Roman Flepp

Roman Flepp

Auto-generated profile, based on publicly available information

Roman Flepp

Department of Pediatric Orthopedics and Traumatology, University Children'S Hospital Zurich, Zurich, Switzerland.

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2025 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
RFRoman Flepp
Roman Flepp
LNLeon Nissen
Leon Nissen
BSBastian Sigrist
Bastian Sigrist
ANArend Nieuwland
Arend Nieuwland
NCNicola Cavalcanti
Nicola Cavalcanti
LCLilian Calvet
Lilian Calvet

22 May 2026 in Medical Image Analysis
Verified
Journal Article
Open access
LWLuohong Wu
Luohong Wu
MSMatthias Seibold
Matthias Seibold
NCNicola A. Cavalcanti
Nicola A. Cavalcanti
YAYunke Ao
Yunke Ao
RFRoman Flepp
Roman Flepp
PFPhilipp Fürnstahl
Philipp Fürnstahl
In computer- and robot-assisted orthopedic surgery (CAOS), patient-specific surgical plans are generated from preoperative medical imaging data to define target locations and implant trajectories. During surgery, these plans must be precisely transferred to the intraoperative setting to guide accurate execution. The accuracy and success of this transfer rely on cross-registration between preoperative and intraoperative data. However, the substantial heterogeneity across imaging modalities and devices renders this registration process challenging and error-prone, leading to inaccuracies. Consequently, more robust and accurate methods for automatic, modality-agnostic multimodal registration of bone surfaces would have a substantial clinical impact. We propose NeuralBoneReg, an instance-specific self-supervised, surface-based framework for bone surface registration using 3D point clouds as an intermediate representation. NeuralBoneReg comprises two key components: an implicit neural unsigned distance field (UDF) module and a multilayer perceptron (MLP)-based registration module. The UDF module learns a neural representation of the preoperative bone model. The registration module solves both global initialization and local refinement by generating a set of transformation hypotheses to register the intraoperative point cloud with the preoperative neural UDF based on a coarse-to-fine strategy. Compared to state-of-the-art (SOTA) supervised registration, NeuralBoneReg operates in an instance-specific self-supervised manner, without requiring inter-subject training data with ground truth transformations. We evaluated NeuralBoneReg against baseline methods on two publicly available multi-modal datasets: a CT-ultrasound dataset of the fibula and tibia (UltraBones100k) and a CT-RGB-D dataset of spinal vertebrae (SpineDepth). The evaluation also includes a newly introduced CT-ultrasound dataset of cadaveric subjects containing femur and pelvis (UltraBonesHip), which will be made publicly available. Quantitative and qualitative results show that NeuralBoneReg achieves competitive performance across anatomies and modalities. On UltraBones100k, it obtains an RRE of 1.83±1.30°, an RTE of 2.02±1.30mm, an RR of 0.89, a CD of 0.82±0.12mm, and an HD95 of 2.06±0.36mm. On UltraBonesHip, it maintains stable performance with an RRE of 1.90±1.56°, an RTE of 2.21±0.86mm, an RR of 0.88, a CD of 2.50±1.08mm, and an HD95 of 8.97±4.08mm, while other methods degrade significantly. On SpineDepth, it achieves an RRE of 3.78±19.34°, an RTE of 2.80±3.75mm, an RR of 0.84, a CD of 1.78±1.61mm, and an HD95 of 4.26±4.58mm. Overall, the method consistently achieves accuracy close to pseudo ground truth across datasets. NeuralBoneReg achieves robust, accurate, and modality-agnostic registration of bone surfaces, offering a promising solution for reliable cross-modal alignment in computer- and robot-assisted orthopedic surgery.

20 June 2026 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
RFRoman Flepp
Roman Flepp
ANArend Nieuwland
Arend Nieuwland
BSBastian Sigrist
Bastian Sigrist
PFPhilipp Fürnstahl
Philipp Fürnstahl
LCLilian Calvet
Lilian Calvet
TDThomas Dreher
Thomas Dreher
Purpose: Accurate execution of preoperative plans in corrective femoral osteotomies remains a substantial challenge. Current techniques are limited by variable accuracy, invasiveness, and substantial radiation exposure, with free-hand methods and patient-specific instrumentation (PSI) often requiring $${>30}$$ > 30 and $${>6}$$ > 6 fluoroscopic images, respectively. This work addresses the need for an accurate navigation system that minimizes dissection and intraoperative fluoroscopy. Methods: We present an integrated, electromagnetic tracking (EMT)-based navigation system for femoral osteotomies. The system couples CT-based preoperative bone planning with one-time intraoperative C-arm calibration and accurate X-ray-to-CT registration, based on two fluoroscopic images acquired at initialization. This registration is followed by real-time, fluoroscopy-free EMT-based navigation of the sawblade, and subsequently of the bone fragments, with respect to the preoperative plan, and is compatible with uniplanar and biplanar osteotomies. Results: In a feasibility study utilizing 18 synthetic femora, EMT guidance significantly outperformed free-hand execution for total angular error ( $$(3.05 \pm 0.75)^\circ $$ ( 3.05 ± 0.75 ) ∘ vs. $$(6.32 \pm 2.36)^\circ $$ ( 6.32 ± 2.36 ) ∘ , $$p=0.031$$ p = 0.031 ). No EMT-guided trials exceeded the $${5}^{\circ }$$ 5 ∘ clinical threshold, whereas free-hand resulted in 4 outliers out of 6 trials while assuming the same full surgical exposure for both techniques. The system achieved statistical equivalence ( $$\pm 2^\circ $$ ± 2 ∘ , $$\pm 2\,\text {mm}$$ ± 2 mm ) to PSI for total angular ( $$p \le 0.02$$ p ≤ 0.02 ) and total translational ( $$p=0.048$$ p = 0.048 ) errors with no significant differences in user questionnaire scores. Conclusion: The proposed EMT-based system enables transfer of preoperative plans to the OR using two fluoroscopic images and provides real-time intraoperative guidance. In a synthetic bone feasibility study, it substantially improved correction accuracy over free-hand execution and achieved equivalent accuracy to PSI, while no additional surgical exposure is needed and requiring substantially fewer fluoroscopic images, motivating subsequent cadaveric and clinical validation.