Mingjian Hong

Mingjian Hong

Auto-generated profile, based on publicly available information

Mingjian Hong

Chongqing University

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2011 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
MHMingjian Hong
Mingjian Hong
YYYeyang Yu
Yeyang Yu
HWHua Wang
Hua Wang
FLFeng Liu
Feng Liu
SCStuart Crozier
Stuart Crozier
Compressed sensing MRI (CS-MRI) aims to significantly reduce the measurements required for image reconstruction in order to accelerate the overall imaging speed. The sparsity of the MR images in transformation bases is one of the fundamental criteria for CS-MRI performance. Sparser representations can require fewer samples necessary for a successful reconstruction or achieve better reconstruction quality with a given number of samples. Generally, there are two kinds of 'sparsifying' transforms: predefined transforms and data-adaptive transforms. The predefined transforms, such as the discrete cosine transform, discrete wavelet transform and identity transform have usually been used to provide sufficiently sparse representations for limited types of MR images, in view of their isolation to the object images. In this paper, we present singular value decomposition (SVD) as the data-adaptive 'sparsity' basis, which can sparsify a broader range of MR images and perform effective image reconstruction. The performance of this method was evaluated for MR images with varying content (for example, brain images, angiograms, etc), in terms of image quality, reconstruction time, sparsity and data fidelity. Comparison with other commonly used sparsifying transforms shows that the proposed method can significantly accelerate the reconstruction process and still achieve better image quality, providing a simple and effective alternative solution in the CS-MRI framework.

22 August 2019 in Journal of Chemometrics
Verified
Journal Article
Closed access
PDF file
JDJialin Dong
Jialin Dong
MHMingjian Hong
Mingjian Hong
YXYi Xu
Yi Xu
XZXiangquan Zheng
Xiangquan Zheng

4 February 2025 in IEEE Transactions on Image Processing
Verified
Journal Article
Closed access
SHSenlong Huang
Senlong Huang
Yongxin GeYongxin Ge
Yongxin Ge
Dongfang LiuDongfang Liu
Dongfang Liu
MHMingjian Hong
Mingjian Hong
JZJunhan Zhao
Junhan Zhao
ALAlexander C. Loui
Alexander C. Loui
Semi-supervised learning based on consistency learning offers significant promise for enhancing medical image segmentation. Current approaches use copy-paste as an effective data perturbation technique to facilitate weak-to-strong consistency learning. However, these techniques often lead to a decrease in the accuracy of synthetic labels corresponding to the synthetic data and introduce excessive perturbations to the distribution of the training data. Such over-perturbation causes the data distribution to stray from its true distribution, thereby impairing the model’s generalization capabilities as it learns the decision boundaries. We propose a weak-to-strong consistency learning framework that integrally addresses these issues with two primary designs: ① it emphasizes the use of highly reliable data to enhance the quality of labels in synthetic datasets through cross-copy-pasting between labeled and unlabeled datasets; ② it employs uncertainty estimation and foreground region constraints to meticulously filter the regions for copy-pasting, thus the copy-paste technique implemented introduces a beneficial perturbation to the training data distribution. Our framework expands the copy-paste method by addressing its inherent limitations, and amplifying the potential of data perturbations for consistency learning. We extensively validated our model using six publicly available medical image segmentation datasets across different diagnostic tasks, including the segmentation of cardiac structures, prostate structures, brain structures, skin lesions, and gastrointestinal polyps. The results demonstrate that our method significantly outperforms state-of-the-art models. For instance, on the PROMISE12 dataset for the prostate structure segmentation task, using only 10% labeled data, our method achieves a 15.31% higher Dice score compared to the baseline models. Our experimental code will be made publicly available at https://github.com/slhuang24/RCP4CL.

