This article is devoted to demonstrate the feasibility of laser cutting technique for the fuel debris retrieval into the Fukushima Daiichi damaged reactors. IRSN is involved in a project led by ONET Technologies, in collaboration with CEA, to evaluate the risk occurred by the dispersion of aerosols emitted by the dismantling operations [4]. During the laser cutting operations of fuel debris in air condition, particles will be produced, inducing a potential risk of dispersion into the environment. Hence, evaluating the fate of these particles after their emission is one of the safety key issues for these dismantling operations. In this objective, IRSN performed CFD simulations of dispersion of particles representative of inactive fuel debris simulants (1)(2)(3)(4). The first numerical results (5) showed a quite good agreement but some improvements were needed to take into account complex particle size distributions (PSD). Consequently, this article proposes an alternative method to better initialize the agglomeration calculation, in order to take account for different kinds of particle size distribution in the CFD simulations and to better evaluate the fate of aerosols produced by the debris cutting in the damaged reactors of Fukushima-Daiichi pedestal.
The general context of this paper is an evaluation of strategies that can be used to mitigate aerosol dispersion during fuel debris or corium retrieval in damaged Fukushima Daiichi reactors. Knowledge of the aerosol source terms released during fuel debris retrieval operations is one of the key factors for assessing aerosol dispersion leading to the potential dissemination of radionuclides into the environment. Our approach is to couple experimental results from integral tests obtained during laser cutting experiments, well-controlled analytical tests with separated effects performed in a dedicated facility to reproduce two-phase flow such as flows representative of pool scrubbing and spray scrubbing conditions, and numerical simulations. Integral tests provide relevant information on the airborne particle release fraction during laser cutting for underwater conditions at different water depths, such as the particle concentration and particle size distribution. However, the detailed characterization of two-phase flows, such as the size and velocity of gas bubble and water droplets generated by spray systems, is not possible during laser cutting integral tests. Therefore, a more analytical approach is necessary to obtain detailed information on two-phase flow, composed of bubbles in water, inducing pool scrubbing phenomenon, and droplets in gas generated by spray scrubbing systems used for mitigating dust dispersion, which are essential to the physical mechanisms of both processes and enable their respective efficiencies to be evaluated. The main objectives of this work were to develop models and ensure their validation based on experimental approach for predicting the pool scrubbing and spray scrubbing efficiencies in the context of fuel debris removal at Fukushima Daiichi.