24 February 2022 in Neoplasia
Tumor microvascular responses may provide a sensitive readout indicative of radiation therapy efficacy, its time course and dose dependencies. However, direct high-resolution observation and longitudinal monitoring of large-scale microvascular remodeling in deep tissues remained challenging with the conventional microscopy approaches.
11 October 2022 in Biomedical Optics Express
The research is devoted to comparison of the blood vessel structure and the oxygen state of three xenografts: SN-12C, HCT-116 and Colo320. Differences in the vessel formation and the level of oxygenation are revealed by optoacoustic (OA) microscopy and diffuse optical spectroscopy (DOS) respectively. The Colo320 tumor is characterized by the highest values of vessel size and fraction. DOS showed increased content of deoxyhemoglobin that led to reduction of saturation level for Colo320 as compared to other tumors. Immunohistochemical (IHC) analysis for CD31 demonstrates the higher number of vessels in Colo320. The IHC for hypoxia was consistent with DOS results and revealed higher values of the relative hypoxic fraction in Colo320.
17 May 2024 in Ultrasonics
Piezoelectric detectors are integral part of modern ultrasound imaging systems. Their utility has also been extended beyond the established methodologies into the emerging realm of hybrid optoacoustic imaging. Conventional piezoceramic detectors, however, struggle to combine high detection sensitivity with ultrawide bandwidth, both considered critical for attaining optimal optoacoustic imaging performance. Our research, both theoretical and empirical, unveils that damped piezopolymer detectors fabricated from PVDF-TrFE are markedly capable of achieving a synergistic blend between broad bandwidth and superb sensitivity. Experimental evaluations reflected an average sensitivity of 15.5 µV/Pa within a 1-10 MHz band for a 120 µm thick detector and 6.4 µV/Pa within a 1-30 MHz band for a 20 µm thick detector, thus outperforming conventional piezoelectric analogues. The resultant noise equivalent pressure (NEPs) values were 0.3 Pa and 1.2 Pa for the 20 µm and 120 µm detectors, respectively. Our findings herald a significant stride towards enhancing the efficacy of ultrawideband ultrasound and optoacoustic imaging systems.
10 September 2025 in Biomedical Optics Express
Optical resolution optoacoustic (or photoacoustic) microscopy (OR-OAM) utilizing a 532 nm laser wavelength represents a promising approach for non-invasive visualization of superficial hemoglobin-rich structures. However, clinical translation of OR-OAM angiography typically faces a trade-off between achieving high contrast and resolution versus maintaining an extended depth-of-field at safe laser exposure levels. Gradient refractive index (GRIN) fiber lenses can provide an elongated optical focus preserved over a millimeter-scale length. However, developing coaxially aligned wideband acoustic detectors with high sensitivity remains challenging. Here, we introduce a piezopolymer PVDF-TrFE detector featuring a spherically-focused thin (100 μm) ring geometry with a 4.6 mm aperture and 1.5 mm working distance (NA = 0.84). Numerical modeling reveals not only an extended depth of field, but also an improvement in sensitivity compared to conventional full-aperture detectors. In vitro experiments using whole human blood demonstrated a 14 dB signal-to-noise ratio at a safe laser irradiance of 20 mJ/cm2. In vivo angiographic imaging of neonatal mouse cerebral vasculature and human cuticle confirmed the detector's capability to achieve a depth-of-field exceeding 1 mm, highlighting its potential for a broad range of biomedical applications.