Davide Ceresa

Davide Ceresa

Auto-generated profile, based on publicly available information

Davide Ceresa

CERN, Esplanade des Particules 1, 1211 Geneva, Switzerland

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2025 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
GBGiulio Borghello
Giulio Borghello
GTGennaro Termo
Gennaro Termo
FFFederico Faccio
Federico Faccio
DCDavide Ceresa
Davide Ceresa
RPRisto Pejašinović
Risto Pejašinović
KKKostas Kloukinas
Kostas Kloukinas
Evidence of Enhanced Low-Dose-Rate Sensitivity (ELDRS) in TID-induced leakage current increase was observed in ring-oscillators and SRAMs in 28nm CMOS technology exposed to ultra-high doses. Elevated temperature irradiation on isolated devices is used to evaluate the dependence of ELDRS on bias conditions, device size, and threshold voltage. The results obtained show that irradiation at high temperature can represent reasonably well ELDRS, providing a viable solution for accelerated radiation tests.

7 March 2026 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
RBR. Ballabriga
R. Ballabriga
FBF. Bandi
F. Bandi
GBG. Bergamin
G. Bergamin
WBW. Bialas
W. Bialas
MCM. Campbell
M. Campbell
KWK. Wyllie
K. Wyllie

1 March 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
GBG. Bergamin
G. Bergamin
DCD. Ceresa
D. Ceresa
DCDuje Coko
Duje Coko
GCG. Cummings
G. Cummings
VGV. Gingu
V. Gingu
JYJ. Ye
J. Ye
With over 6 million channels, the High Granularity Calorimeter (HGCAL) for the CMS HL-LHC Upgrade presents a unique data challenge. The ECON ASICs provide critical on-detector data reduction for the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are rad-tolerant (600 Mrad) with low power consumption (<2.5 mW/channel). This presentation is the first comprehensive description of the ECON designs, first functionality and radiation tests for the ECON-T ASIC, and first results from the full production of 75k ECON-D and ECON-T ASICs.


1 February 2025 in Journal of Instrumentation
Verified
Journal Article
Open access
MLM. Lupi
M. Lupi
GBG. Bergamin
G. Bergamin
DCD. Ceresa
D. Ceresa
DCDuje Coko
Duje Coko
GCG. Cummings
G. Cummings
TCthe CMS collaboration
the CMS collaboration
The High-Granularity Calorimeter (HGCAL) will replace the current CMS Endcap Calorimeter during Long-Shutdown 3. The Endcap Concentrator (ECON) ASICs represent key elements in the readout chain, processing trigger (ECON-T) and data (ECON-D) streams from the HGCROC to the lpGBT. The ECONs will operate in a radiation environment with a High-Energy Hadron (E≥20 MeV) flux up to 2·107 cm-2s-1. This contribution describes the Universal Verification Methodology (UVM)-based functional verification of the ECON ASICs focusing on the re-use of existing components to manage the complexity of the verification environment.

1 March 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
MLM. Lupi
M. Lupi
RBRafael Ballabriga
Rafael Ballabriga
FBF.N. Bandi
F.N. Bandi
GBG. Bergamin
G. Bergamin
DCD. Ceresa
D. Ceresa
KWK. Wyllie
K. Wyllie
The FastRICH ASIC provides high-precision, triggerless readout for the LS3 Enhancements and Upgrades II of the LHCb RICH detector. The demands of continuous data acquisition and varying hit rates across the detector impose unique challenges on the ASIC's design and verification. This work presents the verification strategy for FastRICH, focusing on functional correctness, timing performance, and operational robustness. The methodology includes simulations across occupancy scenarios, validation of timing precision, and stress testing under pile-up and high-rate conditions. Results demonstrate that FastRICH meets its performance requirements over the full range of expected occupancies. Key design and verification challenges specific to triggerless, fast-timing ASICs are discussed, along with lessons learned for future developments.