The challenging and unstructured environment within pipelines demands the robotic exploration platforms with high adaptability, maneuverability, and recognition ability. Current soft robots equipped with cutting‐edge actuators have demonstrated inherent benefits in navigating pipeline environments due to their material compliance and morphological adaptability. However, achieving inner‐pipe detection for pipeline‐climbing robots challenges the integration of sensors without compromising the robot's flexibility and operational functionalities. Herein, a soft robot that locomotes within pipelines and performs exteroception is presented. The main body of the robot is fabricated based on origami designs, powered by pneumatic actuators for locomotion and incorporates triboelectric nanogenerators as tactile sensors (T‐TENGs). Physical experiments have demonstrated the soft robot's capacity in crawling in various pipeline conditions such as the horizontal, vertical, and curved configurations. The T‐TENG‐based sensory system outputs distinct voltage signals upon exposed to different material and structural conditions, for which a 1D‐convolutional neutral network algorithm is exposed to process with the sequential signals. The robot achieves an overall recognition accuracy of 99% for distinguishing between eight distinct pipe inner surface structures and four different types of materials.
Low-cost, high-performance hydrogen sensors are highly demanded in hydrogen leakage detection. To increase the sensitivity and reliability of the hydrogen sensor, an ionic liquid (IL)-based electrochemical gas sensor is fabricated with bimetallic Platinum–Nickel (Pt-Ni) nanoparticles (NPs) with aerosol jet printing technology for continuous monitoring of hydrogen concentration. The Pt-Ni NPs covering the top surface of the metal electrodes can accelerate the catalysis and expand the sensing surface area. When hydrogen gas is sensed at room temperature, the uniquely reversible and rapid redox reactions of hydrogen at the IL/Pt electrode interface, thereby creating continuous measurement capability in a real-time manner with little signal drift. The full coverage of the sensor electrodes will increase the robustness and accuracy of the device. The fabricated sensors demonstrate excellent analytical sensing performance, reaching a limit of detection up to 19.3 ppm. The device takes advantage of an easy fabrication process, simple structure, high sensing response, and low cost, providing a promise for hydrogen sensing at room temperatures.
6 September 2025 in International Journal of Heat and Mass Transfer