9 October 2020 in IEEE Transactions on Power Electronics
A self-current balancing structure of dual-transformer-based triple-port active bridge (DT-TAB) converter with the reduced component count is proposed in this paper for future sustainable energy system applications. The proposed topology inherits good characteristics of the conventional TAB with even power-sharing in open-loop as a newly added function. It can achieve high power density over the existing TAB converters that possess current-balancing function because the need for an auxiliary magnetic circuit or sophisticated control scheme in equalizing the shared power is eliminated. Besides, the demagnetization and magnetic short-circuit problems associated with the conventional TAB converters that are been eradicated, decoupled power flow management is achieved at all conditions. Moreover, the phase-shift between the input H-bridges gives an additional control degree of freedom that permits the control of output power or offers independent control of voltage magnitude during the reverse power flow. Thereby, extending the system-operating range. The proposed DT-TAB converter has been adapted for two-port operation. All the power switches achieved zero-voltage-switching (ZVS) turn-on. Finally, the robust operation performances of the proposed DT-TAB converter have been verified by the laboratory prototype assembled and tested up to 1-kW. The experimental results presented at the end are proof-of-concept.
22 March 2022 in IEEE Transactions on Industrial Electronics
In this article, two configurations of the quadratic quasi-Z-source (Q-qZS) isolated dc–dc converters are presented, namely continuous input current and discontinuous input current configurations. The operating principles and steady state of the continuous input current topology analyzed in this article is characterized with the following features: 1) wider operating range due to buck and boost functions in a single stage; 2) draws continuous input current; 3) low input current ripple compared with other qZS-based isolated dc–dc converters; 4) better reliability and good immunity against EMI noise; 5) common ground between the input source and the inverting bridge; and 6) continuous control over the entire operating range. Compared with other qZS-based isolated dc–dc converters, lower current stresses on active and passive components used are realized. Hence, the total magnetic volume/energy required by the proposed converter is reduced with the potential of achieving high power density. A prototype of 40–140 V input voltage, 300 V output, and 550 W rated power is developed to validate the performance of the proposed converter presented.
2 December 2021 in IEEE Transactions on Industrial Electronics
A novel beta-quasi-Z-source (β-qZS) converter is proposed for an isolated dc–dc converter with the buck (step-down) and boost (step-up) functions. The β-qZS isolated dc–dc converter addresses the common challenges such as components stresses, reliability, suppression of switch voltage overshoot, size, and power derating in the existing impedance source-based isolated dc–dc converter applications. In addition, the proposed topology dealt with operating duty cycle constraint and loss of duty cycle phenomenon in the Z/qZS galvanically isolated dc–dc converters. This article describes the configuration and provides the principle of operation for the proposed β-qZS converter topology. A laboratory prototype is developed, and the experimental results satisfy the theoretical analysis.
4 January 2023 in IIUM Engineering Journal
The wind speed of a location is a critical parameter for analyzing wind energy conversion systems. Background knowledge has revealed that the two-parameter Weibull distribution is commonly used for fitting wind speed data because of its simplicity, flexibility and suitability. This research study examines wind speed data from five locations in Nigeria (Kano, Maiduguri, Jos, Abuja and Akure). It employs five numerical techniques, namely the maximum likelihood method, method of moment, power density method, empirical method and the logarithmic moment method, to estimate the Weibull parameters based on the locations’ data. The goodness of fit test is used to determine which numerical method best fits the distribution. The paper also considers the techno-economic design of wind electricity of five 25 kW pitch-controlled wind turbines with dissimilar characteristics. The test result presents the method of moment and empirical method as the best methods for calculating the Weibull parameters. Results also show that wind turbine-3 has the least cost of energy and wind turbine-5 has the highest cost of energy. ABSTRAK: Kelajuan angin sesuatu lokasi adalah parameter kritikal bagi menganalisa sistem penukaran tenaga angin. Latar belakang berkaitan telah mendedahkan 2-parameter taburan Weibull (Wbl) lazimnya digunakan bagi memadan data kelajuan angin berdasarkan kesederhanaan, fleksibiliti dan kesesuaian. Kajian penyelidikan ini adalah berkaitan ujian data kelajuan angin pada lima lokasi di Nigeria (Kano, Maiduguri, Jos, Abuja dan Akure). Ia menggunakan lima teknik berangka iaitu kaedah kemungkinan maksimum, kaedah momen, kaedah ketumpatan kuasa, kaedah empirikal dan kaedah momen logaritma bagi menganggar parameter Weibull berdasarkan lokasi data. Ujian kesesuaian digunakan bagi memastikan kaedah berangka adalah padanan paling sesuai bagi taburan. Kajian ini juga turut menimbang reka bentuk tekno-ekonomi elektrik angin bagi lima turbin angin 25 kW kawalan anggul dengan ciri berbeza. Dapatan kajian menunjukkan momen dan kaedah empirikal adalah kaedah terbaik bagi mengira parameter Weibull. Ini menunjukkan bahawa turbin angin-3 mempunyai kos tenaga paling rendah dan turbin angin-5 mempunyai kos tenaga tertinggi.
1 December 2025 in Next Research
SASamson Oladayo Ayanlade
28 November 2024 in IET Power Electronics
This article examines the internal stability of an active clamp forward converter (ACFC) from a non‐linear system and arbitrary changes in the state variable's point of view. The analysis is based on the Lyapunov direct method in conjunction with the operating theory of the ACFC. The equivalent circuit with the state equations is established and their stability is assessed in consideration of the hard‐ and soft‐switching operations using the Lyapunov energy function approach in a piecewise manner. In addition, averaged switch modelling is applied explicitly to derive a more accurate small‐signal model of a low‐side ACFC. The study revealed the presence of a non‐minimum phase problem as the major adverse effect on the stability feature of the ACFC predesigned with soft‐switching capability. The instability of ACFC is related to the magnetising inductance () value (core loss resistance) which influences/determines the hard‐ or soft‐switching operations of the ACFC. Hardware prototype was developed with two different transformers having distinct values of for hard‐ and soft‐switching operations. From the experimental frequency measurement, the model accurately predicts the movement of the complex zeros from the left‐half‐plane (LHP) to the right‐hand‐plane (RHP) as the ACFC changes from the hard‐switching to a soft‐switching operation.