In this paper, Grey Wolf Optimizer (GWO) algorithm is applied to determine optimum switching angles for cascaded multilevel inverter of eliminating some high order harmonics while maintaining the required fundamental voltage. As case study in this paper, 11-level and 15-level inverter are considered and the optimum switching angles are calculated off-line to eliminate the 5th, 7th, 11th, 13th harmonics for the 11-level as well as 17th, 19th harmonics for 15-level. The total harmonic distortion is used to estimate the quality of output voltages. The results are shown graphically for better understanding, the mathematical formulations and simulation results will be presented.
31 December 2020 in IEEE Transactions on Industrial Electronics
This paper presents current-fed (CF) full-bridge (FB) isolated dc-dc converter using quasi-Z-source network. Owing to its inherent buck-boost and clamping function, the proposed converter can effectively eliminate start-up and switch voltage overshoot problems. In addition, when compared with the conventional CF-FB converter with active-clamp, switch current stress is much reduced and less active switches are required. Operation principles of the proposed converter are analyzed in detail. The simulation and experimental results with 1 kW prototype are also provided to verify theoretical analysis.
2 August 2019 in IEEE Transactions on Power Electronics
This paper proposes a new single-phase three-level dual-buck inverter. The topology is derived from a simplified neutral-point clamped inverter that includes fewer active switches. The advantages of the proposed inverter are no shoot-through worries and no reverse recovery issue of the body diode of the power metal-oxide-semiconductor field-effect transistor compared with the conventional inverter; therefore, a high-reliability inverter can be achieved. The operation modes and pulse-width modulation technique are analyzed in detail. Additionally, a switching scheme is proposed to balance and reduce the direct-current-link capacitance. A 1.4-kW prototype was built and tested to validate the theoretical analysis of the proposed converter.
4 August 2021 in IEEE Transactions on Industrial Electronics
This article proposes a single-phase five-level current source inverter with an inductor cell based on the switching-cell (SC) structure. Compared to the conventional inverter, the proposed structure has no open-circuit problem; thus, its reliability is greatly enhanced. The overlap-time inserted in the driving signals can also be minimized to improve the output waveform quality. The proposed inverter's operation is analyzed herein, and the design guideline of SC capacitors is discussed. In addition, the SC extension for the n -level topology is provided. A 1-kW prototype is built and tested to validate the effectiveness of the proposed structure.
3 August 2022 in IEEE Transactions on Industrial Electronics
In this article, a new single-phase five-level current-source inverter is proposed. The proposed inverter provides open/short-circuit immunity and minimizes overlap time by adding four small film capacitors, thus enhancing the inverter's reliability. The efficiency and output waveforms quality are improved due to reduced overlap-time interval. The proposed inverter also provides natural balancing of the inductor currents. In addition, the n switching cells can be used to extend to the proposed N -level inverter. The operating principle, steady-state analysis, fault-state analysis, and parameter selections of the proposed inverter are presented. Furthermore, a comparative study of the proposed inverter and other five-level current-source inverters is addressed. Finally, a 1 kW prototype is implemented to verify the feasibility of the proposed inverter.
2 December 2021 in IEEE Transactions on Industrial Electronics
A novel beta-quasi-Z-source (β-qZS) converter is proposed for an isolated dc–dc converter with the buck (step-down) and boost (step-up) functions. The β-qZS isolated dc–dc converter addresses the common challenges such as components stresses, reliability, suppression of switch voltage overshoot, size, and power derating in the existing impedance source-based isolated dc–dc converter applications. In addition, the proposed topology dealt with operating duty cycle constraint and loss of duty cycle phenomenon in the Z/qZS galvanically isolated dc–dc converters. This article describes the configuration and provides the principle of operation for the proposed β-qZS converter topology. A laboratory prototype is developed, and the experimental results satisfy the theoretical analysis.