Amulya Kumar Sanyasi

Amulya Kumar Sanyasi

Auto-generated profile, based on publicly available information

Amulya Kumar Sanyasi

Institute for Plasma Research 1 , Gandhinagar 382428

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2017 in Physics of Plasmas
Verified
Journal Article
Closed access
PSPrabhakar Srivastav
Prabhakar Srivastav
RSRameswar Singh
Rameswar Singh
LAL. M. Awasthi
L. M. Awasthi
ASA. K. Sanyasi
A. K. Sanyasi
PSP. K. Srivastava
P. K. Srivastava
PKP. K. Kaw
P. K. Kaw
Radially inward turbulent particle flux is observed in the core region of target plasma of Large Volume Plasma Device where electron temperature gradient (ETG) driven turbulence conditions are satisfied with threshold, ηETG=Ln/LT>2/3 [Mattoo et al., Phys. Rev. Lett. 108, 255007 (2012)]. The observed mode satisfies the scale length and frequency ordering of ETG (k⊥ρe≤1≪k⊥ρi,Ωi<ω≪Ωe) , where k⊥ is the perpendicular wave vector, ρe ,ρi are Larmor radii of electron and ion, respectively, and Ωi,Ωe , and ω are the ion, electron gyro frequencies, and the mode frequency, respectively. The measured flux is dominantly electrostatic (Γes≈105Γem ), although the nature of the turbulence is electromagnetic (β∼0.1−0.6) . Experimental observations of the phase angle between density and potential fluctuations, θñ,ϕ̃ , and turbulent particle flux, Γes , shows good agreement with the theoretical estimations derived for ETG turbulence.

1 October 2017 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
ASA. K. Sanyasi
A. K. Sanyasi
LAL. M. Awasthi
L. M. Awasthi
PSP. K. Srivastava
P. K. Srivastava
SMS. K. Mattoo
S. K. Mattoo
DSD. Sharma
D. Sharma
PKP. K. Kaw
P. K. Kaw
This paper reports experimental and theoretical investigations on plasma turbulence in the source plasma of a Large Volume Plasma Device. It is shown that a highly asymmetrical localized thin rectangular slab of strong plasma turbulence is excited by loss cone instability. The position of the slab coincides with the injection line of the primary ionizing energetic electrons. Outside the slab, in the core, the turbulence is weaker by a factor of 30 . The plasma turbulence consists of oblique [θ=tan−1(k⊥/k||)≈87° ] Quasi-Longitudinal (QL) electromagnetic whistlers in a broad band of 40kHz<f≤80 kHz with k⊥∼1.2 cm−1 and k||∼0.06cm−1 . Experimental observations suggest that the primary agent for the turbulence is not driven by primary ionizing energetic electrons but by the loss cone feature in the velocity distribution of reflected energetic electrons. A magnetic mirror is formed in the Electron Energy Filter when it is energized. It is shown that it is this mirror which is responsible for both reflection of the energetic electrons and imposing loss cone feature on it. Theoretical framework is based upon Oblique whistler approximation by Sharma and Vlahos [Astrophys. J. 280, 405 (1984)] and Verkhoglyadova et al. [J. Geophys. Res. 115, A00F19 (2010)] and Quasi Longitudinal (QL) whistlers by Booker and Dyce [Radio Sci. J. Res 69D (1965)] for excitation of the plasma turbulence in the magnetosphere.

1 May 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ASA. K. Sanyasi
A. K. Sanyasi
RSR. Sugandhi
R. Sugandhi
PSP. K. Srivastava
P. K. Srivastava
PSPrabhakar Srivastav
Prabhakar Srivastav
LAL. M. Awasthi
L. M. Awasthi
An automated electro-mechanical system for the positioning of plasma diagnostics has been designed and implemented in a Large Volume Plasma Device (LVPD). The system consists of 12 electro-mechanical assemblies, which are orchestrated using the Modbus communication protocol on 4-wire RS485 communications to meet the experimental requirements. Each assembly has a lead screw-based mechanical structure, Wilson feed-through-based vacuum interface, bipolar stepper motor, micro-controller-based stepper drive, and optical encoder for online positioning correction of probes. The novelty of the system lies in the orchestration of multiple drives on a single interface, fabrication and installation of the system for a large experimental device like the LVPD, in-house developed software, and adopted architectural practices. The paper discusses the design, description of hardware and software interfaces, and performance results in LVPD.

