Humidity is a critical factor in atmospheric corona discharge. Fluid dynamics models have become a common method to explore the detailed corona discharge characteristics in humid air. However, the models require the specification of some key parameters, such as electron swarm parameters and Townsend coefficients, which strongly depend on the electron energy distribution function (EEDF). In this paper, the EEDFs of dry air and water vapor are compared by solving the electron Boltzmann equation using classical the two-term approximation. Moreover, electron drift velocity in dry air and water vapor are compared and validated. Finally, effects of humidity on the electron swarm parameters and Townsend coefficients are also discussed. The results show that the electron drift velocity in dry air and water vapor in this paper is well consistent with the previous experimental results for a wide range. It is concluded that the humidity could increase the electron mobility coefficient and decrease the electron diffusion coefficient in low reduced electric field, which are insensitive to humidity in high reduced electric field. The strength of ionization and attachment reactions are both enhanced by humidity, and the corona onset electric fields increase with the increase in humidity.
26 July 2022 in IEEE Transactions on Industry Applications
In the research process of Very Fast Transient Over-voltage(VFTO), the accuracy of the switching arc model largely determines the calculation results of VFTO. How to more accurately simulate the arc striking and extinguishing process of the arc during the action of the disconnector is the key issue in the study of arc model. In this paper, the ATP-EMTP electromagnetic transient program was used to simulate arc damping with a series connection of a fixed-value resistance and a time-varying inductance, and the built-in MODELS module was used for programming to simulate the reignition and extinguishing process of the arc based on the gaseous dielectric theory and the energy balance theory. The model was applied to a 1000kV GIS test circuit. The relationship between arc damping and arc voltage and current was analyzed, and the arc reignition law during opening and closing is studied. The arcing law obtained is compared with the experimental results of the existing literature, and the accuracy of the simulation model is verified. Simultaneously, the influence of opening speed of disconnector on VFTO was analyzed by simulation. The results show that when the opening speed is less than 0.7m/s, the maximum value of VFTO in test circuit increases with the increase of opening speed. After the VFTO amplitude reaches the maximum, continue to increase the opening speed, the VFTO amplitude decreases. This law is consistent with the experimental results of the existing literature, which proves that the arc model built in this paper has certain engineering application value.
The outdoor ultra-high voltage (UHV) dry-type air-core smoothing reactors (DASR) of High Voltage Direct Current systems are equipped with a rain cover and an acoustic enclosure. To study the convective heat transfer between the DASR and the surrounding air, this paper presents a coupled model of the temperature and fluid field based on the structural features and cooling manner. The resistive losses of encapsulations calculated by finite element method (FEM) were used as heat sources in the thermal analysis. The steady fluid and thermal field of the 3-D reactor model were solved by the finite volume method (FVM), and the temperature distribution characteristics of the reactor were obtained. Subsequently, the axial and radial temperature distributions of encapsulation were investigated separately. Finally, an optical fiber temperature measurement scheme was used for an UHV DASR under natural convection conditions. Comparative analysis showed that the simulation results are in good agreement with the experimental data, which verifies the rationality and accuracy of the numerical calculation. These results can serve as a reference for the optimal design and maintenance of UHV DASRs.
9 November 2017 in IEEE Transactions on Electromagnetic Compatibility
Radio interference (RI) induced by the corona discharge of alternating current transmission lines is more severe at high altitudes than at low altitudes; hence, RI is a crucial limiting factor in the structural design of transmission lines and environmental impact assessments. To determine RI performance at high altitudes, the State Grid Corporation of China constructed an ultrahigh-voltage (UHV) corona cage in Xining in 2015 at an altitude of 2261 m. In this study, the cage was used to investigate a high number of bundled conductors under heavy rain. An RI excitation function was derived from Xining and the effects of several variables on RI performance were analyzed. In addition, RI altitude corrections were studied by comparing the Xining data with data obtained from a UHV corona cage in Wuhan located at an altitude of 23 m. The RI correction value was verified not to be a constant value but rather one that changed with the surface electric field and bundle size. The correction values obtained in this paper could enable the RI levels of high-voltage alternating current transmission lines at high altitudes to be evaluated more precisely.
5 April 2020 in Environmental Science and Pollution Research
Compared with other lightning targets on the ground, the most notable feature of a wind turbine is that the blades are usually in a rotating state when lightning strikes. To study the mechanism of blade rotation influencing wind turbine on triggering lightning, lightning discharge comparison tests based on a typical 2-MW 1:30-scaled wind turbine model with an arching high-voltage electrode were conducted under different modes of stationary and rotating blades. Negative polarity switching impulses of 250/2500 μs were applied to the arching electrode. The up-and-down method was adopted for 50% discharge voltage and the discharge process was observed. The experimental results showed that under the condition of a 4 m gap, the breakdown voltage decreases and the connection point of the leaders approaches the high-voltage electrode with increasing blade speed, indicating that the wind turbine’s blade rotation enhances the triggering of lightning. The analysis showed that the blade rotation could be altering the charge distribution on the blade tip, resulting in varied ascending leader development on the blade tip, which affected the discharge development process.