Bernd Schäfer

Bernd Schäfer

Auto-generated profile, based on publicly available information

Bernd Schäfer

Laser-Laboratorium Göttingen eV

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2000 in Review of Scientific Instruments
Verified
Journal Article
Closed access
BSBernd Schäfer
Bernd Schäfer
KMKlaus Mann
Klaus Mann
For wave front distribution measurements of excimer laser radiation, a Hartmann–Shack wave front sensor with 40×30 subapertures and a field of view adapted to the lateral laser beam profile was utilized. The peak-to-valley wave front resolution is λ/12 and the dynamic range 100λ per subaperture at 248 nm. Time-averaged propagation characteristics were determined for several combinations of resonator configuration and laser medium from the ns down to the fs pulse length regime. Above that, time-resolved measurements were carried out on a KrF excimer laser, showing a reduction of the beam divergence during the laser pulse by a factor of 1.6. This transient behavior is discussed on the basis of a simple geometrical model. The theoretical results are in qualitative agreement with the experiment.

9 October 2014 in Optics Express
Verified
Journal Article
Closed access
PDF file
MSMartin Stubenvoll
Martin Stubenvoll
BSBernd Schäfer
Bernd Schäfer
KMKlaus Mann
Klaus Mann
We demonstrate the feasibility of passive compensation of the thermal lens effect in fused silica optics, placing suitable optical materials with negative dn/dT in the beam path of a high power near IR fiber laser. Following a brief overview of the involved mechanisms, photo-thermal absorption measurements with a Hartmann-Shack sensor are described, from which coefficients for surface/coating and bulk absorption in various materials are determined. Based on comprehensive knowledge of the 2D wavefront deformations resulting from absorption, passive compensation of thermally induced aberrations in complex optical systems is possible, as illustrated for an F-Theta objective. By means of caustic measurements during high-power operation we are able to demonstrate a 60% reduction of the focal shift in F-Theta lenses through passive compensation.

2 December 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
BSBernd Schäfer
Bernd Schäfer
JGJonas Gloger
Jonas Gloger
ULUwe Leinhos
Uwe Leinhos
KMKlaus Mann
Klaus Mann
A measurement system for quantitative registration of transient and irreversible lens effects in DUV optics induced by absorbed UV laser radiation was developed. It is based upon a strongly improved Hartmann-Shack wavefront sensor with an extreme sensitivity of ~λ/10000 rms @ 193nm, accomplishing precise on-line monitoring of wavefront deformations of a collimated test laser beam transmitted through the laser-irradiated site of a sample. Caused by the temperature dependence of the refractive index as well as thermal expansion, the initially plane wavefront of the test laser is distorted into a convex or concave lens, depending on sign and magnitude of index change and expansion. This transient wavefront distortion yields a quantitative measure of the absorption losses in the sample. In the case of fused silica, an additional permanent change indicates irreversible material compaction. Results for both fused silica and CaF2 are presented and compared.

1 October 2011 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
BSBernd Schäfer
Bernd Schäfer
BFBernhard Flöter
Bernhard Flöter
TMTobias Mey
Tobias Mey
PJPavle Juranic
Pavle Juranic
SKSvea Kapitzki
Svea Kapitzki
KTKai Tiedtke
Kai Tiedtke

27 September 2010 in Optics Express
Verified
Journal Article
Open access
PDF file
BSBernd Schäfer
Bernd Schäfer
MSMatthias Schöneck
Matthias Schöneck
ABArmin Bayer
Armin Bayer
KMKlaus Mann
Klaus Mann
A measurement system for quantitative determination of both surface and bulk contributions to the photo-thermal absorption in DUV optics was developed. It is based upon a Hartmann-Shack wavefront sensor with a sensitivity of ~λ/10000 rms, accomplishing precise on-line monitoring of wavefront deformations of a collimated test laser beam transmitted perpendicular through the excimer laser-irradiated site of a cuboid sample. Caused by the temperature dependence of the refractive index as well as thermal expansion, the initially plane wavefront of the test laser is distorted into a cylindrical shape, with bending ends towards the surface. Sign and magnitude depend on index change and expansion. By comparison with thermal theory, this transient wavefront distortion yields a quantitative absolute measure of bulk and surface absorption losses in the sample. First rresults for fused silica are presented.

16 November 2018
Verified
Conference Paper
Closed access
PDF file
KMKlaus Mann
Klaus Mann
BSBernd Schäfer
Bernd Schäfer
MVMichael Vergöhl
Michael Vergöhl
CBChris Britze
Chris Britze
SBStefan Bruns
Stefan Bruns
JZJennifer Zimara
Jennifer Zimara
In this work the influence of non-uniformity effects on the spectral transmission properties of broad-band dielectric optical coatings was examined. Recently, it was observed that in modern complex dielectric coatings significant spectral, resonantlike errors of the reflected wavefront can occur at specific wavelengths, which are induced by lateral coating nonuniformities [1]. For a detailed investigation of this effect, a setup was developed for monitoring the spectrally dependent wavefront error, utilizing a broad-band monochromatized plasma lamp (spectral range from 400 – 900nm) as light source and a high sensitivity Hartmann-Shack wavefront sensor for detection of reflected or transmitted wavefronts. In addition, a method for absolute and relative calibration of the measured wavefront error is presented. Two broadband dielectric beam splitters (#1 and #2) deposited by magnetron sputtering (high reflectance 400 – 900 nm, high transmittance 920 – 2300 nm) with different coating specifications were analyzed. It could be shown, that for an optimized design the spectral wavefront error can be significantly reduced compared to a standard beam splitter design [2].