1 January 2024 in Case Reports in Critical Care
Clostridium botulinum produces the most potent bacterial toxin, botulinum toxin A (BTXA), which has various therapeutic and cosmetic indications. Intragastric BTXA injection is a new obesity treatment method that was argued to be safe due to the inactivation of BTXA through the liver or metabolization within the gastric wall. However, a 36‐year‐old woman was admitted to the intensive care unit (ICU) due to developing botulism as a result of an intragastric injection of BTXA. The diplopia, headaches, ptosis, decreased muscle force, and respiratory distress two days after injection were her first chief complaints, and also, she experienced significant dysphagia, hoarse voice, thick tongue, constipation, hyposmia, and hypogeusia after two weeks. This case report highlights the necessity for physicians to have sufficient information about this method and consider possible life‐threatening adverse effects including botulism.
3 June 2020 in Konya Journal of Engineering Sciences
Tr en Endüstri ve dağıtım merkezlerinde yaygın olarak kullanılan dağıtım trafoları, gerilim dengesizliğinden ve harmonik yüklerden en fazla etkilenen elektrik makinalarıdır. Bu durumlar dağıtım trafoların verimini, nüve kaybı ve bakır kaybı gibi parametreleri üzerinde olumsuz etkisi vardır. Bu makalede, harmonikli yükler ve dengesiz besleme gerilimi koşulları altında Dağıtım Trafosunun İndirgenmesi ve kayıplardaki artış incelenmiştir. Transformatörün indirgemesini gerçekleştirmek için kfaktörü ve harmonik kayıp faktörü (HFL) kullanılmıştır. Bu çalışmada dağıtım transformatörünün sargılarında ve çekirdeğinde oluşan manyetik akı yoğunluğunu gözlemlemek için üç boyutlu zaman adımlı sonlu elemanlar yönteminden (ZASEY) faydalanılmıştır. Elde edilen sonuçlara göre IEEE standardının yüksek harmonikli akım (THDI) ve dengesiz koşulları altında transformatörün indirgenmesi için yetersiz, ZASEY’nin ise daha uygun doğru bir yöntem olduğu görülmüştür. Distribution transformers which are widely used in industry and distribution centers are the most affected by voltage imbalance and harmonic loads. These situations have a negative impact on efficiency , core loss and winding loss of distribution transformers, In this article, derating as well as losses increase of transformer under non-linear loads and imbalanced supply voltage conditions are examined . harmonic loss factor (HFL) and K-factor have been used to perform the transformer derating. In this study, 3D time-step finite element method(TSFEM) used to observe the magnetic flux density formed in the windings and core of the distribution transformer. According to the results obtained, it is seen that the IEEE standard is insufficient for the derating of the transformer under high harmonic current (THDI) and unbalanced conditions and Time Stepping Finite Element Method is a more suitable method.