Elizabeth A. Shuman

Elizabeth A. Shuman

Auto-generated profile, based on publicly available information

Elizabeth A. Shuman

Department of Otolaryngology‐Head and Neck Surgery University of Southern California Los Angeles California U.S.A.

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2024 in The Laryngoscope
Verified
Journal Article
Closed access
CMChloe Santa Maria
Chloe Santa Maria
ESElizabeth A. Shuman
Elizabeth A. Shuman
BWBenjamin van der Woerd
Benjamin van der Woerd
CMClare Moffatt
Clare Moffatt
CCCarlos X. Castellanos
Carlos X. Castellanos
MJMichael M. Johns
Michael M. Johns

16 July 2024 in Laryngoscope Investigative Otolaryngology
Verified
Journal Article
Open access
OAOluwatobiloba Ayo‐Ajibola
Oluwatobiloba Ayo‐Ajibola
RDRyan J. Davis
Ryan J. Davis
MLMatthew E. Lin
Matthew E. Lin
NVNeelaysh Vukkadala
Neelaysh Vukkadala
KOKarla O'DEll
Karla O'DEll
ESElizabeth A. Shuman
Elizabeth A. Shuman
Objective: Safe home tracheostomy care requires engagement and troubleshooting by patients, who may turn to online, AI‐generated information sources. This study assessed the quality of ChatGPT responses to such queries.Methods: In this cross‐sectional study, ChatGPT was prompted with 10 hypothetical tracheostomy care questions in three domains (complication management, self‐care advice, and lifestyle adjustment). Responses were graded by four otolaryngologists for appropriateness, accuracy, and overall score. The readability of responses was evaluated using the Flesch Reading Ease (FRE) and Flesch–Kincaid Reading Grade Level (FKRGL). Descriptive statistics and ANOVA testing were performed with statistical significance set to p < .05.Results: On a scale of 1–5, with 5 representing the greatest appropriateness or overall score and a 4‐point scale with 4 representing the highest accuracy, the responses exhibited moderately high appropriateness (mean = 4.10, SD = 0.90), high accuracy (mean = 3.55, SD = 0.50), and moderately high overall scores (mean = 4.02, SD = 0.86). Scoring between response categories (self‐care recommendations, complication recommendations, lifestyle adjustments, and special device considerations) revealed no significant scoring differences. Suboptimal responses lacked nuance and contained incorrect information and recommendations. Readability indicated college and advanced levels for FRE (Mean = 39.5, SD = 7.17) and FKRGL (Mean = 13.1, SD = 1.47), higher than the sixth‐grade level recommended for patient‐targeted resources by the NIH.Conclusion: While ChatGPT‐generated tracheostomy care responses may exhibit acceptable appropriateness, incomplete or misleading information may have dire clinical consequences. Further, inappropriately high reading levels may limit patient comprehension and accessibility. At this point in its technological infancy, AI‐generated information should not be solely relied upon as a direct patient care resource.

7 September 2023 in The Laryngoscope
Verified
Journal Article
Open access
WGWilliam Z Gao
William Z Gao
MPMarcus F Paoletti
Marcus F Paoletti
YBYael Bensoussan
Yael Bensoussan
NBNeel K Bhatt
Neel K Bhatt
ESElizabeth A Shuman
Elizabeth A Shuman
MJMichael M Johns
Michael M Johns
Objective: Vocal fold injection medialization (VFIM) is widely used as an initial treatment for unilateral vocal fold paralysis (UVFP). Current practices employ materials that share the limitation of temporary clinical effect from variable resorption rates. A novel silk protein microparticle‐hyaluronic acid‐based material (silk‐HA) has demonstrated cellular infiltration and tissue deposition that may portend a durable medialization effect. We report on ≥12 months outcomes after VFIM with silk‐HA.Methods: Prospective open‐label study of patients with UVFP that elected treatment with VFIM with silk‐HA. Blinded experts rated laryngeal stroboscopic exams.Results: Seventeen patients with UVFP underwent VFIM with silk‐HA. Twelve of the 17 patients have ≥12 months follow‐up. Seven patients demonstrated durable treatment benefit ≥12 months after injection with median improvement of 19 (p = 0.0156) in VHI‐10. There was no significant change in VHI‐10 between 1 and 12 months for these patients. Blinded ratings indicated that 5/7 patients with sustained improvements in VHI‐10 exhibited complete or touch glottal closure at 12 months. Two of the seven patients exhibited a small (<1 mm) glottal gap at 12 months. Seven patients experienced initial benefit with later regression 3–4 months after injection.Conclusion: VFIM with silk‐HA can offer durable improvement in voice‐related outcomes for UVFP past 12 months. A subset of patients treated with silk‐HA experienced early loss of effect around 3–4 months postinjection. Clinical factors predictive of sustained treatment response to silk‐HA injection require further exploration.Level of Evidence: 3 Laryngoscope, 134:3679–3685, 2024

28 March 2024 in The Laryngoscope
Verified
Journal Article
Closed access
JCJason Shin Chwa
Jason Shin Chwa
ESElizabeth A. Shuman
Elizabeth A. Shuman
KOKarla O'Dell
Karla O'Dell

23 February 2024 in The Laryngoscope
Verified
Journal Article
Closed access
ESElizabeth A. Shuman
Elizabeth A. Shuman
YKYun J. Kim
Yun J. Kim
JRJack Rodman
Jack Rodman
KOKarla O'Dell
Karla O'Dell

10 May 2025 in Laryngoscope Investigative Otolaryngology
Verified
Journal Article
Open access
JCJason Shin Chwa
Jason Shin Chwa
ESElizabeth A. Shuman
Elizabeth A. Shuman
KOKarla O'DEll
Karla O'DEll
Objective: Given the prevalence of post‐intubation acute laryngeal injury (ALgI) and its association with glottic stenosis, greater attention has been placed on the mitigation of modifiable risk factors in patients requiring intubation, notably endotracheal tube (ETT) size. No widely accepted guidelines for adult ETT sizing exist. To better understand how factors driving ETT sizing may differ across specialties, we conducted a survey of faculty Anesthesiologists, Intensivists, and Emergency Medicine (EM) physicians.Methods: An anonymous 14‐question Qualtrics survey was distributed to relevant faculty employed at a single tertiary care institution. Participants completed questions pertaining to their training, ETT sizing preferences, factors considered in decision‐making, and perceived knowledge regarding risk factors of glottic stenosis.Results: A total of 103 complete responses were included, with a response rate of 55.1%. Standard ETT size was reported by 94 (91.3%) respondents to be 7.5 mm or larger in adult males and by 92 (89.3%) respondents to be 7.0 mm or larger in adult females. All respondents preferred a significantly larger ETT size for males compared to females (all p < 0.001). “Need for bronchoscopy” was the most cited factor precluding both males and females from being intubated with a smaller ETT across all specialties. When queried on posterior glottic stenosis, 64 (62.1%) respondents erroneously identified cuff pressure as a risk factor.Conclusions: Understanding ETT sizing among intubating physicians is critical to reducing intubation‐related ALgI. Future laryngologist‐led interventions may be directed toward the adoption of a predominately height‐based model for ETT sizing and education on glottic stenosis.Level of Evidence: 5.