Multi-walled carbon nanotubes (MWCNT) were used to separate amoxicillin from aqueous media. The parameters affecting amoxicillin adsorption such as pH, temperature, time, interferences of similar molecules, and the amount of adsorbent used were studied. Amoxicillin adsorption using MWCNT was compared to that using Fullerene C60 and activated carbon (AC). The adsorption efficiency of 0.1 and 0.2 g of MWCNT using in a continuous mode were 86.5% and 87.9%, respectively. Evaluation of the adsorbent capacity showed that each gram of MWCNT can absorb 22.9 mg amoxicillin. The effect of pH was studied over the range 2–8 and revealed that adsorption of the amoxicillin at the initial pH of 4.6 was more effective than any other pH. The adsorption of amoxicillin on MWCNT was much greater than Fullerene C60 and AC. Adsorption data showed that they were best fitted to the Langmuir isotherm.
The present work deals with the preparation of NiO/Co3O4 nanocomposites in presence of ultrasonic irradiation, and its use in electrochemical determination of Parkinson's drugs. NiO/Co3O4 nanocomposites are prepared using ultrasound assisted method. The impact of ultrasonic irradiation power (0, 75, 150, 300 and 600 W) on the structure and morphology of NiO/Co3O4 nanocomposites was investigated. Various particle morphologies were attained because of the existence of ultrasonic irradiation. The nanoparticles' structure exhibited more uniformity whilst the particles sizes and nanoparticle accumulation was reduced when ultrasonic irradiation power was increased. The NiO/Co3O4 nanocomposite was determined via X-ray diffraction, scanning electron microscopy i.e. SEM as well as energy dispersion X-ray spectroscopy (EDX). Drop casting NiO/Co3O4 nanocomposites suspension on glassy carbon electrode was employed to fabricate the modified glassy carbon electrode (NiO/Co3O4/GCE). The electrochemical studies on the NiO/Co3O4 nanocomposite towards droxidopa and carbidopa were experimented via cyclic voltammetry (CV), chronoamperometry (CHA) and differential pulse voltammetry (DPV). The CV examinations displayed increased catalytic behavior of droxidopa because of synergistic impact of the nanocomposite that was bolstered through enhanced material surface roughness. By using differential pulse voltammetry, the droxidopa detection limit and linear range was determined as 0.01 μM and 0.1-500.0 μM, respectively. Also, the adjusted electrode was implemented to ascertain droxidopa in the presence of carbidopa by differential pulse voltammetry. This sensor exhibited long term reproducibility and stability. Droxidopa and carbidopa quantification within biological specimens of fluids i.e. human urine and serum were conducted to validate the suitability in the application of this sensor.