26 March 2018 in IEEE Transactions on Industry Applications
In order to enable voltage ride-through operation, fast and reliable voltage dips detection is necessary. It has been noticed by analysis of huge number of measurement results recorded in-field, in laboratory, and obtained by simulation, that the voltage dips may be characterized by specific low order voltage harmonics pattern which appears at the beginning and at the end of the voltage dips. This feature is named harmonic footprint. The paper proposes a new method of voltage dips detection based on harmonic footprint as part of smart algorithm for detection and classification of power quality events. The aim is to achieve reliable smart voltage dips detection in 1 ms range. Several methods for harmonic estimation in real-time were compared in order to choose the optimal one. The footprint is modeled by mathematical function and applied for voltage dips smart detection using recurrent neural network. The proposed method was tested for voltage dips detection analyzing signals from: 1) Measurement in the real distribution grid (680 records), 2) Computer simulations using IEEE-13 bus test grid and 3) Testing in the laboratory. The reliability (detection rate) and speed of voltage dips detection are tested and verified. Furthermore, the future research directions for presented method are outlined.
28 October 2010 in Phytochemical Analysis
29 November 2018 in IEEE Transactions on Industrial Electronics
Grid condition information extraction is very important for converter control systems in order to perform special functionalities, especially grid support during low voltage ride through (LVRT). As a part of grid condition detection, the voltage sag detection provides information about the start of a fault and obtains indices that determine the behavior of the whole control system of the converter during a fault. Estimation of the magnitude of voltage sag (MoVS) is essential for obtaining proper grid support. This paper presents an algorithm for MoVS (as defined in IEEE Std 1564-2014) prediction. The existence of correlation between magnitudes of a set of low-order harmonics during the transient of voltage PQ events with MoVS is for the first time determined and statistically proved. Correlation is mathematically formulated and the prediction function is obtained on the basis of real grid measurements. Complete algorithm for magnitude prediction is explained, and its possible application in distributed generation control is prese-nted. It is shown that significant time gain is achieved, which may be used as an additional benefit in LVRT operation.
1 January 2018 in Serbian Journal of Electrical Engineering
The paper presents an overview of the electric distribution test grids issued by different technical institutions. They are used for testing different scenarios in operation of a grid for research, benchmarking, comparison and other purposes. Their types, main characteristics, features as well as application possibilities are shown. Recently, these grids are modified with inclusion of distributed generation. An example of modification and application of the IEEE 13-bus for testing effects of faults in cases without and with a distributed generator connection to the grid is presented.