Jaime E. Lara

Jaime E. Lara

Auto-generated profile, based on publicly available information

Jaime E. Lara

Auckland Bioengineering Institute, The University of Auckland, New Zealand

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
JLJaime E. Lara
Jaime E. Lara
LCLeo Cheng
Leo Cheng
OROliver Rohrle
Oliver Rohrle
NPNiranchan Paskaranandavadivel
Niranchan Paskaranandavadivel
Objective: Dexterous hand motion is critical for object manipulation. Electrophysiological studies of the hand are key to understanding its underlying mechanisms. High-density electromyography (HD-EMG) provides spatio-temporal information about the underlying electrical activity of muscles, which can be used in neurophysiological research, rehabilitation and control applications. However, existing EMG electrodes platforms are not muscle-specific, which makes the assessment of intrinsic hand muscles difficult. Methods: Muscle-specific flexible HD-EMG electrode arrays were developed to capture intrinsic hand muscle myoelectric activity during manipulation tasks. The arrays consist of 60 individual electrodes targeting 10 intrinsic hand muscles. Myoelectric activity was displayed as spatio-temporal amplitude maps to visualize muscle activation. Time-domain and temporal-spatial HD-EMG features were extracted to train cubic support vector machine machine-learning classifiers to classify the intended user motion. Results: Experimental data was collected from 5 subjects performing a range of 10 common hand motions. Spatio-temporal EMG maps showed distinct activation areas correlated to the muscles recruited during each movement. The thenar muscle fiber conduction velocity (CV) was estimated to be at 4.7±0.3 m/s for all subjects. Hand motions were successfully classified and average accuracy for all subjects was directly related to spatial resolution based on the number of channels used as inputs; ranging from 74±4% when using only 5 channels and up to 92±2% when using 41 channels. Temporal-spatial features were shown to provide increased motion-specific accuracy when similar muscles were recruited for different gestures. Conclusions: Muscle-specific electrodes were capable of accurately recording HD-EMG signals from intrinsic hand muscles and accurately predicting motion. Significance: The muscle-specific electrode arrays could improve electrophysiological research studies using EMG decomposition techniques to assess motor unit activity and in applications involving the analysis of dexterous hand motions.

1 October 2015
Verified
Conference Paper
Closed access
JLJaime E. Lara
Jaime E. Lara
AVArturo Vera-Hernández
Arturo Vera-Hernández
LLLorenzo Leija
Lorenzo Leija
MGMario Ibrahin Gutierrez
Mario Ibrahin Gutierrez
Liver tumors can be treated by microwave ablation, a therapy in which the goal is to increase the tissue's temperature in order to induce necrosis. For the application of microwave ablation interstitial antenna applicators have been developed with the objective of delivering and focusing energy deposition on the tissue in an effective manner. Choked antennas propose an ideal solution, as they are capable of producing a punctual hot-spot that prevents backward heating of the antenna. In this work designs for a choked and un-choked metal-tip monopole antenna are presented and modeled using finite element method to obtain their heating patterns, power deposition and temperature distributions, compare them and analyze the effects of the metallic choke over the same base antenna design at a frequency of 2.45 GHz and a power of 10 W.

1 April 2016
Verified
Conference Paper
Closed access
JLJ. E. Lara
J. E. Lara
AVArturo Vera-Hernández
Arturo Vera-Hernández
LLLorenzo Leija
Lorenzo Leija
In this paper a series of designs of micro coaxial antennas for MWA therapy to be used for the treatment of breast cancer tumors coupled to both breast and tumoral tissue is presented. The designs were modeled and optimized using Finite Element Method (FEM) simulation to ensure the minimal SWR possible value and obtain several parameters of interest such as the antenna's radiation patterns, temperature distributions and estimated lesion sizes.

24 November 2016
Verified
Conference Paper
Closed access
AMAdriana Manzanarez
Adriana Manzanarez
JLJaime E. Lara
Jaime E. Lara
AVArturo Vera-Hernández
Arturo Vera-Hernández
LLLorenzo Leija
Lorenzo Leija
MGMario Ibrahin Gutierrez
Mario Ibrahin Gutierrez
This paper presents a model of microwave radiation into the surrounding tissues in the therapy of ablation of breast using the finite element method (FEM). Three designs of antennas with different diameters have been proposed to carry out simulations with the surrounding tissues: adipose tissue, connective and glandular tissue and tumor tissue. The tissues of the breast should be considered in the study of the effectiveness of the antennas to observe the change of patterns of the Specific Absortion Rate (SAR). The FEM provides information for designing of microcoaxial antennas and its effects. The antennas of 0.95 and 1.3 mm of diameter have a Standing Wave Ratio (SWR) lower than the antenna with a diameter of 2.30 mm, so the smaller diameter antennas have a better response to a depth of 50 mm with a SWR of 1.5.

1 July 2019
Verified
Conference Paper
Closed access
JLJ. Lara
J. Lara
NPNiranchan Paskaranandavadivel
Niranchan Paskaranandavadivel
LCLeo Cheng
Leo Cheng
Electromyography (EMG) based control systems rely on the accurate identification of patterns extracted from signal features to predict the corresponding movement. The selection of segmentation window parameters and their impact on overall accuracy of classifiers has been previously studied for systems with a low number of EMG channels (<16). In this study a High-density EMG electrode array was used to evaluate the impact of the parameters when a high number of channels (128) was recorded. Findings show that in combination with high channel counts the impact of window length and overlap were marginal (<2% and <1% respectively). The number of channels was found to have direct correlation with achieved accuracy, with an improvement of up to 19.5 ± 4.5% in classification accuracy when increasing from 4 to 128 channels.