Mark A. A. Neil

Mark A. A. Neil

Auto-generated profile, based on publicly available information

Mark A. A. Neil

Imperial College London

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 1997 in Optics Letters
Verified
Journal Article
Closed access
PDF file
MNM. A. A. Neil
M. A. A. Neil
RJR. Juškaitis
R. Juškaitis
TWT. Wilson
T. Wilson
We describe a simple method of obtaining optical sectioning in a conventional wide-field microscope by projecting a single-spatial-frequency grid pattern onto the object. Images taken at three spatial positions of the grid are processed in real time to produce optically sectioned images that are substantially similar to those obtained with confocal microscopes.

15 December 2006 in The Journal of Immunology
Verified
Journal Article
Open access
PDF file
BOBjörN ÖnFelt
BjörN ÖnFelt
SNShlomo Nedvetzki
Shlomo Nedvetzki
RBRichard K. P. Benninger
Richard K. P. Benninger
MPMarco A Purbhoo
Marco A Purbhoo
SSStefanie Sowinski
Stefanie Sowinski
DDDaniel M. Davis
Daniel M. Davis
We report that two classes of membrane nanotubes between human monocyte-derived macrophages can be distinguished by their cytoskeletal structure and their functional properties. Thin membrane nanotubes contained only F-actin, whereas thicker nanotubes, i.e., those > ∼0.7 μm in diameter, contained both F-actin and microtubules. Bacteria could be trapped and surf along thin, but not thick, membrane nanotubes toward connected macrophage cell bodies. Once at the cell body, bacteria could then be phagocytosed. The movement of bacteria is aided by a constitutive flow of the nanotube surface because streptavidin-coated beads were similarly able to traffic along nanotubes between surface-biotinylated macrophages. Mitochondria and intracellular vesicles, including late endosomes and lysosomes, could be detected within thick, but not thin, membrane nanotubes. Analysis from kymographs demonstrated that vesicles moved in a stepwise, bidirectional manner at ∼1 μm/s, consistent with their traffic being mediated by the microtubules found only in thick nanotubes. Vesicular traffic in thick nanotubes and surfing of beads along thin nanotubes were both stopped upon the addition of azide, demonstrating that both processes require ATP. However, microtubule destabilizing agents colchicine or nocodazole abrogated vesicular transport but not the flow of the nanotube surface, confirming that distinct cytoskeletal structures of nanotubes give rise to different functional properties. Thus, membrane nanotubes between macrophages are more complex than unvarying ubiquitous membrane tethers and facilitate several means for distal interactions between immune cells.

16 April 2002 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
MBMartin Booth
Martin Booth
MNMark A. A. Neil
Mark A. A. Neil
RJRimas Juškaitis
Rimas Juškaitis
TWTony Wilson
Tony Wilson
The main advantage of confocal microscopes over their conventional counterparts is their ability to optically “section” thick specimens; the thin image slices thus obtained can be used to reconstruct three-dimensional images, a capability which is particularly useful in biological applications. However, it is well known that the resolution and optical sectioning ability can be severely degraded by system or specimen-induced aberrations. The use of high aperture lenses further exacerbates the problem. Moreover, aberrations can considerably reduce the number of photons that reach the detector, leading to lower contrast. It is rather unfortunate, therefore, that in practical microscopy, aberration-free confocal imaging is rarely achieved. Adaptive optics systems, which have been used widely to correct aberrations in astronomy, offer a solution here but also present new challenges. The optical system and the source of aberrations in a confocal microscope are considerably different and require a novel approach to wavefront sensing. This method, based upon direct measurement of Zernike aberration modes, also exhibits an axial selectivity similar to that of a confocal microscope. We demonstrate an adaptive confocal fluorescence microscope incorporating this modal sensor together with a deformable membrane mirror for aberration correction. Aberration corrected images of biological specimens show considerable improvement in contrast and apparent restoration of axial resolution.

4 December 2008 in Analytical Chemistry
Verified
Journal Article
Closed access
YSYolanda Schaerli
Yolanda Schaerli
RWRobert C. Wootton
Robert C. Wootton
Tom RobinsonTom Robinson
Tom Robinson
VSViktor Stein
Viktor Stein
CDChristopher Dunsby
Christopher Dunsby
FHFlorian Hollfelder
Florian Hollfelder

1 November 1998 in Journal of Microscopy
Verified
Journal Article
Closed access
PDF file
MBM.J. Booth
M.J. Booth
MNM.A.A. Neil
M.A.A. Neil
TWT. Wilson
T. Wilson

14 January 2010 in Journal of Neural Engineering
Verified
Journal Article
Closed access
NGNir Grossman
Nir Grossman
VPVincent Poher
Vincent Poher
MGMatthew S Grubb
Matthew S Grubb
GKGordon T Kennedy
Gordon T Kennedy
KNKonstantin Nikolic
Konstantin Nikolic
Patrick A G DegenaarPatrick A G Degenaar
Patrick A G Degenaar
Studying neuronal processes such as synaptic summation, dendritic physiology and neural network dynamics requires complex spatiotemporal control over neuronal activities. The recent development of neural photosensitization tools, such as channelrhodopsin-2 (ChR2), offers new opportunities for non-invasive, flexible and cell-specific neuronal stimulation. Previously, complex spatiotemporal control of photosensitized neurons has been limited by the lack of appropriate optical devices which can provide 2D stimulation with sufficient irradiance. Here we present a simple and powerful solution that is based on an array of high-power micro light-emitting diodes (micro-LEDs) that can generate arbitrary optical excitation patterns on a neuronal sample with micrometre and millisecond resolution. We first describe the design and fabrication of the system and characterize its capabilities. We then demonstrate its capacity to elicit precise electrophysiological responses in cultured and slice neurons expressing ChR2.