10 November 2023 in Medical Image Analysis
Established surgical navigation systems for pedicle screw placement have been proven to be accurate, but still reveal limitations in registration or surgical guidance. Registration of preoperative data to the intraoperative anatomy remains a time-consuming, error-prone task that includes exposure to harmful radiation. Surgical guidance through conventional displays has well-known drawbacks, as information cannot be presented in-situ and from the surgeon's perspective. Consequently, radiation-free and more automatic registration methods with subsequent surgeon-centric navigation feedback are desirable. In this work, we present a marker-less approach that automatically solves the registration problem for lumbar spinal fusion surgery in a radiation-free manner. A deep neural network was trained to segment the lumbar spine and simultaneously predict its orientation, yielding an initial pose for preoperative models, which then is refined for each vertebra individually and updated in real-time with GPU acceleration while handling surgeon occlusions. An intuitive surgical guidance is provided thanks to the integration into an augmented reality based navigation system. The registration method was verified on a public dataset with a median of 100% successful registrations, a median target registration error of 2.7 mm, a median screw trajectory error of 1.6°and a median screw entry point error of 2.3 mm. Additionally, the whole pipeline was validated in an ex-vivo surgery, yielding a 100% screw accuracy and a median target registration error of 1.0 mm. Our results meet clinical demands and emphasize the potential of RGB-D data for fully automatic registration approaches in combination with augmented reality guidance.
12 May 2023 in International Journal of Computer Assisted Radiology and Surgery
17 September 2024 in Medical Image Analysis
Spinal fusion surgery requires highly accurate implantation of pedicle screw implants, which must be conducted in critical proximity to vital structures with a limited view of the anatomy. Robotic surgery systems have been proposed to improve placement accuracy. Despite remarkable advances, current robotic systems still lack advanced mechanisms for continuous updating of surgical plans during procedures, which hinders attaining higher levels of robotic autonomy. These systems adhere to conventional rigid registration concepts, relying on the alignment of preoperative planning to the intraoperative anatomy. In this paper, we propose a safe deep reinforcement learning (DRL) planning approach (SafeRPlan) for robotic spine surgery that leverages intraoperative observation for continuous path planning of pedicle screw placement. The main contributions of our method are (1) the capability to ensure safe actions by introducing an uncertainty-aware distance-based safety filter; (2) the ability to compensate for incomplete intraoperative anatomical information, by encoding a-priori knowledge of anatomical structures with neural networks pre-trained on pre-operative images; and (3) the capability to generalize over unseen observation noise thanks to the novel domain randomization techniques. Planning quality was assessed by quantitative comparison with the baseline approaches, gold standard (GS) and qualitative evaluation by expert surgeons. In experiments with human model datasets, our approach was capable of achieving over 5% higher safety rates compared to baseline approaches, even under realistic observation noise. To the best of our knowledge, SafeRPlan is the first safety-aware DRL planning approach specifically designed for robotic spine surgery.
10 May 2025 in Medical Image Analysis
State-of-the-art research of traditional computer vision is increasingly leveraged in the surgical domain. A particular focus in computer-assisted surgery is to replace marker-based tracking systems for instrument localization with pure image-based 6DoF pose estimation using deep-learning methods. However, state-of-the-art single-view pose estimation methods do not yet meet the accuracy required for surgical navigation. In this context, we investigate the benefits of multi-view setups for highly accurate and occlusion-robust 6DoF pose estimation of surgical instruments and derive recommendations for an ideal camera system that addresses the challenges in the operating room. Our contributions are threefold. First, we present a multi-view RGB-D video dataset of ex-vivo spine surgeries, captured with static and head-mounted cameras and including rich annotations for surgeon, instruments, and patient anatomy. Second, we perform an extensive evaluation of three state-of-the-art single-view and multi-view pose estimation methods, analyzing the impact of camera quantities and positioning, limited real-world data, and static, hybrid, or fully mobile camera setups on the pose accuracy, occlusion robustness, and generalizability. Third, we design a multi-camera system for marker-less surgical instrument tracking, achieving an average position error of 1.01mm and orientation error of 0.89° for a surgical drill, and 2.79mm and 3.33° for a screwdriver under optimal conditions. Our results demonstrate that marker-less tracking of surgical instruments is becoming a feasible alternative to existing marker-based systems.
12 December 2024 in Computers in Biology and Medicine
Total Hip Arthroplasty (THA) is a well-established and common orthopedic surgery. Due to the complexity involved in THA, orthopedic surgeons require rigorous training. However, the current gold standard, the tutor-guided and -evaluated apprenticeship model is time-consuming, costly, and poses risks to patients. There is a pressing need for additional training resources to enhance the efficiency and safety of the training process. In this work, we present a novel Augmented Reality (AR)-based simulator designed for THA that helps enable a new self-paced training and learning paradigm without the need for instructors. The simulator reduces the need for instructors by integrating an AR guidance module and an automated performance evaluation module. Three types of AR guidance were developed: Overlay, Virtual Twin, and Sectional Views. A feasibility study was conducted with five resident surgeons and two senior surgeons to compare these guidance methods quantitatively and qualitatively. The automated performance evaluation module was assessed against manual performance evaluation using Bland-Altman analysis with limits of agreement (LoA) and Mann-Whitney U tests. The quantitative feasibility results indicate the efficacy of the developed AR guidance, characterized by mean transitional and rotational deviation errors below 3 mm and 3 degrees. Based on the qualitative results, we provide recommendations for efficient AR guidance designs. The Bland-Altman analysis results (0.22±1.32mm with LoA -2.37 to 2.81 mm for distance deviation, 0.94±2.41 degrees with LoA -3.78 to 5.66 degrees for yaw deviation, -0.34±1.30 degrees with LoA -2.90 to 2.22 degrees for pitch deviation) and p-values of Mann-Whitney U tests (0.64 for distance deviation, 0.12 for yaw deviation, 0.11 for pitch deviation) indicate no statistically significant differences between the automated and manual performance evaluation at a significance level of 0.05. This work shows the potential of AR-based simulators in introducing a novel, data-driven approach to open surgery training in orthopedics, enabling surgeons to individually assess and improve their progress.
26 August 2023 in Artificial Intelligence in Medicine
Pedicle drilling is a complex and critical spinal surgery task. Detecting breach or penetration of the surgical tool to the cortical wall during pilot-hole drilling is essential to avoid damage to vital anatomical structures adjacent to the pedicle, such as the spinal cord, blood vessels, and nerves. Currently, the guidance of pedicle drilling is done using image-guided methods that are radiation intensive and limited to the preoperative information. This work proposes a new radiation-free breach detection algorithm leveraging a non-visual sensor setup in combination with deep learning approach. Multiple vibroacoustic sensors, such as a contact microphone, a free-field microphone, a tri-axial accelerometer, a uni-axial accelerometer, and an optical tracking system were integrated into the setup. Data were collected on four cadaveric human spines, ranging from L5 to T10. An experienced spine surgeon drilled the pedicles relying on optical navigation. A new automatic labeling method based on the tracking data was introduced. Labeled data was subsequently fed to the network in mel-spectrograms, classifying the data into breach and non-breach. Different sensor types, sensor positioning, and their combinations were evaluated. The best results in breach recall for individual sensors could be achieved using contact microphones attached to the dorsal skin (85.8%) and uni-axial accelerometers clamped to the spinous process of the drilled vertebra (81.0%). The best-performing data fusion model combined the latter two sensors with a breach recall of 98%. The proposed method shows the great potential of non-visual sensor fusion for avoiding screw misplacement and accidental bone breaches during pedicle drilling and could be extended to further surgical applications.