Min Dai

Min Dai

Auto-generated profile, based on publicly available information

Min Dai

Fudan Tyndall Center and Shanghai Key Laboratory of Atmospheric Particle Pollution and Prevention (LAP3, Department of Environmental Science and Engineering, Fudan University, Shanghai 200438, China

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2021 in Energy
Verified
Journal Article
Closed access
LYLan Yang
Lan Yang
Xue-Chao WangXue-Chao Wang
Xue-Chao Wang
MDMin Dai
Min Dai
BCBin Chen
Bin Chen
YQYuanbo Qiao
Yuanbo Qiao
YWYutao Wang
Yutao Wang

17 August 2023 in Resources, Conservation and Recycling
Verified
Journal Article
Closed access
MDMin Dai
Min Dai
MSMingxing Sun
Mingxing Sun
BCBin Chen
Bin Chen
HXHongyi Xie
Hongyi Xie
DZDingfan Zhang
Dingfan Zhang
YWYutao Wang
Yutao Wang

27 February 2024 in Environmental Science & Technology
Verified
Journal Article
Closed access
HXHongyi Xie
Hongyi Xie
BCBin Chen
Bin Chen
MDMin Dai
Min Dai
ZHZhixiu Han
Zhixiu Han
YBYixuan Bai
Yixuan Bai
YWYutao Wang
Yutao Wang

29 August 2021 in Journal of Industrial Ecology
Verified
Journal Article
Closed access
PDF file
WXWei Xie
Wei Xie
HYHuajun Yu
Huajun Yu
YLYang Li
Yang Li
MDMin Dai
Min Dai
XLXinyi Long
Xinyi Long
YWYutao Wang
Yutao Wang

1 December 2021 in Resources, Conservation and Recycling
Verified
Journal Article
Closed access
LDLinlin Duan
Linlin Duan
YLYupeng Liu
Yupeng Liu
YYYi Yang
Yi Yang
LSLulu Song
Lulu Song
MHMin Hao
Min Hao
WCWei-Qiang Chen
Wei-Qiang Chen

28 May 2021
Verified
Conference Paper
Closed access
BWBaoquan Wan
Baoquan Wan
MDMin Dai
Min Dai
LWLei Wang
Lei Wang
JLJianben Liu
Jianben Liu
YZYanze Zhang
Yanze Zhang
XCXiaoyue Chen
Xiaoyue Chen
In the research of Very Fast Transient Overvoltage(VFTO), the accuracy of arc model of disconnector largely influences the VFTO calculation results. How to accurately simulate the striking and extinguishing process of the arc during the action of the disconnector is the key issue of studying arc model. In this paper, the ATP-EMTP electromagnetic transient program was used to simulate the arc damping by series connection of constant resistance and time-varying inductance, and the built-in MODELS module was used for programming to simulate the restriking process of the arc. The model was applied to a 1000kV GIS test circuit. The voltage and current waveforms were analyzed under the opening and closing operations of the model, and the results were compared with the single breakdown arc model. At the same time, combined with the restriking arc model, the influence of opening speed of disconnector on VFTO was analyzed. The present study suggests that the restriking arc model can better reflect the VFTO characteristics during the breakdown process of disconnector. When the opening speed is less than 0.7m/s, the maximum VFTO of the test circuit increases with the increase of opening speed. When the VFTO amplitude reaches the maximum, it will decrease with the further increase of opening speed.