15 August 2024 in Physical Review Accelerators and Beams
This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix.
1 September 2024 in Journal of Instrumentation
Electrons emitted via field emission during superconducting (SC) radio-frequency (RF) cavity tests at vertical test stands often collide with the iris region inside the cavity, generating X-rays at these locations. In 1.3 GHz 9-cell SC RF cavities designed for the International Linear Collider (ILC), stiffener rings located outside the iris region between cells can interfere with X-ray detection, complicating the precise identification of field emission sites. Hence, we developed a high-density strip X-ray mapping systems (sX-map) that can be inserted into the iris region of ILC-type 9-cell SC RF cavities. This sX-map facilitates efficient and accurate detection of X-rays generated near the irises, unaffected by the presence of stiffener rings. The sX-map consisted of 32 sensors per strip, with sensors spaced approximately 10 mm apart. It was deployed in every iris of the 9-cell cavity, using a total of 320 sensors. A multiplexer was employed to facilitate the readout of a large number of detectors using a minimal number of signal lines, connecting the strips inside within the vertical test cryostat. In a vertical test conducted at Jefferson Lab (JLab), we demonstrated the capability of sX-map to detect X-rays despite the presence of a stiffener ring. This paper presents the detailed design of the sX-map and the results from the vertical test at JLab.
1 December 2024 in Journal of Instrumentation