Iman Habibagahi

Iman Habibagahi

Auto-generated profile, based on publicly available information

Iman Habibagahi

Department of Electrical Engineering, University of California at Los Angeles, Los Angeles, CA, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
IHIman Habibagahi
Iman Habibagahi
MOMahmoud Omidbeigi
Mahmoud Omidbeigi
JHJoseph Hadaya
Joseph Hadaya
HLHongming Lyu
Hongming Lyu
JJJaeeun Jang
Jaeeun Jang
ABAydin Babakhani
Aydin Babakhani
Neuromodulation of peripheral nerves has been clinically used for a wide range of indications. Wireless and batteryless stimulators offer important capabilities such as no need for reoperation, and extended life compared to their wired counterparts. However, there are challenging trade-offs between the device size and its operating range, which can limit their use. This study aimed to examine the functionality of newly designed wirelessly powered and controlled implants in vagus nerve stimulation for pigs. The implant used near field inductive coupling at 13.56 MHz industrial, scientific, and medical band to harvest power from an external coil. The circular implant had a diameter of 13 mm and weighed 483 mg with cuff electrodes. The efficiency of the inductive link and robustness to distance and misalignment were optimized. As a result, the specific absorption rate was orders of magnitude lower than the safety limit, and the stimulation can be performed using only 0.1 W of external power. For the first time, wireless and batteryless VNS with more than 5 cm operation range was demonstrated in pigs. A total of 84 vagus nerve stimulations (10 s each) have been performed in three adult pigs. In a quantitative comparison of the effectiveness of VNS devices, the efficiency of systems on reducing heart rate was similar in both conventional (75%) and wireless (78.5%) systems. The pulse width and frequency of the stimulation were swept on both systems, and the response for physiological markers was drawn. The results were easily reproducible, and methods used in this study can serve as a basis for future wirelessly powered implants.

6 January 2023 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
IHIman Habibagahi
Iman Habibagahi
JJJaeeun Jang
Jaeeun Jang
ABAydin Babakhani
Aydin Babakhani
This article presents a miniaturized implant with a diameter of only 14 mm, which houses a novel system on chip (SoC) enabling two-voltage-level stimulation of up to 16 implants using a single transmitter (Tx) coil. Each implant can operate at a distance of 80 mm in the air through the inductive resonant link. The SoC consumes only 27- $\mu \text{W}$ static power and enables two channels with stimulation amplitudes of 1.8 and 3.3 V and a timing resolution of 100 $\mu \text{s}$ . The SoC is implemented in the standard 180-nm complementary metal–oxide–semiconductor (CMOS) technology and has an area of $0.75\times1.6$ mm. The SoC comprises an RF rectifier, low dropout regulator (LDO), error detection block, clock data recovery, finite-state machine (FSM), and output stage. Each implant has a printed circuit board (PCB)-defined passcode, which enables the individual addressability of the implants for synchronized therapies. The implantable device weighs only 80 mg and sizes 20.1 mm3. Tolerance of up to 70° to angular misalignment was measured at a distance of 50 mm. The efficacy of bilateral stimulation was further verified by implanting two devices on two sides of a pig’s neck and performing bilateral vagus nerve stimulation (VNS) while monitoring the heart rate.

30 July 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RMRoshan Pathitharayil Mathews
Roshan Pathitharayil Mathews
IHIman Habibagahi
Iman Habibagahi
HSHamid Jafari Sharemi
Hamid Jafari Sharemi
RCRonald Challita
Ronald Challita
SCSteven Cha
Steven Cha
ABAydin Babakhani
Aydin Babakhani
Vagus nerve stimulation (VNS) has been explored as a treatment for a range of conditions, including epilepsy, cardiovascular disorders, drug-resistant depression, chronic pain, and obesity. Conventionally, VNS is administered using an open-loop approach, in which trained personnel adjust stimulation parameters. Medical supervision is necessary to minimize adverse effects, such as severe bradycardia, which can significantly interfere with daily activities. This requirement limits the feasibility of VNS in unsupervised settings and highlights the need for an automated control system. To address this limitation, we introduce the fully automated wireless VNS (FAW-VNS) system, which dynamically adjusts stimulation parameters to maintain steady-state operation while minimizing bradycardia. The FAW-VNS system operates in real-time and consists of a biocompatible, miniaturized, wirelessly powered implant equipped with cuff electrodes; a handheld device for power delivery and stimulation protocol communication; a sensing patch to collect and transmit heart rate (HR) data; and a central control unit (CCU) that updates stimulation protocols based on the acquired physiological signals. In-vivo studies were conducted on four anesthetized pigs to validate the system’s ability to reach a steady-state response, achieving a controlled HR reduction within 2–4% of baseline during stimulation. This work lays the foundation for developing closed-loop, wireless implants for point-of-care applications.

