Pankaj Srivastava

Pankaj Srivastava

Auto-generated profile, based on publicly available information

Pankaj Srivastava

Institute for Plasma Research 1 , Bhat, Gandhinagar 382428, India

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2012 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
SSSushil Kumar Singh
Sushil Kumar Singh
LAL M Awasthi
L M Awasthi
SMS K Mattoo
S K Mattoo
PSP K Srivastava
P K Srivastava
RSR Singh
R Singh
PKP K Kaw
P K Kaw

1 October 2017 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
ASA. K. Sanyasi
A. K. Sanyasi
LAL. M. Awasthi
L. M. Awasthi
PSP. K. Srivastava
P. K. Srivastava
SMS. K. Mattoo
S. K. Mattoo
DSD. Sharma
D. Sharma
PKP. K. Kaw
P. K. Kaw
This paper reports experimental and theoretical investigations on plasma turbulence in the source plasma of a Large Volume Plasma Device. It is shown that a highly asymmetrical localized thin rectangular slab of strong plasma turbulence is excited by loss cone instability. The position of the slab coincides with the injection line of the primary ionizing energetic electrons. Outside the slab, in the core, the turbulence is weaker by a factor of 30 . The plasma turbulence consists of oblique [θ=tan−1(k⊥/k||)≈87° ] Quasi-Longitudinal (QL) electromagnetic whistlers in a broad band of 40kHz<f≤80 kHz with k⊥∼1.2 cm−1 and k||∼0.06cm−1 . Experimental observations suggest that the primary agent for the turbulence is not driven by primary ionizing energetic electrons but by the loss cone feature in the velocity distribution of reflected energetic electrons. A magnetic mirror is formed in the Electron Energy Filter when it is energized. It is shown that it is this mirror which is responsible for both reflection of the energetic electrons and imposing loss cone feature on it. Theoretical framework is based upon Oblique whistler approximation by Sharma and Vlahos [Astrophys. J. 280, 405 (1984)] and Verkhoglyadova et al. [J. Geophys. Res. 115, A00F19 (2010)] and Quasi Longitudinal (QL) whistlers by Booker and Dyce [Radio Sci. J. Res 69D (1965)] for excitation of the plasma turbulence in the magnetosphere.

1 August 2020 in Plasma Sources Science and Technology
Verified
Journal Article
Closed access
PAPrince Alex
Prince Alex
ASA K Sanyasi
A K Sanyasi
PSPrabhakar Srivastav
Prabhakar Srivastav
LAL M Awasthi
L M Awasthi
PSP K Srivastava
P K Srivastava
RSRitesh Sugandhi
Ritesh Sugandhi
A double plasma device (DPD) is tested for different operational configurations to identify suitable control for plasma parameters in a weakly ionized, unmagnetized plasma discharge. A separation grid is installed between the two chambers of DPD, which allows filtering of plasma from the first to the second chamber. Investigations are carried out to control the plasma parameters, especially the electron temperature by exploring the role of the grid. The grid bias is varied between −25–0 V and 0–30 V to reflect cooling and heating of plasma. The electron heating and cooling is prominent for the maximum ratio of n source / n target . The electron energy distribution function (EEDF) is obtained to describe the role of grid biasing in controlling the electron temperature in the second chamber. We demonstrated control on the radial profile of electron temperature by charging different radial cross-sections of plasma differently by using a multi-grid assembly system (MGAS). We have also identified the suitable operational regime for DPD where exercising a radial control on electron temperature is possible. Such plasmas can facilitate investigations on electron temperature control for applications in plasma processing, cold–plasma material interaction, etc where low energy electrons are desired.

