1 November 2017 in Molecular Metabolism
Hypothalamic tanycytes are glial cells that line the wall of the third ventricle and contact the cerebrospinal fluid (CSF). While they are known to detect glucose in the CSF we now show that tanycytes also detect amino acids, important nutrients that signal satiety. Ca2+ imaging and ATP biosensing were used to detect tanycyte responses to l-amino acids. The downstream pathway of the responses was determined using ATP receptor antagonists and channel blockers. The receptors were characterized using mice lacking the Tas1r1 gene, as well as an mGluR4 receptor antagonist. Amino acids such as Arg, Lys, and Ala evoke Ca2+ signals in tanycytes and evoke the release of ATP via pannexin 1 and CalHM1, which amplifies the signal via a P2 receptor dependent mechanism. Tanycytes from mice lacking the Tas1r1 gene had diminished responses to lysine and arginine but not alanine. Antagonists of mGluR4 greatly reduced the responses to alanine and lysine. Two receptors previously implicated in taste cells, the Tas1r1/Tas1r3 heterodimer and mGluR4, contribute to the detection of a range of amino acids by tanycytes in CSF.
11 July 2017 in Journal of Materials Chemistry B
Prostate-specific membrane antigen (PSMA), a glycoprotein expressed in the prostatic epithelium endowed with enzymatic activity, is a very promising diagnostic marker for the early detection of prostate cancer. In this study, we report a novel electrochemiluminescence ELISA-like immunosensor based on carbon nanotubes and a highly specific sandwich immunoassay for the PSMA detection. To fabricate the device, an optically transparent electrode was modified with doubly functionalized multi-walled carbon nanotubes carrying amine groups and a monoclonal anti-PSMA antibody. Subsequently, to complete the sandwich immunosensing device, a second specific monoclonal anti-PSMA antibody was labelled with a electrochemiluminescent probe. Under optimized experimental conditions, the proposed sensing device exhibits a performance exceeding that of the state of-the-art in terms of the limit of detection (LOD) and limit of quantification (LOQ) as good as 0.88 ng mL−1 and 2.60 ng mL−1, respectively, in real complex samples such as cell lysates. In addition, the unique role of carbon nanotubes is also discussed by comparison with an analogue sensor assembled without the nanocarbon-based material.
24 August 2017 in ACS Sensors
1 October 2015 in Electrochimica Acta
27 April 2017 in Journal of Materials Chemistry B
C60@lysozyme showed significant visible light-induced singlet oxygen generation in a physiological environment, indicating the potential of this hybrid as an agent for photodynamic therapy.