Zhengjia Wu

Zhengjia Wu

Auto-generated profile, based on publicly available information

Zhengjia Wu

Kunming Dongchuan District Construction Project Quality and Safety Supervision and Management Station, Kunming 654100, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2026 in Infrastructures
Verified
Journal Article
Open access
PDF file
ZWZhanjing Wu
Zhanjing Wu
ZTZhong Tao
Zhong Tao
LZLongfei Zhang
Longfei Zhang
ZWZhengjia Wu
Zhengjia Wu
QHQiang Huang
Qiang Huang
HSHaisu Sun
Haisu Sun
To investigate the influence of isolation-layer eccentricity on the torsional response of step-terrace mountain (STM) structures, a 1:10 scaled reinforced concrete model was designed and tested using shaking table experiments. Both isolated and non-isolated configurations were considered, and different eccentricity levels were achieved by adjusting the bearing layouts in the upper and lower isolation layers. The torsional response was evaluated in terms of torsional angle, torsional displacement ratio, and relative torsional effect. The results indicate that the non-isolated STM structure exhibits pronounced torsional amplification and progressive damage accumulation. Deformation and damage are concentrated in the upper stories and dropped-story region, eventually leading to a stiffness–degradation–dominated failure pattern. In contrast, the STM isolated structure effectively suppresses torsional response, and inter-story rotations remain small and relatively uniform along the height, indicating that seismic deformation is primarily redistributed within the isolation layers rather than amplified in the superstructure. The experimental results further demonstrate that torsional behavior is governed by the coupling effect between isolation-layer eccentricity and seismic input direction. The eccentricity in the upper isolation layer plays the dominant role in triggering torsional amplification, while simultaneous eccentricities in both isolation layers produce a cumulative torsional effect. When the eccentricity of the isolation layers is controlled within 5%, the torsional displacement ratio remains below 1.2, while the non-isolated structure reaches values exceeding the code limit of 1.5. In addition, slope-direction excitation intensifies absolute torsional deformation due to overturning effects induced by elevation differences. These findings highlight that torsional response in STM isolated systems is controlled by the interaction between vertical irregularity and isolation-system asymmetry.

2 July 2024 in Buildings
Verified
Journal Article
Open access
PDF file
LZLongfei Zhang
Longfei Zhang
LXLAN Xiang
LAN Xiang
WYWenzheng Yu
Wenzheng Yu
KWKeChuan Wu
KeChuan Wu
ZTZhong Tao
Zhong Tao
WPWen Pan
Wen Pan
With the installation of rubber isolation bearings in the upper and lower ground layers, an isolated step-terrace structure was created. Considering the ultimate bearing capacity of the rubber bearing under tension as the critical condition, a comprehensive framework was established to evaluate the overturning failure mechanisms present in isolated step-terrace structures. The bound of nominal aspect ratio was identified as the principal control index within this framework, which incorporates critical parameters such as height ratio (α), width ratio (β), vertical tensile stiffness to compressive stiffness ratio (γ), seismic coefficient (k), and nominal vertical compressive stress (σ0) to provide a thorough analysis of the structural responses and potential failure scenarios. In order to further investigate this matter, a scaled model of an isolated step-terrace concrete frame structure featuring two dropped layers and a single span within an 8° seismic fortification zone was meticulously crafted at a 1:10 similarity ratio. Subsequently, a series of shaking table tests were conducted to analyze the structural response under seismic excitation. The findings indicate that: utilizing the bound of nominal aspect ratio as a metric to gauge the anti-overturning capacity of isolated step-terrace structures is a justified approach. In instances where the height ratio remains constant, the bound of nominal aspect ratio for both positive and negative overturning trended upward with an increase in the width ratio. Notably, the bound of nominal aspect ratio for positive overturning consistently registered lower values compared to that of the negative overturning, underscoring the heightened susceptibility of step-terrace structures to positive overturning. Moreover, in scenarios characterized by higher height and width ratios, the structural integrity remained unscathed by any overturning effects arising from insufficient tensile strength in rubber bearings. Furthermore, the bound of nominal aspect ratio exhibited an ascending trend as the seismic coefficient, nominal vertical compressive stress, and vertical tensile stiffness to compressive stiffness ratio decreased. The outcomes derived from the shaking table test not only confirm the impressive seismic performance of the structure, but also, by closely examining the instantaneous stress variations within the upper and lower isolation layers of the model, substantiate the existence of a positive overturning hazard in scenarios marked by higher seismic coefficients (k). This observation aligns seamlessly with the theoretical projections, thereby substantiating the efficacy of the structural overturning failure theory through direct empirical verification.