Oleksandr Pryimak

Oleksandr Pryimak

Auto-generated profile, based on publicly available information

Oleksandr Pryimak

Kyiv National University of Construction and Architecture

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2024
Verified
Book Chapter
Closed access
PDF file
PPPavlo Pasichnyk
Pavlo Pasichnyk
OPOleksandr Pryimak
Oleksandr Pryimak
OPOleksandr Pohosov
Oleksandr Pohosov
YKYevhen Kulinko
Yevhen Kulinko
BKBohdan Koziachyna
Bohdan Koziachyna

26 October 2023
Verified
Book Chapter
Closed access
PDF file
SSStepan Shapoval
Stepan Shapoval
VZVasyl Zhelykh
Vasyl Zhelykh
OPOleksandr Pryimak
Oleksandr Pryimak
BGBogdan Gulai
Bogdan Gulai

9 August 2024
Verified
Book Chapter
Closed access
PDF file
BGBogdan Gulai
Bogdan Gulai
SSStepan Shapoval
Stepan Shapoval
OPOleksandr Pryimak
Oleksandr Pryimak
VZVasyl Zhelykh
Vasyl Zhelykh
HKHanna Klymenko
Hanna Klymenko

11 February 2024 in Ventilation, Illumination and Heat Gas Supply
Verified
Journal Article
Open access
PDF file
LMLiubov Makarenko
Liubov Makarenko
OPOleksandr Priymak
Oleksandr Priymak
In the context of a constant increase in air pollution, the question arises of creating safe air zones with quality control of the air environment in places where people stay. The constant deterioration of air quality caused by military operations and their consequences, as well as the need to reduce the consumption of available energy resources, requires studying the recommendations on the optimal air exchange rate of existing European and American air quality requirements in residential and office buildings to achieve the required air quality with minimal energy consumption. The objectives of the study were to obtain data on the efficiency of air purification in a given volume at different air exchange rates. A separate task was to check the data declared by the manufacturer on the pressure drop across the filter with an increase in the volume of air passing through it. CleanZone5300 filtration systems with F9 class filter and HEPA H12/13 class filter were considered, which can provide an air exchange rate of 2 to 10 times. In a room volume of 225.9 m3, at a temperature of 18 ˚C, a relative humidity of 57-59 % and an initial number of particles in the room air of 533,440 particles/ft3 (15105 particles/m3), the ability of filtration units to purify the air at different rates was studied. It was concluded that even with a factor of 2, the filtration system can provide air purification up to 40 % when using the F9 filter and up to 60 % when using the HEPA H12/13 filter in a short period of time. Recirculation filter units are considered as the easiest way to increase the air exchange rate in the room, in our climatic conditions. With the possibility of avoiding the processing of air for heating or cooling when using outside atmospheric air. In the installations used in the study, the electrical power consumption of the fans is 300 W per hour. The conclusions of the study need to be tested in office premises with an existing ventilation system to determine the optimal multiplicity of achieving a given air quality when using filters or portable filter units.

25 December 2025 in Ventilation, Illumination and Heat Gas Supply
Verified
Journal Article
Open access
OPOleksandr Pryimak
Oleksandr Pryimak
IKIvan Kripak
Ivan Kripak
The growth of technological progress leads to continuous improvement not only of enclosing structures, but also of engineering life support systems. Any building in the cold season constantly loses internal thermal energy from the heating system due to the transfer of heat from the warmer internal environment of the premises to the colder outside air. Heat losses through enclosing structures and the negative contribution of each of its elements are specific to each building. However, in the vast majority of cases, the greatest heat losses occur in translucent enclosing structures (windows). Such elements are the objects of scientific research in greater numbers. The global increase in the cost of energy carriers and the need to reduce greenhouse gas emissions stimulate the development of systems that combine functionality and environmental friendliness. The “heat-generating window” offers a promising approach to ensuring the energy efficiency of buildings that meets the needs of modern society. The introduction of this type of structure can help optimize the distribution of heat flows and reduce overall heat losses by external building enclosures. Analysis and deep understanding of heat balances in such a system is the basis for its effective implementation and expansion of the scope of application. This design, combining the main functions of a translucent enclosing structure (as the most vulnerable, in terms of heat loss, element of the enclosure) with elements of heating and air conditioning systems, can significantly increase the energy efficiency of windows, but, at the same time, requires a new approach to determining the level of energy efficiency of such a system. The purpose of this work is to obtain and analyze key indicators of energy efficiency of a heat-generating window based on traditional thermophysical parameters. The following criteria are proposed for use: the light transmittance of the window structure, taking into account the coating of the glass with a film photovoltaic surface; assessment of the efficiency of heat flow distribution in the system; the efficiency of the translucent photovoltaic surface; the coefficient of conversion of electrical energy into generated thermal power (COP).

30 October 2026 in Ventilation, Illumination and Heat Gas Supply
Verified
Journal Article
Open access
OPOleksandr Pryimak
Oleksandr Pryimak
IKIvan Kripak
Ivan Kripak
This study establishes a methodological approach for evaluating the energy efficiency indicators of a translucent building envelope component—featuring an integrated air-to-air heat pump and photovoltaic coating—while accounting for changing climatic parameters. This structural element combines the primary function of a translucent envelope (providing natural interior lighting) with the additional functions of heat generation and electricity production. Its integration with heating and air conditioning systems can enhance the energy efficiency of various types of premises and buildings as a whole. Achieving specified indoor microclimate parameters requires a rational combination of the heat-generating window's structural and functional features with heating and air conditioning technologies.The proposed methodology for evaluating the multi-factor energy efficiency indicators of the heat-generating window is based on a regression analysis of the interactions between controllable, monitored, and uncontrollable experimental factors. Accounting for their mutual influence improves the reliability of the assessment, reduces the volume of experimental measurements of thermophysical quantities required, and enables the determination of optimal structural and functional parameters for the design under study. The heat-generating window is considered as a multifactor system. A linear-in-parameters regression structure containing the main effects and pairwise interactions of the five factors is proposed. The factors are represented in coded form to provide a dimensionless coordinate system and to enable comparison of the regression coefficients. The proposed procedure includes experimental identification of the regression coefficients, assessment of their statistical significance, residual and lack-of-fit analysis, and verification of model adequacy.After experimental identification and validation, the resulting regression models can be used to predict the energy, thermal and exergy characteristics of the heat-generating window within the investigated factor space.