1 October 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ASA. K. Sanyasi
A. K. Sanyasi
PSP. K. Srivastava
P. K. Srivastava
AAAyan Adhikari
Ayan Adhikari
LAL. M. Awasthi
L. M. Awasthi
PLP. Leuva
P. Leuva
RSR. Sugandhi
R. Sugandhi
This paper discusses the salient features and plasma performance of the newly installed Large Area Multi-Filamentary Plasma Source (LAMPS) in large volume plasma device–upgrade. The plasma source is designed to exhibit a plasma electron density of ∼1018 m−3, low electron temperature (∼eV), and a uniform plasma cross section of 2.54 m2. The directly heated LAMPS emits accelerated primary energetic electrons when it is biased with a negative discharge voltage with respect to the anode. The hairpin shaped tungsten (W) filaments, each of diameter 0.5 mm and length 180 mm, are heated to a temperature of 2700 K by feeding ∼19.5A to each filament. The LAMPS consists of 162 numbers of filaments, and it has been successfully operated with a total investment of 50 kW of electrical power. The LAMPS as a laboratory plasma source is characterized by large operational life, ease of handling, better compatibility to high pressure conditions, and advantages over other contemporary plasma sources, viz., oxide coated cathodes, RF based sources, and helicon sources, when producing plasma over large cross sections and fill volumes. Pulsed argon plasma is produced with quiescence (δnene≪1% ) using LAMPS for the duration of 50 ms and a reasonably good radial uniformity (Ln = 210 cm) is achieved. Good axial uniformity is also observed over the entire length of the device. Initial measurements on plasma parameters have yielded plasma density of ∼2×1017m−3 with existing set of filaments. A plasma density of ∼1018 m−3 is envisaged for larger thickness of filaments, such as 0.75 and 1.0 mm, with the existing plasma source assembly setup.

10 September 2018 in Materials Research Express
Verified
Journal Article
Closed access
SCSachin S Chauhan
Sachin S Chauhan
USUttam Sharma
Uttam Sharma
JSJayshree Sharma
Jayshree Sharma
ASA K Sanyasi
A K Sanyasi
JGJ Ghosh
J Ghosh
SGS K Ghosh
S K Ghosh

1 August 2020 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
PAPrince Alex
Prince Alex
ASA K Sanyasi
A K Sanyasi
PSPrabhakar Srivastav
Prabhakar Srivastav
LAL M Awasthi
L M Awasthi
PSP K Srivastava
P K Srivastava
RSRitesh Sugandhi
Ritesh Sugandhi
A double plasma device (DPD) is tested for different operational configurations to identify suitable control for plasma parameters in a weakly ionized, unmagnetized plasma discharge. A separation grid is installed between the two chambers of DPD, which allows filtering of plasma from the first to the second chamber. Investigations are carried out to control the plasma parameters, especially the electron temperature by exploring the role of the grid. The grid bias is varied between −25–0 V and 0–30 V to reflect cooling and heating of plasma. The electron heating and cooling is prominent for the maximum ratio of n source / n target . The electron energy distribution function (EEDF) is obtained to describe the role of grid biasing in controlling the electron temperature in the second chamber. We demonstrated control on the radial profile of electron temperature by charging different radial cross-sections of plasma differently by using a multi-grid assembly system (MGAS). We have also identified the suitable operational regime for DPD where exercising a radial control on electron temperature is possible. Such plasmas can facilitate investigations on electron temperature control for applications in plasma processing, cold–plasma material interaction, etc where low energy electrons are desired.