associated with respiratory problems.

1 January 2024 in Journal of Engineered Fibers and Fabrics
Verified
Journal Article
Open access
JTJulian Arango Toro
Julian Arango Toro
SYSara María Yepes
Sara María Yepes
WGWiller Ferney Montes Granada
Willer Ferney Montes Granada
A patient’s respiratory rate can be measured based on the thoracic excursion during inhalation and exhalation. For this it was implemented a wearable antenna–sensor made of cotton/polyester (polycot) fabric and flexible copper was designed in electromagnetic field simulation software CST Studio Suite to operate at an industrial, scientific, and medical frequency band (ISM) of 2.4 GHz. The measurement protocol used involved conducting a thoracic anamnesis in order to manually measure the expansion of the thoracic cage during the patient’s inhalation and exhalation, as a way to validate the measurements. A wearable patch antenna was used as the thoracic deformation sensor, which allowed for anatomical adjustment to the curvature of the patients’ chests. According to the findings, the variation in the resonant frequency of the antenna–sensor was linear and decreasing in the range of 2.15–2.6 GHz (bandwidth of 450 MHz), allowing for the detection of linear changes in thoracic excursion, with a sensitivity inversely proportional to the applied effort of −2.56 MHz/µ[ ]. These results were obtained by placing the sensor in the lateral region of the thorax for patients with obesity and respiratory pathologies. The satisfactory results demonstrate a novel instrumental technique for measuring thoracic deformation using a wearable patch antenna as a physiological sensor. This is the initial step toward the automation of the proposed measurement protocol in smart digital devices for respiratory rate monitoring in biomedical applications.

1 February 2026 in Digital Health
Verified
Journal Article
Open access
JTJulian Arango Toro
Julian Arango Toro
DTDiana Tobón
Diana Tobón
Mauricio González-PalacioMauricio González-Palacio
Mauricio González-Palacio
Obstructive Sleep Apnea (OSA) is a prevalent respiratory disorder affecting millions worldwide, yet it remains underdiagnosed due to limitations in conventional diagnostic methods such as polysomnography. Recent advances in wearable technology and the integration of Internet of Things (IoT)-based systems have expanded options for OSA detection, offering real-time monitoring and improved accessibility. This paper presents a comprehensive survey of state-of-the-art diagnostic techniques, highlighting emerging wearable solutions, IoT-enabled data transmission, and machine learning algorithms for classification. While portable biomedical devices like HSAT and Morphea enhance patient comfort, challenges such as sensor displacement and measurement sensitivity persist. Furthermore, cloud-based analysis and smart patch antennas demonstrate feasibility in early studies but require rigorous validation and optimization to ensure accuracy and reliability. By synthesizing current advances, this study underscores the need for further research on sensor precision, algorithmic enhancements, and data integration to foster innovation toward effective and accessible OSA diagnostics.

8 August 2025 in ELEMENTOS
Verified
Journal Article
Open access
KCKatherine Alexandra Montero Cardona
Katherine Alexandra Montero Cardona
JGJohann Rene Delgado Gamboa
Johann Rene Delgado Gamboa
JTJulián Arango Toro
Julián Arango Toro
En la actualidad se gastan millones de dólares anuales en reconstrucciones del LCA (ligamento cruzado anterior) (cálculo hecho sobre 50.000 reconstrucciones a 17.000 dólares cada una). El fútbol, el béisbol, el baloncesto y el esquiar originan el 78% de las lesiones del LCA en deportistas. Cada año ocurren en Estados Unidos por lo menos 100.000 casos de lesiones del ligamento cruzado anterior (LCA) en deportistas jóvenes (típicamente entre los 15-25 años, pero con mayor riesgo entre los 10 y 19), las cuales originan problemas importantes tanto físicos como psicológicos y económicos. Actualmente, se han venido implementado diversas técnicas, métodos o metodologías para censar de manera mínimamente invasiva en el ligamento cruzado anterior en donde se han implementado sistemas basados en redes de sensores inalámbricas para la detección de rotación y movimiento en tres ejes enfocado a la evaluación objetiva de una terapia de rehabilitación física de rodilla. Estos sensores no han sido validados experimentalmente, por ende, no se puede analizar su respuesta experimental. Para alcanzar el objetivo de esta investigación, se usa el método PHVA (planear, hacer, verificar y actuar) que inicia con la selección y caracterización electromagnética y mecánica del textil. Luego se hace la simulación en software CST Suite para luego fabricar la antena empleando corte manual y adhesión por temperatura. Luego se empleó el analizador de redes vectorial para medir la respuesta de la antena en el espacio libre cuya respuesta fue de 2.55 GHz. Finalmente, se procederá a realizar mediciones en deportistas para evaluar la usabilidad del sensor.

7 November 2025 in Ingenierías USBMed
Verified
Journal Article
Open access
JTJulian Arango Toro
Julian Arango Toro
Mauricio González-PalacioMauricio González-Palacio
Mauricio González-Palacio
DVDiana Tobón Vallejo
Diana Tobón Vallejo
La apnea obstructiva del sueño [...] es un trastorno respiratorio grave que afecta a aproximadamente mil millones de personas entre 30 y 69 años en todo el mundo. [...] Tradicionalmente, la polisomnografía (PSG) ha sido el estándar de oro para diagnosticar la OSA, puesto que mide variables fisiológicas como la actividad cerebral, los movimientos oculares, la actividad muscular, el ritmo cardíaco y la respiración. Sin embargo, la PSG tiene limitaciones en términos de capacidad de captura de datos, clasificación de eventos respiratorios y requiere de un entorno controlado para su ejecución. Este estudio se propone desarrollar un nuevo sistema de medición y diagnóstico para OSA utilizando un sensor de deformación torácica. Dicho sistema está basado en una antena parche vestible e integra un analizador de redes vectoriales para la adquisición de datos durante el sueño. El sistema registrará la deformación de la caja torácica durante la inhalación y exhalación, apoyado en estrategias de detección de patrones para clasificar índices de apnea. La precisión y confiabilidad del sistema se validarán comparando sus resultados con los obtenidos mediante PSG. [...] Dicho enfoque innovador podría revolucionar el diagnóstico de la OSA [...].