Ping-Cheng Ku

Ping-Cheng Ku

Auto-generated profile, based on publicly available information

Ping-Cheng Ku

Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 July 2020 in IEEE Access
Verified
Journal Article
Open access
KCKu Ping Cheng
Ku Ping Cheng
RMRajesh Elara Mohan
Rajesh Elara Mohan
NNNguyen Huu Khanh Nhan
Nguyen Huu Khanh Nhan
ALAnh Le
Anh Le
Reconfigurable robots have received broad research interest due to the high dexterity they provide and the complex actions they could perform. Robots with reconfigurability are perfect candidates in tasks like exploration or rescue missions in environments with complicated obstacle layout or with dynamic obstacles. However, the automation of reconfigurable robots is more challenging than fix-shaped robots due to the increased possible combinations of robot actions and the navigation difficulty in obstacle-rich environments. This paper develops a systematic strategy to construct a model of hinged-Tetromino (hTetro) reconfigurable robot in the workspace and proposes a genetic algorithm-based method (hTetro-GA) to achieve path planning for hTetro robots. The proposed algorithm considers hTetro path planning as a multi-objective optimization problem and evaluates the performance of the outcome based on four customized fitness objective functions. In this work, the proposed hTetro-GA is tested in six virtual environments with various obstacle layouts and characteristics and with different population sizes. The algorithm generates Pareto-optimal solutions that achieve desire robot configurations in these settings, with O-shaped and I-shaped morphologies being the more efficient configurations selected from the genetic algorithm. The proposed algorithm is implemented and tested on real hTetro platform, and the framework of this work could be adopted to other robot platforms with multiple configurations to perform multi-objective based path planning.

4 August 2022 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
CGCong Gao
Cong Gao
HPHenry Phalen
Henry Phalen
AMAdam Margalit
Adam Margalit
JMJustin H. Ma
Justin H. Ma
PKPing-Cheng Ku
Ping-Cheng Ku
MAMehran Armand
Mehran Armand
We present an autonomous robotic spine needle injection system using fluoroscopic image-based navigation. Our system includes patient-specific planning, intra-operative image-based 2D/3D registration and navigation, and automatic robot-guided needle injection. We performed intensive simulation studies to validate the registration accuracy. We achieved a mean spine vertebrae registration error of 0.8± 0.3 mm, 0.9± 0.7 degrees, mean injection device registration error of 0.2± 0.6 mm, 1.2± 1.3 degrees, in translation and rotation, respectively. We then conducted cadaveric studies comparing our system to an experienced clinician’s free-hand injections. We achieved a mean needle tip translational error of $5.1~\pm ~2.4$ mm and needle orientation error of $3.6~\pm ~1.9$ degrees for robotic injections, compared to 7.6± 2.8 mm and 9.9± 4.7 degrees for clinician’s free-hand injections, respectively. During injections, all needle tips were placed within the defined safety zones for this application. The results suggest the feasibility of using our image-guided robotic injection system for spinal orthopedic applications.

15 December 2022 in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
Verified
Journal Article
Closed access
PKPing-Cheng Ku
Ping-Cheng Ku
AMAlejandro Martin-Gomez
Alejandro Martin-Gomez
CGCong Gao
Cong Gao
RGRobert Grupp
Robert Grupp
SMSimon C. Mears
Simon C. Mears
MAMehran Armand
Mehran Armand
Magnetic Resonance Imaging (MRI) is a medical imaging modality that allows for the evaluation of soft-tissue diseases and the assessment of bone quality. Preoperative MRI volumes are used by surgeons to identify defected bones, perform the segmentation of lesions, and generate surgical plans before the surgery. Nevertheless, conventional intraoperative imaging modalities such as fluoroscopy are less sensitive in detecting potential lesions. In this work, we propose a 2D/3D registration pipeline that aims to register preoperative MRI with intraoperative 2D fluoroscopic images. To showcase the feasibility of our approach, we use the core decompression procedure as a surgical example to perform 2D/3D femur registration. The proposed registration pipeline is evaluated using digitally reconstructed radiographs (DRRs) to simulate the intraoperative fluoroscopic images. The resulting transformation from the registration is later used to create overlays of preoperative MRI annotations and planning data to provide intraoperative visual guidance to surgeons. Our results suggest that the proposed registration pipeline is capable of achieving reasonable transformation between MRI and digitally reconstructed fluoroscopic images for intraoperative visualisation applications.

1 January 2026 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YSYudi Sang
Yudi Sang
YLYanzhen Liu
Yanzhen Liu
SYSutuke Yibulayimu
Sutuke Yibulayimu
YWYunning Wang
Yunning Wang
BKBenjamin D. Killeen
Benjamin D. Killeen
YWYu Wang
Yu Wang
The segmentation of pelvic fracture fragments in CT and X-ray images is crucial for trauma diagnosis, surgical planning, and intraoperative guidance. However, accurately and efficiently delineating the bone fragments remains a significant challenge due to complex anatomy and imaging limitations. The PENGWIN challenge, organized as a MICCAI 2024 satellite event, aimed to advance automated fracture segmentation by benchmarking state-of-the-art algorithms on these complex tasks. A diverse dataset of 150 CT scans was collected from multiple clinical centers, and a large set of simulated X-ray images was generated using the DeepDRR method. Final submissions from 16 teams worldwide were evaluated under a rigorous multi-metric testing scheme. The top-performing CT algorithm achieved an average fragment-wise intersection over union (IoU) of 0.930, demonstrating satisfactory accuracy. However, in the X-ray task, the best algorithm achieved an IoU of 0.774, which is promising but not yet sufficient for intra-operative decision-making, reflecting the inherent challenges of fragment overlap in projection imaging. Beyond the quantitative evaluation, the challenge revealed methodological diversity in algorithm design. Variations in instance representation, such as primary-secondary classification versus boundary-core separation, led to differing segmentation strategies. Despite promising results, the challenge also exposed inherent uncertainties in fragment definition, particularly in cases of incomplete fractures. These findings suggest that interactive segmentation approaches, integrating human decision-making with task-relevant information, may be essential for improving model reliability and clinical applicability.

30 May 2025 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
PKPing-Cheng Ku
Ping-Cheng Ku
MLMingxu Liu
Mingxu Liu
RGRobert Grupp
Robert Grupp
AHAndrew Harris
Andrew Harris
JOJulius K. Oni
Julius K. Oni
MAMehran Armand
Mehran Armand