Background/Purpose: This study compared the effects of three induction doses of anti-vascular endothelial growth factor (anti-VEGF) on diabetic macular edema (DME) with that of long-term treatment using biomarkers to find out the predictability potential of early response to anti-VEGF treatment for the long-term restorative effect. Methods: We retrospectively reviewed the clinical and optical coherence tomography (OCT) data of 71 DME eyes treated with three monthly anti-VEGF doses and followed for 1 year. BCVA, central subfield thickness (CST), subretinal fluid (SRF), intraretinal cysts, hyperreflective foci (HF), disorganization of inner retinal layers (DRILs), ellipsoid zone/external limiting membrane (EZ/ELM) integrity, and vitreoretinal relationships were assessed at baseline, 3, 6, and 12 months. Results: Patients (50.7% male) had a mean follow-up of 12 months. After three anti-VEGF doses, 19 eyes required no additional injections, 25 continued anti-VEGF, 20 switched to dexamethasone implants, and seven received combination therapy. Best corrected visual acuity (BCVA) improved from 0.52 to 0.40 logMAR at 3 months, 0.30 at 6 months, and stabilized at 0.40 at 12 months. CST decreased from 406 µm to 317 µm at 3 months and 307 µm at 12 months. Significant early improvements in BCVA, CST, SRF, and intraretinal cysts were sustained in the long-term follow-up. HF reduction became significant after 6 months, while DRIL and EZ/ELM integrity remained unchanged. Conclusions: The improvement of OCT biomarkers in DME patients supported that intravitreal anti-VEGF significantly restored the retinal microstructure, which was already evident at 3 months in the control after anti-VEGF induction.
Background and Objectives: Children with autism spectrum disorder (ASD) often experience visual problems, yet their ophthalmic health remains underexplored due to testability challenges and limited-service access. This study evaluated ophthalmic screening outcomes in children with ASD and examined whether autism severity influenced ocular findings or cooperation during examinations. Materials and Methods: This cross-sectional study included 210 children with ASD (mean age 8.18 ± 4.99 years; 83.3% male). Examinations were conducted in an autism education center using non-contact methods: stereopsis (LANG I stereotest; LANG-STEREOTEST AG, Küsnacht, Switzerland), cover–uncover, and Hirschberg tests for strabismus, Spot Vision Screener (Welch Allyn Inc., Skaneateles Falls, NY, USA) for refractive errors, and Brückner test for red reflex. Autism severity was assessed with the Turkish version of the Adapted Autism Behavior Checklist (AABC). Results: Refractive errors were identified in 22.3% of participants: astigmatism in 15.2%, myopia in 5.2% (including 3 high myopia), and hyperopia in 1.9%. Strabismus was present in 11.9%, most commonly intermittent exotropia. Nearly half (49.5%) could not complete stereopsis testing, and a weak positive correlation was observed between AABC scores and the higher absolute spherical equivalent (SE) value between the two eyes (r = 0.173, p = 0.044). Children unable to complete stereopsis testing had significantly higher AABC scores (22.66 ± 9.69 vs. 13.39 ± 9.41, p < 0.001). Notably, 50 children (23.8%) had never undergone an eye examination prior to this study. Conclusions: Ophthalmic findings, particularly astigmatism and strabismus, are common in children with ASD. Greater autism severity was associated with reduced testability and modestly worse refractive error status. These findings suggest that tailored, accessible eye-care approaches and systematic vision screening may help to reduce overlooked visual problems and support more equitable care for children with ASD.
