Sema Üzüm

Sema Üzüm

Auto-generated profile, based on publicly available information

Sema Üzüm

Department of Ophthalmology, Medical Faculty Hospital, Selcuk University, Konya, Turkey

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2024 in Turkish Journal of Ophthalmology
Verified
Journal Article
Open access
SÜSema Üzüm
Sema Üzüm
AOAyse Bozkurt Oflaz
Ayse Bozkurt Oflaz
SGSadagat Guluzade
Sadagat Guluzade
EKEmine Tınkır Kayıtmazbatır
Emine Tınkır Kayıtmazbatır
BBBanu Bozkurt
Banu Bozkurt
Ocular Involvement in Patients with Infantile Nephropathic Cystinosis - Turkish Journal of Ophthalmology

22 August 2025 in BMC Medical Education
Verified
Journal Article
Open access
PDF file
AOAyse Bozkurt Oflaz
Ayse Bozkurt Oflaz
GYGokce Yildiran
Gokce Yildiran
GCGülay Güler Canözer
Gülay Güler Canözer
SÜSema Üzüm
Sema Üzüm
EKEmine Tınkır Kayıtmazbatır
Emine Tınkır Kayıtmazbatır
SDSule Acar Duyan
Sule Acar Duyan
Simulation technologies have advanced surgical education by enhancing motor skills, hand-eye coordination, and sensory acuity. This study examines correlations between sensory-motor skills and surgical simulator performance. The cross-sectional and observational study included fifty medical doctors without surgical experience. Assessments included the McKinnon two-point discrimination test, the Semmes-Weinstein monofilament test, and the Nine-Hole Peg test. Performance scores for forceps, anti-tremor, and bimanual training modules were recorded using the Eyesi Surgical Simulator (VRmagic®, Mannheim, Germany). The mean age was 28.6 ± 4.4 years, with 28 females and 22 males. The mean value of McKinnon's two-point static discrimination test was 3.08 ± 0.72 mm, the Semmes-Weinstein Monofilament test was 2.42 ± 0.29 inches, and the Nine-Hole Peg Test mean completion time was 19.04 ± 2.60 seconds. Two-point discrimination test showed a significant negative correlation with bimanual training module scores within the 95% confidence interval (r =-0.41, p = 0.0027) but weak, non-significant correlations with forceps module (r = -0.23, p = 0.101) and anti-tremor modules (r = -0.10; p = 0.505). Monofilament test scores showed no significant correlations with simulator modules. The Nine-Hole Peg test correlated significantly with bimanual performance (r =-0.42, p = 0.002 and weakly with forceps scores (r =-0.24, p = 0.090). Simulation devices enhance surgical training by identifying sensory-motor deficits and adapting training. Motor skill and sensory acuity are associated with better bimanual performance and emphasize individualized approaches for optimal outcomes.