Yu-Min Wang

Yu-Min Wang

Auto-generated profile, based on publicly available information

Yu-Min Wang

ENN Science and Technology Development Co., Ltd., Langfang 065001, China

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
LZLing Zhang
Ling Zhang
SMShigeru Morita
Shigeru Morita
ZXZong Xu
Zong Xu
ZWZhenwei Wu
Zhenwei Wu
PZPengfei Zhang
Pengfei Zhang
JLJiangang Li
Jiangang Li
A flat-field extreme ultraviolet (EUV) spectrometer working in the 20-500 Å wavelength range with fast time response has been newly developed to measure line emissions from highly ionized tungsten in the Experimental Advanced Superconducting Tokamak (EAST) with a tungsten divertor, while the monitoring of light and medium impurities is also an aim in the present development. A flat-field focal plane for spectral image detection is made by a laminar-type varied-line-spacing concave holographic grating with an angle of incidence of 87°. A back-illuminated charge-coupled device (CCD) with a total size of 26.6 × 6.6 mm2 and pixel numbers of 1024 × 255 (26 × 26 μm2/pixel) is used for recording the focal image of spectral lines. An excellent spectral resolution of Δλ0 = 3-4 pixels, where Δλ0 is defined as full width at the foot position of a spectral line, is obtained at the 80-400 Å wavelength range after careful adjustment of the grating and CCD positions. The high signal readout rate of the CCD can improve the temporal resolution of time-resolved spectra when the CCD is operated in the full vertical binning mode. It is usually operated at 5 ms per frame. If the vertical size of the CCD is reduced with a narrow slit, the time response becomes faster. The high-time response in the spectral measurement therefore makes possible a variety of spectroscopic studies, e.g., impurity behavior in long pulse discharges with edge-localized mode bursts. An absolute intensity calibration of the EUV spectrometer is also carried out with a technique using the EUV bremsstrahlung continuum at 20-150 Å for quantitative data analysis. Thus, the high-time resolution tungsten spectra have been successfully observed with good spectral resolution using the present EUV spectrometer system. Typical tungsten spectra in the EUV wavelength range observed from EAST discharges are presented with absolute intensity and spectral identification.

1 June 2024 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
MLMin-Sheng Liu
Min-Sheng Liu
HXHua-Sheng Xie
Hua-Sheng Xie
YWYu-Min Wang
Yu-Min Wang
JDJia-Qi Dong
Jia-Qi Dong
KFKai-Ming Feng
Kai-Ming Feng
HZHan-Yue Zhao
Han-Yue Zhao
ENN Science and Technology Development Co., Ltd. (ENN) is committed to generating fusion energy in an environmentally friendly and cost-effective manner, which requires abundant aneutronic fuel. Proton-boron (p-11B or p-B) fusion is considered an ideal choice for this purpose. Recent studies have suggested that p-B fusion, although challenging, is feasible based on new cross section data, provided that a hot ion mode and high wall reflection can be achieved to reduce electron radiation loss. The high beta and good confinement of the spherical torus (ST) make it an ideal candidate for p-B fusion. By utilizing the new spherical torus energy confinement scaling law, a reactor with a major radius R0=4 m, central magnetic field B0=6 T, central temperature Ti0=150 keV, plasma current Ip=30 MA, and hot ion mode Ti/Te=4 can yield p-B fusion with Q>10. A roadmap for p-B fusion has been developed, with the next-generation device named EHL-2. EHL stands for ENN He-Long, which literally means “peaceful Chinese Loong.” The main target parameters include R0≃1.05 m, A≃1.85, B0≃3 T, Ti0≃30 keV, Ip≃3 MA, and Ti/Te≥2. The existing ST device EXL-50 was simultaneously upgraded to provide experimental support for the new roadmap, involving the installation and upgrading of the central solenoid, vacuum chamber, and magnetic systems. The construction of the upgraded ST fusion device, EXL-50U, was completed at the end of 2023, and it achieved its first plasma in January 2024. The construction of EHL-2 is estimated to be completed by 2026.