29 August 2025 in Ophthalmic and Physiological Optics
Background/ Aims: Sjögren’s syndrome (SS) and diabetes mellitus (DM) are common causes of dry eye disease (DED) and autologous serum is used when artificial tears are not sufficient. Our aim was to compare serum growth factor and inflammatory cytokine levels of SS and DM patients with the healthy individuals. Methods: Twenty-three SS patients (mean age 52.70±7.55 years), 25 DM patients (mean age 56.68±6.53 years), and 23 healthy subjects (mean age 51.70±9.14 years) were included in the study. After detailed ophthalmological examination, Schirmer test, tear break-up time (TBUT) and Ocular Surface Disease Index (OSDI) scores were measured. Serum levels of six different proinflammatory interleukins (IL), five growth factors, matrix metalloproteinase-9, and fibronectin were measured by immunoassay. One-way ANOVA or Kruskal-Wallis tests and Dunn-Bonferroni post hoc analysis were used for comparison and p<0.05 was considered significant. Results: Schirmer test and TBUT were significantly lower in the SS group (2.08±1.72 mm/5 min and 3.08±2.08 s) than in the DR (10.24±4.63 mm/5 min and 4.20±3.09 s) and control groups (13.30±5.95 mm/5 min and 9.00±1.75 s) (p<0.001). Among the parameters studied, mean serum IL-23 level was significantly higher in the SS group (156.66±207.94 pg/mL) than in the DM and control groups (73.48±95.91 and 69.59±105.39 pg/mL, respectively) (p<0.05). Serum insulin-like growth factor 1 (IGF-1) level was lowest in DM patients (DM: 12.89±21.09, SS: 30.77±19.85, and control: 27.08±21.93 ng/mL) (p<0.05). Sjögren’s syndrome disease activity index (ESSDAI) showed a negative correlation with TBUT and a positive correlation with IL-1, IL-2 and fibronectin (p<0.005). Conclusions: Except IL-23 and IGF-1, the contents of serum obtained from patients with SS and DM are similar with the healthy individuals. Therefore, autologous serum seems to be a good option to replace deficient tear fluid in these subjects.
Stem cells have been used for therapeutic purposes in many areas of medicine for many years. Depending on the tissues from which they are derived and their characteristics, stem cells can be classified into various groups. Some types of stem cells have the capacity to form an entire organism, while others can only differentiate into certain groups of tissues. In recent years, stem cells have also become popular in ophthalmology. Both stem cells found in ocular tissues and those derived from peripheral tissues are gaining attention for their use in ophthalmology. In ophthalmology, stem cells have a wide range of applications, from ocular surface and periocular tissue applications to retinal diseases. Some applications, such as limbal stem cell transplantation, have become common practices in clinical settings, while experimental and promising stem cell methods, such as anterior chamber stem cell transplants or subretinal supracoroidal stem cell transplants, are being investigated. Stem cells offer hope in ophthalmology for diseases that are unresponsive to traditional treatments, irreversible diseases, or dystrophic diseases that still lack approved treatments. The long-term effects of stem cell transplants in ophthalmology have not been clearly established, and the potential for tumor development due to uncontrolled proliferation has not been entirely eliminated. While there is a possibility of negative results from experimental studies and the emergence of concerning side effects, stem cells still hold promise as an alternative treatment option in ophthalmology.
Simulation technologies have advanced surgical education by enhancing motor skills, hand-eye coordination, and sensory acuity. This study examines correlations between sensory-motor skills and surgical simulator performance. The cross-sectional and observational study included fifty medical doctors without surgical experience. Assessments included the McKinnon two-point discrimination test, the Semmes-Weinstein monofilament test, and the Nine-Hole Peg test. Performance scores for forceps, anti-tremor, and bimanual training modules were recorded using the Eyesi Surgical Simulator (VRmagic®, Mannheim, Germany). The mean age was 28.6 ± 4.4 years, with 28 females and 22 males. The mean value of McKinnon's two-point static discrimination test was 3.08 ± 0.72 mm, the Semmes-Weinstein Monofilament test was 2.42 ± 0.29 inches, and the Nine-Hole Peg Test mean completion time was 19.04 ± 2.60 seconds. Two-point discrimination test showed a significant negative correlation with bimanual training module scores within the 95% confidence interval (r =-0.41, p = 0.0027) but weak, non-significant correlations with forceps module (r = -0.23, p = 0.101) and anti-tremor modules (r = -0.10; p = 0.505). Monofilament test scores showed no significant correlations with simulator modules. The Nine-Hole Peg test correlated significantly with bimanual performance (r =-0.42, p = 0.002 and weakly with forceps scores (r =-0.24, p = 0.090). Simulation devices enhance surgical training by identifying sensory-motor deficits and adapting training. Motor skill and sensory acuity are associated with better bimanual performance and emphasize individualized approaches for optimal outcomes.