24 March 2024 in Proceedings of the AAAI Conference on Artificial Intelligence
Verified
Journal Article
Open access
PDF file
YWYijie Wang
Yijie Wang
MHMingjian Hong
Mingjian Hong
LHLuwen Huangfu
Luwen Huangfu
Sheng HuangSheng Huang
Sheng Huang
In the realm of Zero-Shot Learning (ZSL), we address biases in Generalized Zero-Shot Learning (GZSL) models, which favor seen data. To counter this, we introduce an end-to-end generative GZSL framework called D3GZSL. This framework respects seen and synthesized unseen data as in-distribution and out-of-distribution data, respectively, for a more balanced model. D3GZSL comprises two core modules: in-distribution dual space distillation (ID2SD) and out-of-distribution batch distillation (O2DBD). ID2SD aligns teacher-student outcomes in embedding and label spaces, enhancing learning coherence. O2DBD introduces low-dimensional out-of-distribution representations per batch sample, capturing shared structures between seen and un seen categories. Our approach demonstrates its effectiveness across established GZSL benchmarks, seamlessly integrating into mainstream generative frameworks. Extensive experiments consistently showcase that D3GZSL elevates the performance of existing generative GZSL methods, under scoring its potential to refine zero-shot learning practices. The code is available at: https://github.com/PJBQ/D3GZSL.git

22 September 2023 in IEEE Transactions on Intelligent Transportation Systems
Verified
Journal Article
Closed access
YWYanwen Wu
Yanwen Wu
MHMingjian Hong
Mingjian Hong
ALAo Li
Ao Li
Sheng HuangSheng Huang
Sheng Huang
HLHuijun Liu
Huijun Liu
Yongxin GeYongxin Ge
Yongxin Ge
Pavement distress classification is crucial for the maintenance of highways. Although many methods for classifying pavement distress are available, they all assume that training and testing datasets are drawn from the same distribution. When we introduce a new unlabeled dataset with a different distribution, the performance of existing methods decreases considerably due to domain shift, motivating us to look beyond the supervised setting to utilize unlabeled datasets directly in training a model. Therefore, we develop a novel unsupervised domain adaptation (UDA) framework, namely, the Self-supervised Adversarial Network (SSAN) for the first time in this study to conduct multi-category pavement distress classification on an unlabeled target domain. In particular, SSAN leverages adversarial domain adaptation (ADA) thoughts to align the features of different domains. However, distress typically occupies a small section of high-resolution pavement images. Consequently, aligning features directly is unreasonable because the aligning procedure is still dominated by background features instead of foreground features, which are the most useful information for classification. Therefore, we design a pretext module, called Self-supervised Learning for the Target domain (SLT), to mine foreground information. To validate our method, we use two challenging pavement crack datasets, namely, the Chonqing University Bituminous Pavement Disease Detection (CQU-BPDD) and the Chongqing University Bituminous Pavement Multi-label Disease Detection (CQU-BPMDD) datasets. Moreover, extensive experiments demonstrate that SSAN outperforms state-of-the-art UDA methods.

1 November 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XKXiaohan Kong
Xiaohan Kong
YZYao Min Zhu
Yao Min Zhu
SSSheng Shen
Sheng Shen
JWJiamin Wu
Jiamin Wu
YHYucheng He
Yucheng He
ZXZheng Xu
Zheng Xu
Magnetic resonance imaging (MRI) has proven excellent performance in dental imaging, especially for temporomandibular joint (TMJ), teeth, and periodontal apparatus. However, the high price and strict installation environment of the conventional high-field MRI has prevented its widespread use in dental clinics or developing regions. The introduction of low-cost and portable MRI scanners will help increase the easy accessibility of MRI examination and reduce the patients’ waiting time. This work introduces a low-cost portable 50 mT MRI scanner for dental imaging. First, the overall structure including permanent magnets, gradient coils, and radio-frequency (RF) coils is introduced. The cooling system is removed because the static field is maintained by the permanent magnets. The system stands 90 cm wide, 110 cm high and weighs 600 kg, which makes it possible to install in an average-sized room. Then, the design processes of specialized RF receiving coils for TMJ, teeth are illustrated. In order to improve patient comfort, an intraoral wireless coil for boosting the signal-to-noise ratio (SNR) inside the oral cavity is proposed. Furthermore, the T1-weighted images of TMJ and teeth are given to show the dental imaging performance of the proposed device.