1 October 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ASA. K. Sanyasi
A. K. Sanyasi
PSP. K. Srivastava
P. K. Srivastava
AAAyan Adhikari
Ayan Adhikari
LAL. M. Awasthi
L. M. Awasthi
PLP. Leuva
P. Leuva
RSR. Sugandhi
R. Sugandhi
This paper discusses the salient features and plasma performance of the newly installed Large Area Multi-Filamentary Plasma Source (LAMPS) in large volume plasma device–upgrade. The plasma source is designed to exhibit a plasma electron density of ∼1018 m−3, low electron temperature (∼eV), and a uniform plasma cross section of 2.54 m2. The directly heated LAMPS emits accelerated primary energetic electrons when it is biased with a negative discharge voltage with respect to the anode. The hairpin shaped tungsten (W) filaments, each of diameter 0.5 mm and length 180 mm, are heated to a temperature of 2700 K by feeding ∼19.5A to each filament. The LAMPS consists of 162 numbers of filaments, and it has been successfully operated with a total investment of 50 kW of electrical power. The LAMPS as a laboratory plasma source is characterized by large operational life, ease of handling, better compatibility to high pressure conditions, and advantages over other contemporary plasma sources, viz., oxide coated cathodes, RF based sources, and helicon sources, when producing plasma over large cross sections and fill volumes. Pulsed argon plasma is produced with quiescence (δnene≪1% ) using LAMPS for the duration of 50 ms and a reasonably good radial uniformity (Ln = 210 cm) is achieved. Good axial uniformity is also observed over the entire length of the device. Initial measurements on plasma parameters have yielded plasma density of ∼2×1017m−3 with existing set of filaments. A plasma density of ∼1018 m−3 is envisaged for larger thickness of filaments, such as 0.75 and 1.0 mm, with the existing plasma source assembly setup.

1 November 2019 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
PAPrince Alex
Prince Alex
ASA. K. Sanyasi
A. K. Sanyasi
PSPrabhakar Srivastav
Prabhakar Srivastav
PSP. K. Srivastava
P. K. Srivastava
RSR. Sugandhi
R. Sugandhi
LAL. M. Awasthi
L. M. Awasthi
Radial control of the electron temperature gradient is demonstrated in a double plasma device by making use of segmented grid biasing. The plasma produced in the source region is allowed to diffuse into the target region through a single grid as well as through the cassette of multiple grid assembly, under different grid bias conditions. Both electron heating and cooling are observed radially at one location in the target region when a single grid is used. The electrons are cooled down to a temperature of 3.3 eV from 5.1 eV when the grid bias is raised from −25 to 0 V. Similarly, during heating, the electron temperature increases from 4.8 to 7.3 eV when the grid bias is varied between 0 and +20 V. Two different transparencies of grids, 45% transparency (mess-size, m = 0.8 mm ∼ λDe) and 75% transparency (mess-size, m = 2.4 mm > λDe), are used, where the value of λDe ≈ 0.8 mm. The obtained electron energy distribution function suggests that a grid with less transparency is more effective in cooling the electrons because of insignificant energetic electron–neutral collisions in the target region as a sheath in the close vicinity of grid allows only the high energetic electrons to pass through it. The higher transparent grid, on the other hand, produces electron heating as it exerts a negligible influence on the free flow of accelerated high energy electrons to target plasma due to insignificant thermalization. We expanded this concept and, for novelty, applied it to a radially segmented grid assembly of electrically isolated grids, for effectively charging different plasma regions with differently various potentials for exerting a radial control on electron temperature. The results obtained show that a significantly sharp electron temperature gradient is obtained with a typical gradient scale length of L T e ∼ 10   cm in the target plasma region. The outcome of this study may be useful both in plasma processing applications and for studying plasma turbulence in unmagnetized plasmas.

6 October 2026 in Fusion Engineering and Design
Verified
Journal Article
Closed access
AKAbha Kanik
Abha Kanik
BHBharat Hegde
Bharat Hegde
ASArun Sarma
Arun Sarma
SDSantosh Dubey
Santosh Dubey
LPLaxmikanta Pradhan
Laxmikanta Pradhan
KSK.P. Singh
K.P. Singh