Atabak Najafi

Atabak Najafi

Auto-generated profile, based on publicly available information

Atabak Najafi

Department of Anesthesiology and Critical Care Sina Hospital Tehran University of Medical Sciences Tehran Iran tums.ac.ir

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Case Reports in Critical Care
Verified
Journal Article
Open access
PDF file
MMMojtaba Mojtahedzadeh
Mojtaba Mojtahedzadeh
FNFarhad Najmeddin
Farhad Najmeddin
EPElham Pourheidar
Elham Pourheidar
ANAtabak Najafi
Atabak Najafi
RBReza Bahman
Reza Bahman
RHRezvan Hassanpour
Rezvan Hassanpour
Clostridium botulinum produces the most potent bacterial toxin, botulinum toxin A (BTXA), which has various therapeutic and cosmetic indications. Intragastric BTXA injection is a new obesity treatment method that was argued to be safe due to the inactivation of BTXA through the liver or metabolization within the gastric wall. However, a 36‐year‐old woman was admitted to the intensive care unit (ICU) due to developing botulism as a result of an intragastric injection of BTXA. The diplopia, headaches, ptosis, decreased muscle force, and respiratory distress two days after injection were her first chief complaints, and also, she experienced significant dysphagia, hoarse voice, thick tongue, constipation, hyposmia, and hypogeusia after two weeks. This case report highlights the necessity for physicians to have sufficient information about this method and consider possible life‐threatening adverse effects including botulism.

1 May 2015
Verified
Conference Paper
Closed access
ANAtabak Najafi
Atabak Najafi
BDBurak Dokmetas
Burak Dokmetas
IIIres Iskender
Ires Iskender
Transformers illustrate the majority of capital investment in transmission and distribution centers. Additionally, interruptions of power transformer have a significant economic effects on the performance of an electrical network. For this reason, the safe and reliable performance of transformer, directly related to the security and stability of power system. This paper studies the growth of leakage flux and stray losses in the tank wall and core clamp of distribution transformer under unbalanced voltage condition. The computer-based simulation utilizing the three dimensional FEM that improved in Ansoft - Maxwell and surface impedances method as a tool for visualizing the leakage flux and stray losses on tank wall and core clamp of distribution transformers. FEM is one among popular numerical methods that is able to handle problem complexity in various forms.

3 June 2020 in Konya Journal of Engineering Sciences
Verified
Journal Article
Open access
PDF file
ANAtabak Najafi
Atabak Najafi
Tr en Endüstri ve dağıtım merkezlerinde yaygın olarak kullanılan dağıtım trafoları, gerilim dengesizliğinden ve harmonik yüklerden en fazla etkilenen elektrik makinalarıdır. Bu durumlar dağıtım trafoların verimini, nüve kaybı ve bakır kaybı gibi parametreleri üzerinde olumsuz etkisi vardır. Bu makalede, harmonikli yükler ve dengesiz besleme gerilimi koşulları altında Dağıtım Trafosunun İndirgenmesi ve kayıplardaki artış incelenmiştir. Transformatörün indirgemesini gerçekleştirmek için kfaktörü ve harmonik kayıp faktörü (HFL) kullanılmıştır. Bu çalışmada dağıtım transformatörünün sargılarında ve çekirdeğinde oluşan manyetik akı yoğunluğunu gözlemlemek için üç boyutlu zaman adımlı sonlu elemanlar yönteminden (ZASEY) faydalanılmıştır. Elde edilen sonuçlara göre IEEE standardının yüksek harmonikli akım (THDI) ve dengesiz koşulları altında transformatörün indirgenmesi için yetersiz, ZASEY’nin ise daha uygun doğru bir yöntem olduğu görülmüştür. Distribution transformers which are widely used in industry and distribution centers are the most affected by voltage imbalance and harmonic loads. These situations have a negative impact on efficiency , core loss and winding loss of distribution transformers, In this article, derating as well as losses increase of transformer under non-linear loads and imbalanced supply voltage conditions are examined . harmonic loss factor (HFL) and K-factor have been used to perform the transformer derating. In this study, 3D time-step finite element method(TSFEM) used to observe the magnetic flux density formed in the windings and core of the distribution transformer. According to the results obtained, it is seen that the IEEE standard is insufficient for the derating of the transformer under high harmonic current (THDI) and unbalanced conditions and Time Stepping Finite Element Method is a more suitable method.