1 November 2019 in Fusion Engineering and Design
Verified
Journal Article
Closed access
YWY.M. Wang
Y.M. Wang
TZT. Zhang
T. Zhang
Xiaoming LiuXiaoming Liu
Xiaoming Liu
CZC.W. Zhao
C.W. Zhao
HQH. Qu
H. Qu
XGXiang Gao
Xiang Gao

17 July 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
HXH. M. Xiang
H. M. Xiang
TZT. Zhang
T. Zhang
FWF. Wen
F. Wen
HQH. Qu
H. Qu
MWM. F. Wu
M. F. Wu
XGXiang Gao
Xiang Gao
An ordinary-mode polarized multi-channel correlation reflectometer has been developed on the Experimental Advanced Superconducting Tokamak (EAST). The system with four different probing frequencies (i.e., 20.4 GHz, 24.8 GHz, 33 GHz, and 40 GHz) and two poloidally spaced receiving antennas can realize both the radial correlation measurement and the poloidal correlation measurement. These diagnostics focus on the measurement of density fluctuation in the pedestal region to investigate the turbulence transport and H-mode physics on EAST. In this article, the system hardware design, the key component tests, and the system performance are shown in detail.

1 January 2019 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
PSP. J. Sun
P. J. Sun
YLY. D. Li
Y. D. Li
YRY. Ren
Y. Ren
XZX. D. Zhang
X. D. Zhang
GWG. J. Wu
G. J. Wu
JLJ. G. Li
J. G. Li
A quasi-coherent mode (QCM) was measured by the tangential CO2 laser collective scattering diagnostic at high plasma electron density during both enhanced Dα/small edge-localized mode (ELM) and ELM-free H mode phases in Experimental Advanced Superconducting Tokamak (EAST). Experimental results from only local oscillator CO2 laser scattering prove that the QCM is measured by the scattering diagnostic in the far-forward mode. The driven QCM density fluctuation ( k ⊥ < 3 cm−1) and magnetic fluctuation suggest that the QCM is an electromagnetic mode. The typical frequency of the QCM is f ≈ 26.5 kHz. A combination analysis of scattering signals and Mirnov signals suggests that the QCM has toroidal mode number n ≈ 17 and rotates along with the electron diamagnetic drift velocity direction in the lab frame. The analysis of Mirnov and reflectometer signals supports that the QCM locates in the edge pedestal region. The QCM power has been found to be related to both the Dα signal and the pedestal density gradient. A comparison of the EAST QCM and C-Mod quasi-coherent mode has been given in detail.

1 May 2019 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
JCJingbo Chen
Jingbo Chen
ZYZhongshi Yang
Zhongshi Yang
DCDavid Peter Coster
David Peter Coster
KLKedong Li
Kedong Li
KWKai Wu
Kai Wu
ETEast Team
East Team
Both experimental modeling and numerical modeling were carried out on Experimental Advanced Superconductive Tokamak (EAST) to study the radiative divertor plasma behavior with neon (Ne) seeding. Steady H-mode radiation feedback control regimes (frad ∼ 18%–36%) were achieved by synergistic working of a divertor puff and supersonic molecular beam injection with Ne in the 2017 EAST campaign. Ne seeding effectively promoted divertor detachment while only causing a slight loss to the plasma stored energy in the experiment. To better understand the experimental result, analysis of the detachment process is introduced in this work. Two time slices namely before and after Ne seeding during the radiative divertor experiment in Shot #71021 were simulated by Scrape Off Layer Plasma Simulator (SOLPS)-ITER code. The simulation results for upstream plasma agreed well with the experiment, and the divertor profile agreed well on the outer targets when ignoring drifts. Radiation distribution was also calculated by SOLPS-ITER, showing that there was a high radiation region near the X-point, which is consistent with the experimental measurements.