17 January 2019 in American Journal of Neuroradiology
SUMMARY: Magnetic particle imaging is an emerging tomographic technique with the potential for simultaneous high-resolution, high-sensitivity, and real-time imaging. Magnetic particle imaging is based on the unique behavior of superparamagnetic iron oxide nanoparticles modeled by the Langevin theory, with the ability to track and quantify nanoparticle concentrations without tissue background noise. It is a promising new imaging technique for multiple applications, including vascular and perfusion imaging, oncology imaging, cell tracking, inflammation imaging, and trauma imaging. In particular, many neuroimaging applications may be enabled and enhanced with magnetic particle imaging. In this review, we will provide an overview of magnetic particle imaging principles and implementation, current applications, promising neuroimaging applications, and practical considerations.
1 September 2012 in Radiology
The macrophage tracking technique presented could reveal differential macrophage accumulation in viable versus apoptotic matrix-associated stem cell implants and could potentially also be applied f... PurposeTo develop a clinically applicable imaging technique for monitoring differential migration of macrophages into viable and apoptotic matrix-associated stem cell implants (MASIs) in arthritic ...
1 February 2025 in Arteriosclerosis, Thrombosis, and Vascular Biology
BACKGROUND: Computational modeling indicated that pathological high shear stress (HSS; 100 dyn/cm 2 ) is generated in pulmonary arteries (PAs; 100–500 µm) in congenital heart defects causing PA hypertension (PAH) and in idiopathic PAH with occlusive vascular remodeling. Endothelial-to-mesenchymal transition (EndMT) is a feature of PAH. We hypothesize that HSS induces EndMT, contributing to the initiation and progression of PAH. METHODS: We used the Ibidi perfusion system to determine whether HSS applied to human PA endothelial cells (ECs) induces EndMT when compared with physiological laminar shear stress (15 dyn/cm 2 ). The mechanism was investigated and targeted to prevent PAH in a mouse with HSS induced by an aortocaval shunt. RESULTS: EndMT, a feature of PAH not previously attributed to HSS, was observed. HSS did not alter the induction of transcription factors KLF (Krüppel-like factor) 2/4, but an ERG (ETS-family transcription factor) was reduced, as were histone H3 lysine 27 acetylation enhancer-promoter peaks containing ERG motifs. Consequently, there was reduced interaction between ERG and KLF2/4, a feature important in tethering KLF and the chromatin remodeling complex to DNA. In PA ECs under laminar shear stress, reducing ERG by siRNA caused EndMT associated with decreased BMPR2 (bone morphogenetic protein receptor 2), CDH5 (cadherin 5), and PECAM1 (platelet and EC adhesion molecule 1) and increased SNAI1/2 (Snail/Slug) and ACTA2 (smooth muscle α2 actin). In PA ECs under HSS, transfection of ERG prevented EndMT. HSS was then induced in mice by an aortocaval shunt, causing progressive PAH over 8 weeks. An adeno-associated viral vector (AAV2-ESGHGYF) was used to replenish ERG selectively in PA ECs. Elevated PA pressure, EndMT, and vascular remodeling (muscularization of peripheral arteries) in the aortocaval shunt mice were markedly reduced by ERG delivery. CONCLUSIONS: Pathological HSS reduced lung EC ERG, resulting in EndMT and PAH. Agents that upregulate ERG could reverse HSS-mediated PAH and occlusive vascular remodeling resulting from high flow or narrowed PAs.
29 March 2010 in Magnetic Resonance in Medicine
Multiecho echo‐planar imaging (EPI) was implemented for blood‐oxygenation‐level‐dependent functional MRI at 1.5 T and compared to single‐echo EPI with and without parallel imaging acceleration. A time‐normalized breath‐hold task using a block design functional MRI protocol was carried out in combination with up to four echo trains per excitation and parallel imaging acceleration factors R = 1–3. Experiments were conducted in five human subjects, each scanned in three sessions. Across all reduction factors, both signal‐to‐fluctuation‐noise ratio and the total number of activated voxels were significantly lower using a single‐echo EPI pulse sequence compared with the multiecho approach. Signal‐to‐fluctuation‐noise ratio and total number of activated voxels were also considerably reduced for nonaccelerated conventional single‐echo EPI when compared to three‐echo measurements with R = 2. Parallel imaging accelerated multiecho EPI reduced geometric distortions and signal dropout, while it increased blood‐oxygenation‐level‐dependent signal sensitivity all over the brain, particularly in regions with short underlying T *2. Thus, the presented method showed multiple advantages over conventional single‐echo EPI for standard blood‐oxygenation‐level‐dependent functional MRI experiments. Magn Reson Med 63:959–969, 2010.
19 March 2025 in Nanoscale
Magnetic resonance imaging and two-photon intravital microscopy metrics were correlated to track Ferumoxytol-based theranostic nanoparticles targeting glioblastoma multiforme in vivo at both macroscopic and microscopic levels.
1 October 2016 in Natural Product Communications
This paper describes the enantioselective synthesis of analogues of sapinofuranones A and B, namely 5-substitutes dihydro- and 5 H-furan-ones, and their in vitro growth inhibitory activity against six cancer cell lines in comparison with fungal furanones such as diplofuranone A, diplobifuranylones A and B, as well as ( S,S)-enantiomer of sapinofuranone B. The compounds under study displayed weak if any in vitro growth inhibitory activity against the analysed cancer cell lines. However, it seems that among dihydro- and 5 H-furan-ones bearing a 1-hydroxypentyl side chain, the stereochemistry of the furanone ring and that of hydroxylated methine could modify the in vitro growth activity of these compounds. The natural furanones that showed a different unsaturated chain at C-4 or rearranged into a dihydrofuran ring appeared to be inactive in terms of growth inhibitory activity, e.g. displaying growth inhibitory concentration at 50% (GI50) > 100 μM in all six cancer cell lines analysed.