31 March 2021 in IEEE Transactions on Haptics
Through nonlinear effects, airborne ultrasound phased arrays enable mid-air tactile presentations, as well as auditory presentation and acoustic levitation. To create workplaces flexibly, we have developed a scalable phased array system in which multiple modules can be connected via Ethernet cables and controlled from a PC or other host device. Each module has 249 transducers and the software used can individually specify the phase and amplitude of each of the connected transducers. Using EtherCAT for communication, the system achieves high accuracy synchronization among the connected modules. In this article, we describe the details of the hardware and software architecture of the developed system and evaluate it. We experimentally confirmed the synchronization of 20 modules within an accuracy of $0.1~\mathrm{{\mu }s}$ and the phase and amplitude can be specified at $8~\mathrm{bits}$ resolution. In addition, using nine modules, we confirmed that we could make a focal point of the size consistent with the theory at $500~\mathrm{mm}$ above the array surface.
15 January 2020 in IEEE Transactions on Haptics
Ultrasound emitted from an array of transducers can produce various tactile sensations by temporally controlling the phase and amplitude of the transducers. However, the controllability in haptic applications has not been well examined. This study clarifies a phase shift of the driving signal causes amplitude fluctuation of emitted ultrasound, even under a constant driving amplitude. We demonstrate theoretically that this problem exists in general resonant systems with various quality factors, and point out that it produces radiation force decrease and audible noise. We also show a method to reduce the fluctuation and quantitatively evaluate the effectiveness. The results provide the measure of the displayed force fluctuation by a fast focus movement and enable silent haptic stimulation.
8 November 2021 in IEEE Transactions on Haptics
Focused airborne ultrasound provides various noncontact spatiotemporal pressure patterns on the skin. However, the presentation of static force remains an untouched issue because the static radiation force by ultrasound is too weak for the human hand to perceive. Hence, creatable sensations have been limited to vibrations or some dynamically changing feelings. This study demonstrates that a non-vibratory pressure sensation is presented by low-frequency Lateral Modulation (LM) with a fine spatial step width. LM is a pressure modulation method that moves a single ultrasound focus laterally and repetitively along the skin surface. The produced sensation in this study was not perfectly static, but the vibratory perception contained in the stimulus was significantly suppressed under a condition while maintaining its intense perception. We found the condition was 5 to 15 Hz in the LM frequency with a motion step width of less than 1 mm. In a comparison test in the most vibration-suppressed case, the participants reported 0.21 N as an equivalent force to the LM stimulus, significantly higher than the 0.027 N force physically applied by the ultrasound. The statistical analysis also showed that the step width of the LM had a significant effect on its vibratory sensation but not on the intensity of the evoked pressure sensation.
19 October 2022 in Physical Review Applied
Recently, the applications of airborne ultrasound technology have garnered considerable attention; however, high-speed ultrasound field measurements in air have not been well researched. This study demonstrates that thermal responses to high-intensity airborne ultrasound can be used to visualize airborne ultrasound fields. Thermal images on a mesh screen enable the rapid quantitative measurement of two-dimensional ultrasound fields. Additionally, based on the temperature distribution on a surface that reflects ultrasound waves, it is possible to determine the ultrasound focus position with a resolution much finer than the wavelength. The results demonstrate that thermography observations based on ultrasound-temperature conversion, which are conventionally time-consuming or difficult to perform, can be used to visualize acoustic fields within 0.5 s. These findings will advance engineering applications that use strong airborne ultrasound, such as midair haptics and acoustic levitation, and provide scientific and technical applications for detecting surface properties and composition, including those of cells and fragile materials.
30 March 2006 in Physical Review A
TCTRIUMF Muonic Hydrogen Collaboration
TRIUMF Muonic Hydrogen Collaboration
+16
We present the final results of an experimental study of and atom scattering in solid hydrogen cooled to . Strong effects resulting from the Ramsauer-Townsend effect have been observed in the TRIUMF experiment E742 where muons were stopped in thin frozen layers of hydrogen. The measured Ramsauer-Townsend minimum energy for both and atoms and the minimum cross section are in agreement with theory.
29 April 2021 in IEEE Transactions on Haptics
Non-contact tactile presentation using ultrasound phased arrays is becoming a powerful method for providing haptic feedback on bare skin without restricting the user's movement. In such ultrasonic mid-air haptics, it is often necessary to generate multiple ultrasonic foci simultaneously, which requires solving the inverse problem of amplitudes and phases of the transducers in a phased array. Conventionally, matrix calculation methods have been used to solve this inverse problem. However, a matrix calculation requires a non-negligible amount of time when the number of control points and the number of transducers in the array are large. In this article, we propose a simple method based on a greedy algorithm and brute-force search to solve the field reconstruction problem. The proposed method directly optimizes the desired field without matrix calculation or target field phase optimization. The empirical results indicate that the proposed method can reproduce the target sound with an accuracy of more than 80%.