7 November 2022 in IEEE Microwave and Wireless Technology Letters
Verified
Journal Article
Closed access
IHIman Habibagahi
Iman Habibagahi
RMRoshan P. Mathews
Roshan P. Mathews
ARArkaprova Ray
Arkaprova Ray
ABAydin Babakhani
Aydin Babakhani
This letter presents a double-tuned dual input transmitter coil operating at 13.56 and 40.68 MHz industrial, scientific, and medical (ISM) bands for multisite biomedical applications. The proposed system removes the need for two separate coils, which reduces system size and unwanted couplings. The design and analysis of the double-tuned transmitter coil using a lumped element frequency trap are discussed in this letter. The transmitter achieves measured matching of $-$ 26.2 and $-$ 21.5 dB and isolation of $-$ 17.7 and $-$ 11.7 dB at 13.56 and 40.68 MHz, respectively. A 3 $\times$ 15 mm flexible coil is used as an implantable receiver. This letter shows synchronized multisite stimulation of two flexible implants at a distance of 2 cm while covered with 1 cm chicken breast.

8 April 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JJJaeeun Jang
Jaeeun Jang
IHIman Habibagahi
Iman Habibagahi
RMRoshan P. Mathews
Roshan P. Mathews
WGWonseop Gwak
Wonseop Gwak
HRHamed Rahmani
Hamed Rahmani
ABAydin Babakhani
Aydin Babakhani
This article presents a low-power, battery-less biopotential-recording integrated circuit (IC) designed for implantable leadless cardiac monitoring applications, addressing full autonomy based on wireless energy harvesting and closed-loop control. A key technical feature is the closed-loop capability with integration of a dual-band radio frequency (RF) energy harvester and communication system utilizing industrial, scientific, and medical (ISM) bands at 40.68 MHz for downlink and 915 MHz for uplink, ensuring efficient wireless power transfer and robust bidirectional data communication. The RF harvester achieves a peak conversion efficiency exceeding 40%, a critical design challenge in maintaining consistent performance under variable power conditions. Also, the proposed IC overcomes the need for a local oscillator (LO) by utilizing an externally provided clock, reducing system complexity and power consumption. Operating with a clock frequency of 100 kHz, the IC consumes only $8.8~\mu $ W, a major achievement in energy efficiency for wireless, battery-less systems. Fabricated in a 180-nm complementary metaloxidesemiconductor (CMOS) process, the IC successfully demonstrates cardiac signal measurement and heart rate (HR) extraction under a fully battery-less environment with air medium, providing a promising solution for next-generation leadless cardiac monitoring systems.

30 May 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HSHamid Jafari Sharemi
Hamid Jafari Sharemi
IHIman Habibagahi
Iman Habibagahi
RMRoshan P. Mathews
Roshan P. Mathews
ABAydin Babakhani
Aydin Babakhani
This paper presents an innovative dual-mode system as well as design techniques to realize full-duplex data communication and wireless power transfer over a single inductive link. An LC tank implemented on a compact printed circuit board is shared between a rectifier that supplies the batteryless device and a power oscillator that modulates the uplink data in a time division duplex fashion. Designed to operate efficiently in the loose coupling regime, the proposed design ensures reliable performance over a substantial distance and is resilient to interference from the wireless power transfer signal. A miniaturized prototype is implemented on a printed circuit board package with a diameter of 19 mm, which is powered by a 180-nm CMOS chipset. At a data rate of 10 kbps, the coin-sized prototype achieves powering and uplink distances of 140 mm and 110 mm, respectively, offering a fivefold improvement in normalized operating range compared to recent single-coil designs of similar size. The performance of the proposed sensing device is verified by inserting a thick biological tissue between the coils and recording ex-vivo biopotential signals.