15 April 2021 in IEEE Transactions on Power Electronics
Nowadays, neutral point voltage (NPV) balancing control and leakage current (LC) reduction methods are considered to improve the reliability of transformerless three-level T-type (3LT 2 ) inverter. Medium vector pulse width modulation (MVPWM) method can control the inverter operation to eliminate the LC; however, is powerless to balance the NPV. Alternatively, discontinuous PWM (DPWM) methods can be implemented to balance the NPV. In this article, a hybrid method for transformerless 3LT 2 inverter is proposed to simultaneously minimize the LC and accomplish balancing control in case of NPV unbalancing. The proposed method applies MVPWM switching patterns to eliminate LC while the NPV is balanced. If the NPV becomes unbalanced, it applies specific switching patterns of the DPWM methods as alternative patterns to balance the NPV with minimal LC. Accordingly, the proposed method not only maintains the LC elimination advantage of the MVPWM method but also realizes the NPV balancing capability without any topology modification or adding electrical components. Noteworthy, even the NPV balancing is accomplished with minimal flow of the LC. The proposed method is carrier-based PWM, which shortens execution time and simplifies practical implementation. Experimental tests have been accomplished and results demonstrate the effectiveness of the proposed method on adding the NPV balancing capability with minimal LC to the MVPWM method.
23 August 2022 in IEEE Transactions on Industry Applications
Nowadays, the three-level T-type inverters (3LT2Is) are widely employed in applications with high-performance requirements. The 3LT2Is commonly suffer from neutral point voltage (NPV) unbalance and common-mode voltage (CMV) variation. The medium vector pulse width modulation (MVPWM), which generates the reference voltage using medium and V0[OOO] zero voltage vectors, eliminates the CMV variation in 3LT2Is. However, it cannot keep the NPV balance, negatively affecting power quality. This paper proposes a hybrid method to simultaneously eliminate CMV variation and guarantee the NPV balance without topological change or extra hardware. The proposed method uses MVPWM when NPV is balanced, eliminating CMV variation. If NPV goes unbalanced, it utilizes novel high/low triangle PWM (H/LPWM) and MVPWM in a hybrid manner to balance the NPV. The H/LPWM, similar to MVPWM, synthesizes voltage using medium and V0[OOO] voltage vectors to maintain the CMV elimination advantage during the NPV balancing process. However, the difference between H/LPWMs and MVPWM switching patterns adjusts the average neutral point current to balance the NPV. Noteworthy that the proposed method provides NPV balancing ability for the entire power factor range. As a result, it is usable for various applications of 3LT2I, such as photovoltaic inverters, motor drives, etc. The proposed method is carrier-based which reduces the execution time and simplifies the practical implementation. The simulation study and experimental evaluation have been accomplished, and their results demonstrate the effectiveness of the proposed method.
14 October 2024 in Electric Power Systems Research
29 October 2021 in IEEE Access
Nowadays, photovoltaic (PV) systems based on centralized topology with a three-level T-type (3LT 2 ) inverter are used to decrease investment costs and increase conversion efficiency. In this topology, the split capacitors of the DC-link can individually connected to PV arrays. Accordingly, DC-link capacitors’ voltage should separately controlled to track PV arrays’ maximum power point (MPP) voltage. However, the asymmetric control of capacitors’ voltage causes line voltage to unbalance and output current to distort. In this paper, a hybrid method based on dipolar variable injection and zero-sequence voltage injection concepts is proposed to simultaneously control the DC-link capacitors’ voltage of the 3LT 2 inverter and eliminate their voltages ripple. In the presence of partial shading, the proposed method can control the capacitors’ voltage of the DC-link to realize the separate MPP tracking while ensuring the balance of line voltages. Furthermore, the proposed method eliminates the voltage ripple on DC-link capacitors, inherently caused by the 3LT 2 inverter, to improve the DC-link lifetime and the PV system reliability. The simulation studies and practical experiments have been performed, and their results prove the validity of the proposed method, whether the PF is unity or non-unity.
12 November 2024 in IEEE Transactions on Industrial Electronics
Single-line ground (SLG) faults are the most common faults in distribution networks. Cascaded H-bridge multilevel converters (CHMCs) can be employed to suppress fault current and potential and prevent hazards promptly. However, their application is limited by their high cost and large size. This article proposes a cost- and size-efficient implementation method of single-phase CHMC for fault suppression, performed by minimizing the required dc sources. In this method, the output voltage vector of CHMC is reconstructed during fault elimination by two mutually perpendicular subvoltage vectors, one perpendicular and the other parallel to the target output current vector of CHMC. The subvoltage parallel to the target output current, which provides all required active power output, is generated using an H-bridge cell supplied by a dc source with minimized capacity. The remaining H-bridge cells generate the subvoltage perpendicular to the target output current without any dc source employment since they are solely responsible for reactive power output, thus maintaining their dc capacitor voltages. The simulation study and experimental validation have been conducted, and the results demonstrate that not only is the proposed method cost- and size-effective but also effectively ensures SLG fault elimination.