Focused airborne ultrasound provides various noncontact spatiotemporal pressure patterns on the skin. However, the presentation of static force remains an untouched issue because the static radiation force by ultrasound is too weak for the human hand to perceive. Hence, creatable sensations have been limited to vibrations or some dynamically changing feelings. This study demonstrates that a non-vibratory pressure sensation is presented by low-frequency Lateral Modulation (LM) with a fine spatial step width. LM is a pressure modulation method that moves a single ultrasound focus laterally and repetitively along the skin surface. The produced sensation in this study was not perfectly static, but the vibratory perception contained in the stimulus was significantly suppressed under a condition while maintaining its intense perception. We found the condition was 5 to 15 Hz in the LM frequency with a motion step width of less than 1 mm. In a comparison test in the most vibration-suppressed case, the participants reported 0.21 N as an equivalent force to the LM stimulus, significantly higher than the 0.027 N force physically applied by the ultrasound. The statistical analysis also showed that the step width of the LM had a significant effect on its vibratory sensation but not on the intensity of the evoked pressure sensation.
Recently, the applications of airborne ultrasound technology have garnered considerable attention; however, high-speed ultrasound field measurements in air have not been well researched. This study demonstrates that thermal responses to high-intensity airborne ultrasound can be used to visualize airborne ultrasound fields. Thermal images on a mesh screen enable the rapid quantitative measurement of two-dimensional ultrasound fields. Additionally, based on the temperature distribution on a surface that reflects ultrasound waves, it is possible to determine the ultrasound focus position with a resolution much finer than the wavelength. The results demonstrate that thermography observations based on ultrasound-temperature conversion, which are conventionally time-consuming or difficult to perform, can be used to visualize acoustic fields within 0.5 s. These findings will advance engineering applications that use strong airborne ultrasound, such as midair haptics and acoustic levitation, and provide scientific and technical applications for detecting surface properties and composition, including those of cells and fragile materials.
A noncontact tactile stimulus can be presented by focusing airborne ultrasound on the human skin. Focused ultrasound has recently been reported to produce not only vibration but also static pressure sensation on the palm by modulating the sound pressure distribution at a low frequency. This finding expands the potential for tactile rendering in ultrasound haptics as static pressure sensation is perceived with a high spatial resolution. In this study, we verified that focused ultrasound can render a static pressure sensation associated with contact with a small convex surface on a finger pad. This static contact rendering enables noncontact tactile reproduction of a fine uneven surface using ultrasound. In the experiments, four ultrasound foci were simultaneously and circularly rotated on a finger pad at 5 Hz. When the orbit radius was 3 mm, vibration and focal movements were barely perceptible, and the stimulus was perceived as static pressure. Moreover, under the condition, the pressure sensation rendered a contact with a small convex surface with a radius of 2 mm. The perceived intensity of the static contact sensation was equivalent to a physical contact force of 0.24 N on average, 10.9 times the radiation force physically applied to the skin.
Adding tactile feedback to a midair image realizes immersive mixed reality contents. In this study, we develop a midair 3D image with a noncontact cooling sensation using ultrasound. In this system, users can feel a cooling sensation when touching the 3D image with their bare hands. The noncontact cooling sensation is rapidly displayed by ultrasound-driven mist vaporization. In the previous ultrasound haptic-optic display, only mechanical tactile feedback e.g. vibration has been used. The cooling sensation can extend the displayable material texture of the ultrasound haptic system. In the demo, we present a 3D image of ice. Participants can touch the image freely and feel its realistic cooling sensation.
Phantom Sensation (PhS) is a tactile illusion in which a single sensation is elicited by stimulating two distant points. That sensation moves continuously between the two stimuli by changing the amplitude ratio. In this paper, we compared PhS for two types of tactile stimuli: lateral modulation (LM) of 20 Hz and amplitude modulation (AM) of 200 Hz. In LM, a stimulus point is moved periodically and laterally by several millimeters. In AM, the pressure is changed periodically at a fixed stimulation point. LM and AM are produced by ultrasound radiation pressure, where the force intensity of LM and AM were changed with the same temporal pattern. The results showed that the continuity and the localization of PhS elicited by LM at 20 Hz were significantly smaller than those elicited by AM at 200 Hz in 18 out of 24 conditions. However, PhS remained in all conditions that we used, regardless of LM or AM, even for an extremely long duration of 7.5 s and a short duration of 0.5 s.
A lightweight haptic display that does not interfere with the user's natural movement is required for an immersive haptic experience. This study proposes a lightweight, powerful, and responsive passive haptic actuator driven by airborne focused ultrasound. This 6.2 g completely plastic passive device amplifies an applied ultrasound radiation force by a factor of 35 using a simple lever mechanism, presenting an amplified force of 0.7 N to the user's finger pad. 2-30 Hz vibration can also be presented. Since the radiation force is presented at the speed of sound, the amplified force is presented at high speed even with the high amplification rate of a lever, achieving such strong force and vibration presentation. Physical measurements showed that the amplified force was 0.7 N for the 20 mN input radiation force, and the amplitude of the presented vibration was over 0.1 N at 2-30 Hz. A psychophysical experiment showed that the vibration and force were perceivable with a device output level of -7.7 dB. In the future, we will explore methodologies around device design to present desired tactile sensations.