Mateusz Granat

Mateusz Granat

Auto-generated profile, based on publicly available information

Mateusz Granat

Pomeranian Medical University in Szczecin

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in BioMed Research International
Verified
Journal Article
Open access
PDF file
MGMateusz Granat
Mateusz Granat
JCJanusz Cieloszyk
Janusz Cieloszyk
UKUrszula Kowalska
Urszula Kowalska
JBJadwiga Buczkowska-Radlińska
Jadwiga Buczkowska-Radlińska
RŁRyta Łagocka
Ryta Łagocka
Objectives. The aim of the study was to determine the quantitative and qualitative surface structure of contemporary RBCs in posterior teeth reconstructions: regular viscosity bulk fill and conventional composites, obtained after two‐stage polishing procedure. Materials and Methods. Four conventional nanohybrid composites (Tetric EvoCeram, GrandioSO, Filtek Z550, and Ceram·X Mono) and four regular viscosity bulk fill composites (Tetric EvoCeram Bulk Fill, X‐tra fil, Filtek Bulk Fill Posterior, and QuixFil) were tested. Samples of each RBC were prepared using PMMA cylindrical mold. After two‐step polishing procedure, a surface geometry was evaluated under profilometry (Turbowave v. 7.36, Hommel‐Etamic) and SEM (VEGA 3, Tescan Analytics). To evaluate differences between values, the following nonparametric tests were used: Friedman’s ANOVA, Wilcoxon’s matched‐pair test, ANOVA Kruskal‐Wallis, and Mann‐Whitney U. Results. All conventional RBCs showed Ra values in the range of 0.20‐0.26 μm. Bulk fill showed higher values in range of 0.49‐1.36 μm except for Filtek Bulk Fill Posterior, which achieved 0.23 μm Ra value. SEM images of conventional RBCs were described as smooth surfaces with slight damage except for TEC, which presented smooth surface with no damage. Bulk fill composites showed rough surface, except for TBF, which presented smooth surface with slight damage. Conclusions. Regular viscosity bulk fill composites do not constitute a homogeneous group regarding surface roughness after polishing. They obtain, for the most part, poorer smoothness values after polishing than conventional RBCs.

11 December 2023 in Pomeranian Journal of Life Sciences
Verified
Journal Article
Open access
PDF file
RŁRyta Łagocka
Ryta Łagocka
MGMateusz Granat
Mateusz Granat
KLKatarzyna Lewusz-Butkiewicz
Katarzyna Lewusz-Butkiewicz
MTMałgorzata Tomasik
Małgorzata Tomasik
MLMariusz Lipski
Mariusz Lipski
Introduction: The aim of this study was to investigate the effect of thermal cycling on the surface geometry of high-viscosity bulk-fill resin-based composites (RBCs) compared to conventional nanohybrid composites.Materials and methods: Four conventional nanohybrid composites (Tetric EvoCeram – TEC, GrandioSO – GD, Filtek Z550 – FZ, and Ceram·X Mono – CX) and 4 high-viscosity bulk-fill composites (Tetric EvoCeram Bulk Fill – TBF, X-tra fil – XF, Filtek Bulk Fill Posterior – FBF, and QuixFil – QF) were tested. After the 2-step polishing procedure, the samples were divided into 2 groups: control group (K) and thermal cycling group (TC). Samples from the TC were subjected to thermal cycling according to ISO 11405 (THE-1100, SD Mechatronik GmbH). Surface geometry was evaluated by profilometry (Turbowave v. 7.36, Hommel-Etamic) and scanning electron microscope – SEM (VEGA 3, Tescan Analytics).Results: The applied thermal cycles increased the surface roughness of conventional RBCs: TEC (p = 0.000007), GD (p = 0.04), and CX (p = 0.0005). A reduction in the surface roughness of bulk-fill composites was observed in the case of materials: XF (p = 0.000003) and QF (p = 0.0002). Thermal cycling was shown to alter the surface roughness of the TEC, CX, XF, and QF materials. Conclusion: The application of thermal cycling in a water environment in accordance with the ISO 11405 standard causes the degradation of the organic matrix and the exposure of filler molecules on the surface of both conventional and high-viscosity bulk-fill composites. Some of the tested RBCs, especially those containing modern hydrophobic monomers, are less susceptible to these processes.

29 August 2022 in Farmacja Polska
Verified
Journal Article
Open access
RŁRyta Łagocka
Ryta Łagocka
MRMarta Rogocka
Marta Rogocka
MGMateusz Granat
Mateusz Granat
KJKatarzyna Jakubowska
Katarzyna Jakubowska
APAndrzej Pawlik
Andrzej Pawlik
MMMałgorzata Mazurek-Mochol
Małgorzata Mazurek-Mochol